Optimization of PET–MR registrations for nonhuman primates using mutual information measures: A Multi-Transform Method (MTM)
Open accessThe DOI matches its Crossref record.
Abstract
An important step in PET brain kinetic analysis is the registration of functional data to an anatomical MR image. Typically, PET-MR registrations in nonhuman primate neuroreceptor studies used PET images acquired early post-injection, (e.g., 0–10 min) to closely resemble the subject’s MR image. However, a substantial fraction of these registrations (~25%) fail due to the differences in kinetics and distribution for various radiotracer studies and conditions (e.g., blocking studies). The Multi-Transform Method (MTM) was developed to improve the success of registrations between PET and MR images. Two algorithms were evaluated, MTM-I and MTM-II. The approach involves creating multiple transformations by registering PET images of different time intervals, from a dynamic study, to a single reference (i.e., MR image) (MTM-I) or to multiple reference images (i.e., MR and PET images pre-registered to the MR) (MTM-II). Normalized mutual information was used to compute similarity between the transformed PET images and the reference image(s) to choose the optimal transformation. This final transformation is used to map the dynamic dataset into the animal’s anatomical MR space, required for kinetic analysis. The chosen transformed from MTM-I and MTM-II were evaluated using visual rating scores to assess the quality of spatial alignment between the resliced PET and reference. One hundred twenty PET datasets involving eleven different tracers from 3 different scanners were used to evaluate the MTM algorithms. Studies were performed with baboons and rhesus monkeys on the HR+, HRRT, and Focus-220. Successful transformations increased from 77.5%, 85.8%, to 96.7% using the 0–10 min method, MTM-I, and MTM-II, respectively, based on visual rating scores. The Multi-Transform Methods proved to be a robust technique for PET-MR registrations for a wide range of PET studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 28
- Baare, 2001, Quantitative genetic modeling of variation in human brain morphology, Cereb. Cortex, 11, 816, 10.1093/cercor/11.9.816 · DOI · Paper page
- Black, 2004, Atlas template images for nonhuman primate neuroimaging: baboon and macaque, Methods Enzymol., 385, 91, 10.1016/S0076-6879(04)85006-7 · DOI
- Cheverud, 1990, Heritability of brain size and surface features in rhesus macaques (Macaca mulatta), J. Hered., 81, 51, 10.1093/oxfordjournals.jhered.a110924 · DOI · Paper page
- Collignon, 1995, Automated multi-modality image registration based on information theory, Inf. Process. Med. Imaging, 3, 263
- Cosgrove, 2011, Assessing the sensitivity of [11C]P943, a novel 5-HT(1B) radioligand, to endogenous serotonin release, Synapse, 65, 1113, 10.1002/syn.20942 · DOI
- Davatzikos, 2001, Accuracy and sensitivity of detection of activation foci in the brain via statistical parametric mapping: a study using a PET simulator, Neuroimage, 13, 176, 10.1006/nimg.2000.0655 · DOI
- Gallezot, 2011, Evaluation of [(11)C]MRB for assessment of occupancy of norepinephrine transporters: studies with atomoxetine in non-human primates, Neuroimage, 56, 268, 10.1016/j.neuroimage.2010.09.040 · DOI · Paper page
- Gholipour, 2007, Brain functional localization: a survey of image registration techniques, IEEE Trans. Med. Imaging, 26, 427, 10.1109/TMI.2007.892508 · DOI · Paper page
- Graff-Guerrero, 2008, Brain region binding of the D2/3 agonist [11C]-(+)-PHNO and the D2/3 antagonist [11C]raclopride in healthy humans, Hum. Brain Mapp., 29, 400, 10.1002/hbm.20392 · DOI · Paper page
- Huang, 2004, A new positron emission tomography imaging agent for the serotonin transporter: synthesis, pharmacological characterization, and kinetic analysis of [11C]2-[2-(dimethylaminomethyl)phenylthio]-5-fluoromethylphenylamine ([11C]AFM), Nucl. Med. Biol., 31, 543, 10.1016/j.nucmedbio.2003.11.008 · DOI
- Jenkinson, 2002, Improved optimization for the robust and accurate linear registration and motion correction of brain images, Neuroimage, 17, 825, 10.1006/nimg.2002.1132 · DOI · Paper page
- Kiebel, 1997, MRI and PET coregistration — a cross validation of statistical parametric mapping and automated image registration, Neuroimage, 5, 271, 10.1006/nimg.1997.0265 · DOI
- Lehnert, 2006, Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner, Phys. Med. Biol., 51, 4003, 10.1088/0031-9155/51/16/008 · doi:10.1088/0031-9155/51/16/008
- Maintz, 1998, A survey of medical image registration, Med. Image Anal., 2, 1, 10.1016/S1361-8415(01)80026-8 · DOI · Paper page
- McLaren, 2009, A population-average MRI-based atlas collection of the rhesus macaque, Neuroimage, 45, 52, 10.1016/j.neuroimage.2008.10.058 · DOI · Paper page
- Myers, 2002, The application of PET–MR image registration in the brain, Br. J. Radiol., 75, S31, 10.1259/bjr.75.suppl_9.750031 · DOI
- Nabulsi, 2010, High-resolution imaging of brain 5-HT 1B receptors in the rhesus monkey using [11C]P943, Nucl. Med. Biol., 37, 205, 10.1016/j.nucmedbio.2009.10.007 · DOI · Paper page
- Nabulsi, 2011, [(11)C]GR103545: novel one-pot radiosynthesis with high specific activity, Nucl. Med. Biol., 38, 215, 10.1016/j.nucmedbio.2010.08.014 · DOI
- Skerl, 2006, A protocol for evaluation of similarity measures for rigid registration, IEEE Trans. Med. Imaging, 25, 779, 10.1109/TMI.2006.874963 · DOI · Paper page
- Studholme, 1997, Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures, Med. Phys., 24, 25, 10.1118/1.598130 · DOI · Paper page
- Studholme, 1999, An overlap invariant entropy measure of 3D medical image alignment, Pattern Recognit., 32, 71, 10.1016/S0031-3203(98)00091-0 · DOI · Paper page
- van Velden, 2009, HRRT versus HR+ human brain PET studies: an interscanner test–retest study, J. Nucl. Med., 50, 693, 10.2967/jnumed.108.058628 · DOI
- Wand, 2011, Naloxone-induced cortisol predicts mu opioid receptor binding potential in specific brain regions of healthy subjects, Psychoneuroendocrinology, 36, 1453, 10.1016/j.psyneuen.2011.03.019 · DOI
- Wang, 2007, Synthesis and preliminary biological evaluation of 3-[(18)F]fluoro-5-(2-pyridinylethynyl)benzonitrile as a PET radiotracer for imaging metabotropic glutamate receptor subtype 5, Synapse, 61, 951, 10.1002/syn.20445 · DOI
- Wilson, 2008, Radiosynthesis and initial evaluation of [18F]-FEPPA for PET imaging of peripheral benzodiazepine receptors, Nucl. Med. Biol., 35, 305, 10.1016/j.nucmedbio.2007.12.009 · DOI · Paper page
- Wong, 2010, Quantification of cerebral cannabinoid receptors subtype 1 (CB1) in healthy subjects and schizophrenia by the novel PET radioligand [11C]OMAR, Neuroimage, 52, 1505, 10.1016/j.neuroimage.2010.04.034 · DOI · Paper page
- Woods, 1993, MRI–PET registration with automated algorithm, J. Comput. Assist. Tomogr., 17, 536, 10.1097/00004728-199307000-00004 · DOI · Paper page
- Zamuner, 2012, A pharmacokinetic PET study of NK receptor occupancy, Eur. J. Nucl. Med. Mol. Imaging, 39, 226, 10.1007/s00259-011-1954-2 · DOI
Cited by
Imaging synaptic density in the living human brain
Finnema, S. J., Nabulsi, N. B., Eid, T., Detyniecki, K., Lin, S.-F., Chen, M.-K., Dhaher, R., Matuskey, D., Baum, E., Holden, D., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6667 · Cited by 575
Self-citationNabulsi, N. B., Mercier, J., Holden, D., Carré, S., Najafzadeh, S., Vandergeten, M.-C., Lin, S.-F., Deo, A., Price, N., Wood, M., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.168179 · Cited by 296
“Registration parameters were obtained to apply the regions of interest to individual PET scans (21), and regional time–activity curves were generated.”
MethodSelf-citationImaging the effect of ketamine on synaptic density (SV2A) in the living brain
Holmes, S. E., Finnema, S. J., Naganawa, M., DellaGioia, N., Holden, D., Fowles, K., Davis, M., Ropchan, J., Emory, P., Ye, Y., et al. (2022) · Molecular Psychiatry · doi:10.1038/s41380-022-01465-2 · Cited by 78
“Registration parameters were used to apply the ROIs to individual PET scans, as described previously [52].”
MethodSelf-citationLi, S., Cai, Z., Zhang, W., Holden, D., Lin, S.-F., Finnema, S. J., Shirali, A., Ropchan, J., Carre, S., Mercier, J., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04357-w · Cited by 59
Self-citation
Metadata
- Authors
- Sandiego, C. M., Weinzimmer, D., & Carson, R. E.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 64
- Pages
- 571-581
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2105888777
- Cited by
- 30
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- National Center for Advancing Translational Sciences
- National Institutes of Health
- National Center for Research Resources
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.