MRI denoising using Non-Local Means
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676 · cited 1×
“Gaussian filters have been largely used in some applications such as fMRI (Ashburner and Friston, 2000) but they have the disadvantage of blurring edges by averaging pixels with non-similar patterns.”
MethodBilateral Filtering for Gray and Color Images
Tomasi, C., & Manduchi, R. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710815 · Cited by 8,177 · cited 2×
“More recently, the trilateral filter (Wong and Chung, 2004), an evolution of the bilateral filter (Tomasi and Manduchi, 1998), has been proposed to take into account local structure in addition to intensity and geometric features.”
BackgroundA Review of Image Denoising Algorithms, with a New One
Buades, A., Coll, B., & Morel, J. M. (2005) · Multiscale Modeling & Simulation · doi:10.1137/040616024 · Cited by 4,083
SUSAN—a new approach to low level image processing
Smith, S. M., & Brady, J. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007963824710 · Cited by 3,333 · cited 1×
“Some filters, like the SUSAN (Smith and Brady, 1997) or the bilateral filters are based in the same principle.”
BackgroundNonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
Wavelet-based Rician noise removal for magnetic resonance imaging
Nowak, R. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.791966 · Cited by 620
A versatile wavelet domain noise filtration technique for medical imaging
Pizurica, A., Philips, W., Lemahieu, I., & Acheroy, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809588 · Cited by 531
Cited by
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Adaptive non‐local means denoising of MR images with spatially varying noise levels
Manjón, J. V., Coupé, P., Martí‐Bonmatí, L., Collins, D. L., & Robles, M. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22003 · Cited by 1,082
Self-citationMIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Ten Years of BrainAGE as a Neuroimaging Biomarker of Brain Aging: What Insights Have We Gained?
Franke, K., & Gaser, C. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00789 · Cited by 604
BEaST: Brain extraction based on nonlocal segmentation technique
Eskildsen, S. F., Coupé, P., Fonov, V., Manjón, J. V., Leung, K. K., Guizard, N., Wassef, S. N., Østergaard, L. R., & Collins, D. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.012 · Cited by 472
Image Denoising Methods. A New Nonlocal Principle
Buades, A., Coll, B., & Morel, J. M. (2010) · SIAM Review · doi:10.1137/090773908 · Cited by 442
Group-Sparse Representation With Dictionary Learning for Medical Image Denoising and Fusion
Li, S., Yin, H., & Fang, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217493 · Cited by 385
Lemaître, G., Martí, R., Freixenet, J., Vilanova, J. C., Walker, P. M., & Meriaudeau, F. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.02.009 · Cited by 348
Qu, X., Hou, Y., Lam, F., Guo, D., Zhong, J., & Chen, Z. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.09.007 · Cited by 340
A review on medical image denoising algorithms
Mohd Sagheer, S. V., & George, S. N. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102036 · Cited by 316
A survey on the magnetic resonance image denoising methods
Mohan, J., Krishnaveni, V., & Guo, Y. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.007 · Cited by 295
Wiest-Daesslé, N., Prima, S., Coupé, P., Morrissey, S. P., & Barillot, C. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-85990-1_21 · Cited by 276
Manjón, J. V., Coupé, P., Buades, A., Fonov, V., Louis Collins, D., & Robles, M. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.010 · Cited by 271
Self-citationNew methods for MRI denoising based on sparseness and self-similarity
Manjón, J. V., Coupé, P., Buades, A., Louis Collins, D., & Robles, M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.04.003 · Cited by 271
Self-citationNoise-Driven Anisotropic Diffusion Filtering of MRI
Krissian, K., & Aja-Fernandez, S. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2025553 · Cited by 229
Chen, Z., Pawar, K., Ekanayake, M., Pain, C., Zhong, S., & Egan, G. F. (2022) · Journal of Digital Imaging · doi:10.1007/s10278-022-00721-9 · Cited by 224
“…experimental study of brain MRI scans from five healthy volunteers that compared performance between three deep learning-based denoising methods, namely, denoising convolutional neural network (DnCNN), a shrinkage convolutional neural network (SCNN), and deep learning-based reduction (dDLR) [98].”
BackgroundNon-local statistical label fusion for multi-atlas segmentation
Asman, A. J., & Landman, B. A. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.10.002 · Cited by 217
“The non-local means framework has emerged in the context of image de-noising (Buades et al., 2005; Coupé et al., 2006; Kervrann et al., 2007; Liu et al., 2008; Manjón et al., 2008; Van De Ville and Kocher, 2009).”
BackgroundContent-Noise Complementary Learning for Medical Image Denoising
Geng, M., Meng, X., Yu, J., Zhu, L., Jin, L., Jiang, Z., Qiu, B., Li, H., Kong, H., Yuan, J., et al. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3113365 · Cited by 183
Moradmand, H., Aghamiri, S. M. R., & Ghaderi, R. (2020) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12795 · Cited by 173
Ran, M., Hu, J., Chen, Y., Chen, H., Sun, H., Zhou, J., & Zhang, Y. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.05.001 · Cited by 169
Multiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 168
Denoising of Dynamic Contrast-Enhanced MR Images Using Dynamic Nonlocal Means
Gal, Y., Mehnert, A. J. H., Bradley, A. P., McMahon, K., Kennedy, D., & Crozier, S. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2026575 · Cited by 78
“Several different levels of simulated Rician noise were imposed [ 34 ] on these images as shown in thefirst column of Table I. The MAV estimator was found to yield biased, although linearly related, estimates”
Method
Metadata
- Authors
- MANJON, J., CARBONELLCABALLERO, J., LULL, J., GARCIAMARTI, G., MARTIBONMATI, L., & ROBLES, M.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 12
- Issue
- 4
- Pages
- 514-523
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2073660032
- Cited by
- 575
- References
- 15
- FWCI
- 24.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.