CoChat

Syringe-injectable mesh electronics integrate seamlessly with minimal chronic immune response in the brain

Open access
Zhou, Tao, Hong, Guosong, Fu, Tian-Ming, Yang, Xiao, Schuhmann, Thomas G., Viveros, Robert D., Lieber, Charles M. · 2017 · Proceedings of the National Academy of Sciences

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Significance: Seamless integration of electrical probes within neural tissue could substantially enhance their impact and open up new opportunities in neuroscience research through electronic therapeutics. This paper describes systematic studies of brain tissue behavior following implantation of a design for probes that can be precisely targeted to specific brain regions by syringe injection as in many biological species and have an ultraflexible open mesh structure similar to brain tissue itself. Studies of the chronic tissue response postimplantation demonstrate that these tissue-like probes do not elicit inflammation or scarring, in contrast to more conventional probes. Moreover, neurons were found to penetrate through the probes’ open mesh structure, thus demonstrating an unprecedented level of integration and compatibility with the brain circuitry.

Overview

Integrity signals

Registry

Crossref · 10.1073/pnas.1705509114

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 44 references

Research works printed but not linked: 1

  1. PS Steif Mechanics of Materials (Pearson, Upper Saddle River, NJ, 2012).

Cited by

See all 227

Metadata

Authors
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M.
Affiliations
  • Harvard University (US)
  • Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138;
Venue
Proceedings of the National Academy of Sciences
Published
2017-05-22
Volume
114
Issue
23
Pages
5894-5899
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2620547429
Cited by
227
References
44
Citations by year
2026: 22 · 2025: 14 · 2024: 20 · 2023: 23 · 2022: 18 · 2021: 45 · 2020: 29 · 2019: 32 · 2018: 14 · 2017: 9
FWCI
11.25
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Fidelity Investments | Fidelity Biosciences (A25744)
  • American Heart Association (16POST27250219)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
gliosis, astrocytes, microglia, histology
MeSH terms
Animals, Brain, Brain Mapping, Electrodes, Implanted, Male, Mice, Inbred C57BL, Microscopy, Fluorescence, Syringes, Mice, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Syringe-injectable mesh electronics integrate seamlessly with minimal chronic immune response in the brain. https://app.cochat.ai/papers/10.1073/pnas.1705509114
The paper
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017). Syringe-injectable mesh electronics integrate seamlessly with minimal chronic immune response in the brain. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1705509114

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.