The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Consistent landmark and intensity-based image registration
Abstract
Two new consistent image registration algorithms are presented: one is based on matching corresponding landmarks and the other is based on matching both landmark and intensity information. The consistent landmark and intensity registration algorithm produces good correspondences between images near landmark locations by matching corresponding landmarks and away from landmark locations by matching the image intensities. In contrast to similar unidirectional algorithms, these new consistent algorithms jointly estimate the forward and reverse transformation between two images while minimizing the inverse consistency error-the error between the forward (reverse) transformation and the inverse of the the reverse (forward) transformation. This reduces the ambiguous correspondence between the forward and reverse transformations associated with large inverse consistency errors. In both algorithms a thin-plate spline (TPS) model is used to regularize the estimated transformations. Two-dimensional (2-D) examples are presented that show the inverse consistency error produced by the traditional unidirectional landmark TPS algorithm can be relatively large and that this error is minimized using the consistent landmark algorithm. Results using 2-D magnetic resonance imaging data are presented that demonstrate that using landmark and intensity information together produce better correspondence between medical images than using either landmarks or intensity information alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Research works printed but not linked: 36
- Bookstein, 1978, Lecture Notes in Biomathematics, 24
- 10.1017/cbo9780511573064 · DOI · Paper page
- 10.1038/jcbfm.1988.92 · DOI · Paper page
- 10.1007/3-540-48714-X_19 · DOI
- 10.1109/42.481446 · DOI · Paper page
- 10.1016/B978-012692535-7/50090-2 · doi:10.1016/b978-012692535-7/50090-2
- 10.1097/00004728-198901000-00004 · DOI · Paper page
- 10.1109/42.511745 · DOI · Paper page
- 10.1117/12.348618 · doi:10.1117/12.348618
- 10.1016/B978-012692535-7/50091-4 · DOI
- 10.1016/S0734-189X(89)80014-3 · DOI · Paper page
- 10.1097/00004728-199307000-00004 · DOI · Paper page
- 10.1073/pnas.90.24.11944 · DOI · Paper page
- 10.1109/83.536892 · DOI · Paper page
- 10.1137/0915014 · DOI · Paper page
- Gee, 1995, Probabilistic matching of brain images, 3, 113
- 10.1097/00004728-199801000-00027 · DOI · Paper page
- 10.1016/B978-012692535-7/50078-1 · DOI
- 10.1006/nimg.1999.0437 · DOI · Paper page
- Dryden, 1998, Statistical Shape Analysis
- 10.1016/B978-012692535-7/50086-0 · doi:10.1016/b978-012692535-7/50086-0
- Kent, 1994, The link between kriging and thin-plate splines
- 10.1117/12.216420 · DOI
- 10.1117/12.131082 · doi:10.1117/12.131082
- Joshi, 1997, Large deformation diffeomorphisms and gaussian random fields for statistical characterization of brain sub-manifolds
- 10.1016/B978-012692535-7/50083-5 · DOI
- 10.1109/83.855431 · DOI · Paper page
- 10.1109/42.650882 · DOI · Paper page
- Kybic, 2001, Elastic image registration using parametric deformation models
- 10.1007/3-540-48714-X_17 · DOI
- Johnson, 2000, Method for consistent linear-elastic medical image registration
- 10.1109/42.932742 · DOI · Paper page
- Talairach, 1988, Co-Planar Stereotactic Atlas of the Human Brain
- 10.1090/qam/1668732 · DOI · Paper page
- Toga, 1999, Academic
- Johnson, 2000, Image registration methods for the synthesis and evaluation of anatomical population summaries
Cited by
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citationDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Johnson and Christensen’s consistent registration approach [379] as well as Rueckert et al.”
BackgroundMethodTransMorph: Transformer for unsupervised medical image registration
Chen, J., Frey, E. C., He, Y., Segars, W. P., Li, Y., & Du, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102615 · Cited by 804
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Integrating spatial configuration into heatmap regression based CNNs for landmark localization
Payer, C., Štern, D., Bischof, H., & Urschler, M. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.007 · Cited by 365
Metadata
- Authors
- Johnson, H. J., & Christensen, G. E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-05
- Volume
- 21
- Issue
- 5
- Pages
- 450-461
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2146497006
- Cited by
- 399
- References
- 2
- FWCI
- 18.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Consistent landmark and intensity-based image registration. https://app.cochat.ai/papers/10.1109/tmi.2002.1009381
- The paper
- Johnson, H. J., & Christensen, G. E. (2002). Consistent landmark and intensity-based image registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.1009381
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.