From brain to movement: Wearables-based motion intention prediction across the human nervous system
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Fueled by the recent proliferation of energy-efficient and energy-autonomous or self-powered nanotechnology-based wearable smart systems, human motion intention prediction (MIP) plays a critical role in a wide range of applications, such as rehabilitation and assistive robotics, to enable more natural, biologically inspired, and seamless integrated motion assistance task execution, including for elders and physically impaired patients. With the increasing complexity of human-machine interactions and the need for personalized assistance, there is a growing demand for real-time and accurate MIP systems. This review aims to provide a comprehensive understanding of the interdisciplinary field of MIP, under the logic of its physiological foundations, by discussing state-of-the-art sensing technologies, including brain-computer interfaces (BCI), electromyography (EMG), and motion sensors, alongside the relevant data processing techniques and decoding algorithms. We emphasize the importance of fostering collaboration among scholars from different domains to capture the intricate dependencies between the set of stimuli and responses of the central nervous system and the activation of the complex set of muscles and joints that produce human motion. By offering insights into the recent advancements and future prospects of the field, this review seeks to stimulate further research and innovation in the rapidly evolving area of human motion intention prediction, for a future where technologies understand and respond to complex human intentions patterns, anticipating their needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weiss, K., Khoshgoftaar, T. M., & Wang, D. (2016) · Journal of Big Data · doi:10.1186/s40537-016-0043-6 · Cited by 6,260
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
The false hope of current approaches to explainable artificial intelligence in health care
Ghassemi, M., Oakden-Rayner, L., & Beam, A. L. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00208-9 · Cited by 1,724
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Translational Applications of Hydrogels
Correa, S., Grosskopf, A. K., Lopez Hernandez, H., Chan, D., Yu, A. C., Stapleton, L. M., & Appel, E. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01177 · Cited by 1,143
Human volition: towards a neuroscience of will
Haggard, P. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2497 · Cited by 1,134
Nanotechnology‐Enabled Energy Harvesting for Self‐Powered Micro‐/Nanosystems
Wang, Z. L., & Wu, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201656 · Cited by 1,063
Explainable AI: A Brief Survey on History, Research Areas, Approaches and Challenges
Xu, F., Uszkoreit, H., Du, Y., Fan, W., Zhao, D., & Zhu, J. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-32236-6_51 · Cited by 758
Deep Learning for Sensor-based Human Activity Recognition
Chen, K., Zhang, D., Yao, L., Guo, B., Yu, Z., & Liu, Y. (2022) · ACM Computing Surveys · doi:10.1145/3447744 · Cited by 690
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
Wen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Ramanujam, E., Perumal, T., & Padmavathi, S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3069927 · Cited by 455
A universal interface for plug-and-play assembly of stretchable devices
Jiang, Y., Ji, S., Sun, J., Huang, J., Li, Y., Zou, G., Salim, T., Wang, C., Li, W., Jin, H., et al. (2023) · Nature · doi:10.1038/s41586-022-05579-z · Cited by 422
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
A parietal-premotor network for movement intention and motor awareness
Desmurget, M., & Sirigu, A. (2009) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2009.08.001 · Cited by 370
Deep Learning for Sensor-based Human Activity Recognition: Overview, Challenges and Opportunities
Chen, K., Zhang, D., Yao, L., Guo, B., Yu, Z., & Liu, Y. (2020) · arXiv · doi:10.48550/arxiv.2001.07416 · Cited by 314
Multilayered electronic transfer tattoo that can enable the crease amplification effect
Tang, L., Shang, J., & Jiang, X. (2021) · Science Advances · doi:10.1126/sciadv.abe3778 · Cited by 231
EMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton
Yin, Y. H., Fan, Y. J., & Xu, L. D. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2178034 · Cited by 197
A substrate-less nanomesh receptor with meta-learning for rapid hand task recognition
Kim, K. K., Kim, M., Pyun, K., Kim, J., Min, J., Koh, S., Root, S. E., Kim, J., Nguyen, B.-N. T., Nishio, Y., et al. (2022) · Nature Electronics · doi:10.1038/s41928-022-00888-7 · Cited by 175
Shin, J. H., Kwon, J., Kim, J. U., Ryu, H., Ok, J., Joon Kwon, S., Park, H., & Kim, T.-I. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00164-w · Cited by 123
Engineering the Comfort‐of‐Wear for Next Generation Wearables
Shimura, T., Sato, S., Zalar, P., & Matsuhisa, N. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202200512 · Cited by 86
Adaptive predictive systems applied to gait analysis: A systematic review
Caldas, R., Fadel, T., Buarque, F., & Markert, B. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.01.021 · Cited by 50
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
Self-citationLee, H., Lee, G., Lee, S., & Ahn, C. R. (2022) · Automation in Construction · doi:10.1016/j.autcon.2022.104253 · Cited by 31
Dey, S., & Schilling, A. F. (2023) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2022.3158935 · Cited by 27
Cited by
Abidi, M. H. (2024) · Scientific Reports · doi:10.1038/s41598-024-82624-z · Cited by 20
Liang, X., Sheng, L., & Cai, J. (2025) · Advanced Engineering Informatics · doi:10.1016/j.aei.2025.103591 · Cited by 8
Metadata
- Authors
- Tang, C., Xu, Z., Occhipinti, E., Yi, W., Xu, M., Kumar, S., Virk, G. S., Gao, S., & Occhipinti, L. G.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2023-10
- Volume
- 115
- Pages
- 108712
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W4384700931
- Cited by
- 61
- References
- 25
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.