Abstract
INTRODUCTION During the past decade, increased efforts have been made to develop alternative management options instead of dialysis and homograft renal transplantation for end-stage renal disease. State-of-the-art methods employ tissue engineering to produce natural acellular scaffolds that could resolve the concern of allograft rejection and obviate the need for immunosuppressive therapy. Complete decellularization of kidney with intact extracellular matrix is crucial for in vivo compatibility and success of transplantation. Herein, we evaluate the efficacy of two different whole organ decellularization protocols, vasculature integrity, and in vivo transplantation of sheep kidneys. MATERIALS AND METHODS Eight sheep kidneys were decellularized by perfusion-based method utilizing two different protocols (Protocol 1: 1% Triton X-100 and 0.5% SDS vs. Protocol 2: 1% SDS). The samples were evaluated by histopathology in terms of decellularization and extracellular matrix preservation. Computerized tomography angiography was performed to evaluate vasculature. Subsequently, both methods were transplanted in four sheep and monitored for vascular integrity and extravasations in short-term. RESULTS Scaffolds obtained from both protocols were entirely decellularized. However; the extracellular matrix was better preserved in protocol 1 compared to protocol 2. In addition, the vascular integrity was intact in decellularized scaffolds treated with Triton X-100 plus SDS (protocol 1). After transplantation, the samples treated with protocol 2 showed extravasation of fluid in the interstitial space while the samples treated with protocol 1 showed intact extracellular matrix and vasculature. CONCLUSIONS This study demonstrated the efficacy of well-preserved acellular scaffold and vasculature network in post renal transplant outcome in a sheep model. These results have potential to pave the road for further investigations in acellular whole organ transplantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An overview of tissue and whole organ decellularization processes
Crapo, P. M., Gilbert, T. W., & Badylak, S. F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.057 · Cited by 3,591
Decellularization of tissues and organs
Gilbert, T. W., Sellaro, T. L., & Badylak, S. F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.014 · Cited by 2,222
Extracellular matrix as a biological scaffold material: Structure and function
BADYLAK, S., FREYTES, D., & GILBERT, T. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.09.013 · Cited by 1,671
SELF-REGULATION OF GROWTH IN THREE DIMENSIONS
Folkman, J., & Hochberg, M. (1973) · The Journal of Experimental Medicine · doi:10.1084/jem.138.4.745 · Cited by 829
Xenogeneic extracellular matrix as a scaffold for tissue reconstruction
Badylak, S. F. (2004) · Transplant Immunology · doi:10.1016/j.trim.2003.12.016 · Cited by 747
The use of whole organ decellularization for the generation of a vascularized liver organoid
Baptista, P. M., Siddiqui, M. M., Lozier, G., Rodriguez, S. R., Atala, A., & Soker, S. (2011) · Hepatology · doi:10.1002/hep.24067 · Cited by 681
Organ engineering based on decellularized matrix scaffolds
Song, J. J., & Ott, H. C. (2011) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2011.03.005 · Cited by 501
Orlando, G., Farney, A. C., Iskandar, S. S., Mirmalek-Sani, S.-H., Sullivan, D. C., Moran, E., AbouShwareb, T., De Coppi, P., Wood, K. J., Stratta, R. J., et al. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e31825a02ab · Cited by 229
Sabetkish, S., Kajbafzadeh, A.-M., Sabetkish, N., Khorramirouz, R., Akbarzadeh, A., Seyedian, S. L., Pasalar, P., Orangian, S., Beigi, R. S. H., Aryan, Z., et al. (2015) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35291 · Cited by 152
Self-citation
Cited by
Zhang, X., Chen, X., Hong, H., Hu, R., Liu, J., & Liu, C. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.09.014 · Cited by 680
Neishabouri, A., Soltani Khaboushan, A., Daghigh, F., Kajbafzadeh, A.-M., & Majidi Zolbin, M. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.805299 · Cited by 281
Self-citationLarge Animal Models in Regenerative Medicine and Tissue Engineering: To Do or Not to Do
Ribitsch, I., Baptista, P. M., Lange-Consiglio, A., Melotti, L., Patruno, M., Jenner, F., Schnabl-Feichter, E., Dutton, L. C., Connolly, D. J., van Steenbeek, F. G., et al. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00972 · Cited by 249
Golebiowska, A. A., Intravaia, J. T., Sathe, V. M., Kumbar, S. G., & Nukavarapu, S. P. (2024) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.09.017 · Cited by 236
“In a recent study, decellularization of sheep kidneys was performed by perfusion of Triton X-100 in combination with SDS or SDS only [133].”
MethodDecellularization for the retention of tissue niches
Moffat, D., Ye, K., & Jin, S. (2022) · Journal of Tissue Engineering · doi:10.1177/20417314221101151 · Cited by 152
Strategies for decellularization, re-cellularization and crosslinking in liver bioengineering
Wang, J., & Jin, X. (2024) · The International Journal of Artificial Organs · doi:10.1177/03913988231218566 · Cited by 3
Metadata
- Authors
- Kajbafzadeh, A.-M., Khorramirouz, R., Nabavizadeh, B., Ladi Seyedian, S.-S., Akbarzadeh, A., Heidari, R., Masoumi, A., Azizi, B., & Seyed Hossein Beigi, R.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 98
- Pages
- 392-400
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2907545141
- Cited by
- 48
- References
- 9
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.