The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vitro and in vivo evaluation of SU-8 biocompatibility
Open accessAbstract
SU-8 negative photoresist is a high tensile strength polymer that has been used for a number of biomedical applications that include cell encapsulation and neuronal probes. Chemically, SU-8 comprises, among other components, an epoxy based monomer and antimony salts, the latter being a potential source of cytotoxicity. We report on the in vitro and in vivo evaluation of SU-8 biocompatibility based on leachates from various solvents, at varying temperature and pH, and upon subcutaneous implantation of SU-8 substrates in mice. MTT cell viability assay did not exhibit any cytotoxic effects from the leachates. The hemolytic activity of SU-8 is comparable to that of FDA approved implant materials such as silicone elastomer, Buna-S and medical steel. In vivo histocompatibility study in mice indicates a muted immune response to subcutaneous SU-8 implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Cited by
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
3D printing of functional microrobots
Li, J., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01062f · Cited by 303
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
Metadata
- Authors
- Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A., & Gimi, B.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2013-10
- Volume
- 33
- Issue
- 7
- Pages
- 4453-4459
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W1986364032
- Cited by
- 262
- References
- 1
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro and in vivo evaluation of SU-8 biocompatibility. https://app.cochat.ai/papers/10.1016/j.msec.2013.07.001
- The paper
- Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A., & Gimi, B. (2013). In vitro and in vivo evaluation of SU-8 biocompatibility. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2013.07.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.