The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Self-powered cardiac pacemaker by piezoelectric polymer nanogenerator implant
Open accessAbstract
Abstract Self-powered biomedical implants improve the life of patients and lower the risks associated with battery replacement. Piezoelectric energy harvesters that generate electricity from the cardiac motions are among the potential candidates to be used in self-powered implants, such as cardiac pacemakers. In this context, lead-based ceramic piezoelectric nanogenerators (PNGs) were emerged, which are toxic and susceptible to fatigue crack, causing harm to the patients. Polyvinylidene fluoride-trifluoroethylene (PVDF-TrFE)-based films were also developed as cardiac energy harvesters. Here, we show a battery-free heart pacemaker that is powered by the generated electricity of a biocompatible and flexible piezoelectric polymer-based nanogenerator (PNG) from the cardiac motions of the left ventricle. The PNG is comprised of composite nanofibers of poly(vinylidene fluoride) (PVDF) and a hybrid nanofiller made of zinc oxide (ZnO) and reduced graphene oxide (rGO). The composite nanofiber is optimized towards achieving a large power output. In vivo implanted optimized PNG can successfully harvest 0.487 μJ from every heartbeat, which is conveniently larger than the pacing threshold energy for the human heart. The successful demonstration of a self-powered pacemaker places the polymer-based PNGs among the viable candidates for self-powered biomedical implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
Cited by
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Piezoelectric energy harvesting systems for biomedical applications
Panda, S., Hajra, S., Mistewicz, K., In-na, P., Sahu, M., Rajaitha, P. M., & Kim, H. J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107514 · Cited by 269
A review on polymers and their composites for flexible electronics
Li, L., Han, L., Hu, H., & Zhang, R. (2023) · Materials Advances · doi:10.1039/d2ma00940d · Cited by 256
Metadata
- Authors
- Azimi, S., Golabchi, A., Nekookar, A., Rabbani, S., Amiri, M. H., Asadi, K., & Abolhasani, M. M.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 83
- Pages
- 105781
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3119529004
- Cited by
- 243
- References
- 5
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-powered cardiac pacemaker by piezoelectric polymer nanogenerator implant. https://app.cochat.ai/papers/10.1016/j.nanoen.2021.105781
- The paper
- Azimi, S., Golabchi, A., Nekookar, A., Rabbani, S., Amiri, M. H., Asadi, K., & Abolhasani, M. M. (2021). Self-powered cardiac pacemaker by piezoelectric polymer nanogenerator implant. Nano Energy. https://doi.org/10.1016/j.nanoen.2021.105781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.