Identifying reliable independent components via split-half comparisons
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Independent component analysis (ICA) is a family of unsupervised learning algorithms that have proven useful for the analysis of the electroencephalogram (EEG) and magnetoencephalogram (MEG). ICA decomposes an EEG/MEG data set into a basis of maximally temporally independent components (ICs) that are learned from the data. As with any statistic, a concern with using ICA is the degree to which the estimated ICs are reliable. An IC may not be reliable if ICA was trained on insufficient data, if ICA training was stopped prematurely or at a local minimum (for some algorithms), or if multiple global minima were present. Consequently, evidence of ICA reliability is critical for the credibility of ICA results. In this paper, we present a new algorithm for assessing the reliability of ICs based on applying ICA separately to split-halves of a data set. This algorithm improves upon existing methods in that it considers both IC scalp topographies and activations, uses a probabilistically interpretable threshold for accepting ICs as reliable, and requires applying ICA only three times per data set. As evidence of the method’s validity, we show that the method can perform comparably to more time intensive bootstrap resampling and depends in a reasonable manner on the amount of training data. Finally, using the method we illustrate the importance of checking the reliability of ICs by demonstrating that IC reliability is dramatically increased by removing the mean EEG at each channel for each epoch of data rather than the mean EEG in a prestimulus baseline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 2×
“, 1999) was individually applied to each participant's data from each experiment using the binica function from the EEGLAB Toolbox (Delorme and Makeig, 2004).”
MethodSelf-citationAn Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Advances in neural information processing systems 7
(1996) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(96)90463-0 · Cited by 14,281
The Hungarian method for the assignment problem
Kuhn, H. W. (1955) · Naval Research Logistics Quarterly · doi:10.1002/nav.3800020109 · Cited by 13,120
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 2×
“An infinite number of equally independent decompositions are possible for such data (Bell and Sejnowski, 1995; Meinecke et al., 2002). when computing bias-corrected and accelerated bootstrap confidence intervals.”
BackgroundIndependent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
A blind source separation technique using second-order statistics
Belouchrani, A., Abed-Meraim, K., Cardoso, J.-F., & Moulines, E. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,775 · cited 1×
“In contrast, another ICA algorithm, second-order blind identification (Belouchrani et al., 1997) analytically derives an unmixing matrix such that the dimensions of u are uncorrelated at multiple time lags (here, decorrelation is used as a rough approximation of independence).”
MethodIndependent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationElectric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Cited by
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Mass univariate analysis of event‐related brain potentials/fields I: A critical tutorial review
Groppe, D. M., Urbach, T. P., & Kutas, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01273.x · Cited by 1,169
Self-citationKeil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Rogasch, N. C., Sullivan, C., Thomson, R. H., Rose, N. S., Bailey, N. W., Fitzgerald, P. B., Farzan, F., & Hernandez-Pavon, J. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.031 · Cited by 411
“number of trials) has a substantial impact on ICA reliability (Groppe et al., 2009) (Fig.”
InfluentialOn the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319296 · Cited by 407
Smith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
A review of the use of psychophysiological methods in game research
Kivikangas, J. M., Chanel, G., Cowley, B., Ekman, I., Salminen, M., Järvelä, S., & Ravaja, N. (2011) · Journal of Gaming & Virtual Worlds · doi:10.1386/jgvw.3.3.181_1 · Cited by 288
Klug, M., & Gramann, K. (2021) · European Journal of Neuroscience · doi:10.1111/ejn.14992 · Cited by 268
Optimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments
Dimigen, O. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116117 · Cited by 222
“From each epoch, I then removed the mean channel voltages across the epoch (mean-centering, Groppe et al., 2009).”
InfluentialFATCAT: (An Efficient) Functional And Tractographic Connectivity Analysis Toolbox
Taylor, P. A., & Saad, Z. S. (2013) · Brain Connectivity · doi:10.1089/brain.2013.0154 · Cited by 210
“The IC-defined networks are shown in Figure 3 (left columns of each panel), with the following associations (i.e., all ICs here show significant but not identical overlapping with the FCP networks, due, for example, to different splitting of components; see e.g. Groppe et al. [2009]): (Fig.”
Artoni, F., Delorme, A., & Makeig, S. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.016 · Cited by 198
“, without a spatially fixed 30 distribution or source, such as produced by unconstrained cap movement) (Groppe et al., 2009).”
BackgroundSelf-citationIndependent component analysis of short-time Fourier transforms for spontaneous EEG/MEG analysis
Hyvärinen, A., Ramkumar, P., Parkkonen, L., & Hari, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.028 · Cited by 181
Luo, Y., Chen, L., Li, H., Dong, Y., Zhou, X., Qiu, L., Zhang, L., Gao, Y., Zhu, C., Yu, F., et al. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.585086 · Cited by 11
Metadata
- Authors
- Groppe, D. M., Makeig, S., & Kutas, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 45
- Issue
- 4
- Pages
- 1199-1211
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2113961865
- Cited by
- 207
- References
- 39
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.