Comparison of lithium-ion battery performance at beginning-of-life and end-of-life

Stroe, A.-I., Knap, V., Stroe, D.-I. · 2018 · Microelectronics Reliability
Cited by 52

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In this paper, a comparison between the performance of a Lithium-ion battery at beginning-of-life (BOL) and at two increased degradation levels is presented. The capacity, internal resistance, and open circuit voltage of a 13 Ah high-power Lithium-ion battery had been measured at BOL for different temperatures, C-rates, and state-of-charge (SOC) levels. Then, two battery cells were aged at two different cycle aging conditions until they lost 40% and 60% of their initial capacity, respectively. At that moment, the two battery cells were removed from the aging processes and were subjected to characterization measurements similar to the ones performed at BOL. The obtained results shown that besides the expected capacity fade and internal resistance increase, there is a dramatic change in the variation of the battery performance parameters with the temperature, C-rate, and/or SOC, between a fresh cell and the two heavily degraded cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.microrel.2018.07.077

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Stroe, A.-I., Knap, V., & Stroe, D.-I.
Venue
Microelectronics Reliability
Publisher
Elsevier BV
Published
2018-09
Volume
88-90
Pages
1251-1255
ISSN
0026-2714 (ISSN-L)
OpenAlex
W2893171393
Cited by
52
References
3
FWCI
3.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.