The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Fast and robust parameter estimation for statistical partial volume models in brain MRI
Abstract
Due to the finite spatial resolution of imaging devices, a single voxel in a medical image may be composed of mixture of tissue types, an effect known as partial volume effect (PVE). Partial volume estimation, that is, the estimation of the amount of each tissue type within each voxel, has received considerable interest in recent years. Much of this work has been focused on the mixel model, a statistical model of PVE. We propose a novel trimmed minimum covariance determinant (TMCD) method for the estimation of the parameters of the mixel PVE model. In this method, each voxel is first labeled according to the most dominant tissue type. Voxels that are prone to PVE are removed from this labeled set, following which robust location estimators with high breakdown points are used to estimate the mean and the covariance of each tissue class. Comparisons between different methods for parameter estimation based on classified images as well as expectation--maximization-like (EM-like) procedure for simultaneous parameter and partial volume estimation are reported. The robust estimators based on a pruned classification as presented here are shown to perform well even if the initial classification is of poor quality. The results obtained are comparable to those obtained using the EM-like procedure, but require considerably less computation time. Segmentation results of real data based on partial volume estimation are also reported. In addition to considering the parameter estimation problem, we discuss differences between different approximations to the complete mixel model. In summary, the proposed TMCD method allows for the accurate, robust, and efficient estimation of partial volume model parameters, which is crucial to a variety of brain MRI data analysis procedures such as the accurate estimation of tissue volumes and the accurate delineation of the cortical surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.
Geman, S., & Geman, D. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767596 · Cited by 17,949
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Robust Regression and Outlier Detection
Piepel, G. F. (1989) · Technometrics · doi:10.1080/00401706.1989.10488524 · Cited by 6,144
Spatial Interaction and the Statistical Analysis of Lattice Systems
Besag, J. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00999.x · Cited by 6,067
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 3×
“Preprocessing steps included the correction of the intensity inhomogeneity where necessary ( Sled et al., 1998 ) and the classification into hard labels (WM, GM, and CSF) by a neural network classifier that was trained automatically using SPAMs (Kollokian, 1996).(Theclassifierusedwasastandardbackpropagationartificial…”
MethodInfluentialSelf-citationOn the Statistical Analysis of Dirty Pictures
Besag, J. (1986) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1986.tb01412.x · Cited by 4,191
Least Median of Squares Regression
Rousseeuw, P. J. (1984) · Journal of the American Statistical Association · doi:10.1080/01621459.1984.10477105 · Cited by 3,835
A Fast Algorithm for the Minimum Covariance Determinant Estimator
Rousseeuw, P. J., & Driessen, K. V. (1999) · Technometrics · doi:10.1080/00401706.1999.10485670 · Cited by 2,708
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Self-citation(1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056181 · Cited by 1,577
Huber, P. J. (1997) · Springer Series in Statistics · doi:10.1007/978-1-4612-0667-5_6 · Cited by 1,551
A Monte Carlo Implementation of the EM Algorithm and the Poor Man's Data Augmentation Algorithms
Wei, G. C. G., & Tanner, M. A. (1990) · Journal of the American Statistical Association · doi:10.1080/01621459.1990.10474930 · Cited by 1,453
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Magnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950
Correction for partial volume effects in PET: principle and validation.
ROUSSET, O. G., Ma, Y., & Evans, A. C. (1998) · PubMed · Cited by 919
Self-citationAutomated 3-D Extraction of Inner and Outer Surfaces of Cerebral Cortex from MRI
MacDonald, D., Kabani, N., Avis, D., & Evans, A. C. (2000) · NeuroImage · doi:10.1006/nimg.1999.0534 · Cited by 850
Self-citationAdaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805
MRI simulation-based evaluation of image-processing and classification methods
Kwan, R. K.-S., Evans, A. C., & Pike, G. B. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816072 · Cited by 709
Self-citationChoosing a Point from the Surface of a Sphere
Marsaglia, G. (1972) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177692644 · Cited by 673
Robust Statistics-The Approach Based on Influence Functions.
Law, J., Hampel, F. R., Ronchetti, E. M., Rousseeuw, P. J., & Stahel, W. A. (1986) · The Statistician · doi:10.2307/2987975 · Cited by 392
Segmentation and measurement of the cortex from 3-D MR images using coupled-surfaces propagation
Zeng, X., Staib, L. H., Schultz, R. T., & Duncan, J. S. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811276 · Cited by 320
Partial volume tissue classification of multichannel magnetic resonance images-a mixel model
Choi, H. S., Haynor, D. R., & Kim, Y. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97590 · Cited by 282
A unifying framework for partial volume segmentation of brain MR images
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806587 · Cited by 281
ANIMAL+INSECT: Improved Cortical Structure Segmentation
Collins, D. L., Zijdenbos, A. P., Baaré, W. F. C., & Evans, A. C. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_16 · Cited by 253
Self-citationAn accurate and efficient Bayesian method for automatic segmentation of brain MRI
Marroquin, J. L., Vemuri, B. C., Botello, S., Calderon, E., & Fernandez-Bouzas, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803119 · Cited by 251
Estimation of the partial volume effect in MRI
GONZALEZBALLESTER, M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00061-0 · Cited by 217
Reconstruction of the human cerebral cortex from magnetic resonance images
Xu, C., Pham, D. L., Rettmann, M. E., Yu, D. N., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.781013 · Cited by 216
Model-based 3-D segmentation of multiple sclerosis lesions in magnetic resonance brain images
Kamber, M., Shinghal, R., Collins, D. L., Francis, G. S., & Evans, A. C. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414608 · Cited by 211
Self-citationPartial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms
Laidlaw, D. H., Fleischer, K. W., & Barr, A. H. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668696 · Cited by 188
Probability and Statistics for the Engineering, Computing, and Physical Sciences
Waller, R. A., & Dougherty, E. R. (1992) · Technometrics · doi:10.2307/1269263 · Cited by 181
Brain tissue classification of magnetic resonance images using partial volume modeling
Ruan, S., Jaggi, C., Xue, J., Fadili, J. M., & Bloyet, D. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897810 · Cited by 147
Spatial classification using fuzzy membership models
Kent, J. T., & Mardia, K. V. (1988) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.6774 · Cited by 136
Statistical models of partial volume effect
Santago, P., & Gage, H. D. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.469934 · Cited by 100
Optimization of functions with many minima
Bilbro, G. L., & Snyder, W. E. (1991) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/21.108301 · Cited by 89
Segmentation and measurement of brain structures in MRI including confidence bounds
Ballester, M. Á. G., Zisserman, A., & Brady, M. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00013-x · Cited by 52
Kollokian, V. (1996) · Spectrum Research Repository (Concordia University) · Cited by 41
Cited by
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290
Self-citationCAT: a computational anatomy toolbox for the analysis of structural MRI data
Gaser, C., Dahnke, R., Thompson, P. M., Kurth, F., Luders, E., & Initiative, T. A. D. N. (2024) · GigaScience · doi:10.1093/gigascience/giae049 · Cited by 1,281
Wildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
An automated tool for detection of FLAIR-hyperintense white-matter lesions in Multiple Sclerosis
Schmidt, P., Gaser, C., Arsic, M., Buck, D., Förschler, A., Berthele, A., Hoshi, M., Ilg, R., Schmid, V. J., Zimmer, C., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.032 · Cited by 1,223
Metadata
- Authors
- Tohka, J., Zijdenbos, A., & Evans, A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2004-09
- Volume
- 23
- Issue
- 1
- Pages
- 84-97
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2153480371
- Cited by
- 670
- References
- 40
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.