The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG
Open accessAbstract
Muscle electrical activity, or “electromyogenic” (EMG) artifact, poses a serious threat to the validity of electroencephalography (EEG) investigations in the frequency domain. EMG is sensitive to a variety of psychological processes and can mask genuine effects or masquerade as legitimate neurogenic effects across the scalp in frequencies at least as low as the alpha band (8–13Hz). Although several techniques for correcting myogenic activity have been described, most are subjected to only limited validation attempts. Attempts to gauge the impact of EMG correction on intracerebral source models (source “localization” analyses) are rarer still. Accordingly, we assessed the sensitivity and specificity of one prominent correction tool, independent component analysis (ICA), on the scalp and in the source-space using high-resolution EEG. Data were collected from 17 participants while neurogenic and myogenic activity was independently varied. Several protocols for classifying and discarding components classified as myogenic and non-myogenic artifact (e.g., ocular) were systematically assessed, leading to the exclusion of one-third to as much as three-quarters of the variance in the EEG. Some, but not all, of these protocols showed adequate performance on the scalp. Indeed, performance was superior to previously validated regression-based techniques. Nevertheless, ICA-based EMG correction exhibited low validity in the intracerebral source-space, likely owing to incomplete separation of neurogenic from myogenic sources. Taken with prior work, this indicates that EMG artifact can substantially distort estimates of intracerebral spectral activity. Neither regression- nor ICA-based EMG correction techniques provide complete safeguards against such distortions. In light of these results, several practical suggestions and recommendations are made for intelligently using ICA to minimize EMG and other common artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Nonparametric permutation tests for functional neuroimaging: A primer with examples
Nichols, T. E., & Holmes, A. P. (2002) · Human Brain Mapping · doi:10.1002/hbm.1058 · Cited by 6,256
(2001) · doi:10.1017/cbo9780511546396 · Cited by 4,482
Answering the Call for a Standard Reliability Measure for Coding Data
Hayes, A. F., & Krippendorff, K. (2007) · Communication Methods and Measures · doi:10.1080/19312450709336664 · Cited by 4,225 · cited 2×
“Interrater reliability, assessed prior to consensus using Krippendorff's alpha (Hayes and Krippendorff, 2007), was excellent, α=0.”
InfluentialAutomatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431 · cited 1×
“The source-space is normalized to the Montreal Neurological Institute's probabilistic MRI anatomical template (i.e., MNI305; Evans et al., 1993; Collins et al., 1994), restricted to the cerebral gray matter, hippocampi, and amygdalae on a 7-mm3 isotropic lattice.”
A method for making group inferences from functional MRI data using independent component analysis
Calhoun, V. D., Adali, T., Pearlson, G. D., & Pekar, J. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1048 · Cited by 2,994
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Emotion and motivation I: Defensive and appetitive reactions in picture processing.
Bradley, M. M., Codispoti, M., Cuthbert, B. N., & Lang, P. J. (2001) · Emotion · doi:10.1037/1528-3542.1.3.276 · Cited by 2,224 · cited 1×
“…numerous cognitive and affective processes, including cognitive load (Cohen et al., 1992; Waterink and van Boxtel, 1994), facial mimicry (Dimberg et al., 2000), vocalization (Brooker and Donald, 1980), and induced emotional states (Borden et al., 1991; Coan and Allen, 2003; Bradley et al., 2001).”
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 3×
“Many validation studies have relied on small samples of ad hoc data (Delorme et al., 2007b; Jung et al., 2000a,b; Wallstrom et al., 2004; Flexer et al., 2005; Ting et al., 2006; Frank and Frishkoff, 2006).”
InfluentialLong-term meditators self-induce high-amplitude gamma synchrony during mental practice
Lutz, A., Greischar, L. L., Rawlings, N. B., Ricard, M., & Davidson, R. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407401101 · Cited by 1,328 · cited 1×
“Thus, while useful for investigations of tonic (“resting”) and induced changes in the EEG spectra (e.g., Lutz et al., 2004), GLM-based tools cannot be applied to studies relying on eventrelated spectral perturbation (ERSP) measures (Onton et al., 2006).”
Self-citationTransient induced gamma-band response in EEG as a manifestation of miniature saccades
Yuval-Greenberg, S., Tomer, O., Keren, A. S., Nelken, I., & Deouell, L. Y. (2008) · Neuron · doi:10.1016/j.neuron.2008.03.027 · Cited by 776
Cognitive therapy versus medication for depression: treatment outcomes and neural mechanisms
DeRubeis, R. J., Siegle, G. J., & Hollon, S. D. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2345 · Cited by 690 · cited 1×
“…perception and attention (Romei et al., 2008; Thut andMiniussi, 2009), emotion (Coan and Allen, 2003; Davidson et al., 1990), temperament and individual differences (Carver and Harmon-Jones, 2009; Shackman et al., in press), and psychopathology (Thibodeau et al., 2006; DeRubeis et al., 2008).”
Whitham, E. M., Pope, K. J., Fitzgibbon, S. P., Lewis, T., Clark, C. R., Loveless, S., Broberg, M., Wallace, A., DeLosAngeles, D., Lillie, P., et al. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.027 · Cited by 524 · cited 1×
“Nevertheless, it would be informative to validate ICA and other EMG correction techniques using data obtained during neuromuscular blockade (Whitham et al., 2007).”
Anxiety selectively disrupts visuospatial working memory
Shackman, A. J., Sarinopoulos, I., Maxwell, J. S., Pizzagalli, D. A., Lavric, A., & Davidson, R. J. (2006) · Emotion · doi:10.1037/1528-3542.6.1.40 · Cited by 382
Self-citationNociceptive Laser-Evoked Brain Potentials Do Not Reflect Nociceptive-Specific Neural Activity
Mouraux, A., & Iannetti, G. D. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91181.2008 · Cited by 373
Right Dorsolateral Prefrontal Cortical Activity and Behavioral Inhibition
Shackman, A. J., McMenamin, B. W., Maxwell, J. S., Greischar, L. L., & Davidson, R. J. (2009) · Psychological Science · doi:10.1111/j.1467-9280.2009.02476.x · Cited by 287
Self-citationFunctional coupling of simultaneous electrical and metabolic activity in the human brain
Oakes, T. R., Pizzagalli, D. A., Hendrick, A. M., Horras, K. A., Larson, C. L., Abercrombie, H. C., Schaefer, S. M., Koger, J. V., & Davidson, R. J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20004 · Cited by 235
Self-citationMilne, E., Scope, A., Pascalis, O., Buckley, D., & Makeig, S. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.07.017 · Cited by 148
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Rogasch, N. C., Sullivan, C., Thomson, R. H., Rose, N. S., Bailey, N. W., Fitzgerald, P. B., Farzan, F., & Hernandez-Pavon, J. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.031 · Cited by 411
Smith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Metadata
- Authors
- McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 49
- Issue
- 3
- Pages
- 2416-2432
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2084461382
- Cited by
- 211
- References
- 19
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.