Cited by 245Innovative Energy Harvesting TechnologiesAdvanced Sensor and Energy Harvesting MaterialsFerroelectric and Piezoelectric Materials

In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters

Open access
Kim, Dong Hyun, Shin, Hong Ju, Lee, Hyunseung, Jeong, Chang Kyu, Park, Hyewon, Hwang, Geon‐Tae, Lee, Ho‐Yong, Joe, Daniel J. +5 more·2017·Advanced Functional Materials

Abstract

Additional surgeries for implantable biomedical devices are inevitable to replace discharged batteries, but repeated surgeries can be a risk to patients, causing bleeding, inflammation, and infection. Therefore, developing self‐powered implantable devices is essential to reduce the patient's physical/psychological pain and financial burden. Although wireless communication plays a critical role in implantable biomedical devices that contain the function of data transmitting, it has never been integrated with in vivo piezoelectric self‐powered system due to its high‐level power consumption (microwatt‐scale). Here, wireless communication, which is essential for a ubiquitous healthcare system, is successfully driven with in vivo energy harvesting enabled by high‐performance single‐crystalline (1 − x)Pb(Mg 1/3 Nb 2/3)O 3−(x)Pb(Zr,Ti)O 3 (PMN‐PZT). The PMN‐PZT energy harvester generates an open‐circuit voltage of 17.8 V and a short‐circuit current of 1.74 µA from porcine heartbeats, which are greater by a factor of 4.45 and 17.5 than those of previously reported in vivo piezoelectric energy harvesting. The energy harvester exhibits excellent biocompatibility, which implies the possibility for applying the device to biomedical applications.

Integrity signals

Registry

Crossref · 10.1002/adfm.201700341

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., Kim, J., Joung, B., & Lee, K. J.
Affiliations
  • Korea Advanced Institute of Science and Technology (KR)
  • Chungbuk National University (KR)
  • Department of Electrical Engineering and Computer Science Seoul National University 1 Gwanak‐ro Gwanak‐gu Seoul 08826 Republic of Korea
  • Yonsei University (KR)
  • Korea Institute of Materials Science (KR)
  • Seoul National University (KR)
Corresponding author
  • Kim, Jaeha
  • Joung, Boyoung
  • Lee, Keon Jae
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2017-05-11
Volume
27
Issue
25
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2612312025
Cited by
245
References
45
Citations by year
2026: 10 · 2025: 27 · 2024: 30 · 2023: 24 · 2022: 30 · 2021: 32 · 2020: 30 · 2019: 30 · 2018: 28 · 2017: 3
FWCI
19.34
Type
journal article
Language
en
Open access
Locations
  • Advanced Functional Materials (publishedVersion)
  • YUHSpace (Yonsei University Medical Library) (submittedVersion, cc-by-nc-nd)
Funders
  • Ministry of Science, ICT and Future Planning
  • National Research Foundation of Korea (2016M3A7B4910636, 2016R1A5A1009926)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
Keywords
piezoelectric energy harvester, PMN-PT single crystal, biomedical implants, open-circuit voltage, short-circuit current, battery-free devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›