The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series
Open accessAbstract
The impact of in-scanner head movement on functional magnetic resonance imaging (fMRI) signals has long been established as undesirable. These effects have been traditionally corrected by methods such as linear regression of head movement parameters. However, a number of recent independent studies have demonstrated that these techniques are insufficient to remove motion confounds, and that even small movements can spuriously bias estimates of functional connectivity. Here we propose a new data-driven, spatially-adaptive, wavelet-based method for identifying, modeling, and removing non-stationary events in fMRI time series, caused by head movement, without the need for data scrubbing. This method involves the addition of just one extra step, the Wavelet Despike, in standard pre-processing pipelines. With this method, we demonstrate robust removal of a range of different motion artifacts and motion-related biases including distance-dependent connectivity artifacts, at a group and single-subject level, using a range of previously published and new diagnostic measures. The Wavelet Despike is able to accommodate the substantial spatial and temporal heterogeneity of motion artifacts and can consequently remove a range of high and low frequency artifacts from fMRI time series, that may be linearly or non-linearly related to physical movements. Our methods are demonstrated by the analysis of three cohorts of resting-state fMRI data, including two high-motion datasets: a previously published dataset on children (N=22) and a new dataset on adults with stimulant drug dependence (N=40). We conclude that there is a real risk of motion-related bias in connectivity analysis of fMRI data, but that this risk is generally manageable, by effective time series denoising strategies designed to attenuate synchronized signal transients induced by abrupt head movements. The Wavelet Despiking software described in this article is freely available for download at www.brainwavelet.org.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Functional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Power, J. D., Barnes, K. A., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.018 · Cited by 7,429
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Wavelet methods for time series analysis
(2001) · Choice Reviews Online · doi:10.5860/choice.38-4508 · Cited by 2,574
The influence of head motion on intrinsic functional connectivity MRI
Van Dijk, K. R. A., Sabuncu, M. R., & Buckner, R. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.044 · Cited by 2,344
Satterthwaite, T. D., Elliott, M. A., Gerraty, R. T., Ruparel, K., Loughead, J., Calkins, M. E., Eickhoff, S. B., Hakonarson, H., Gur, R. C., Gur, R. E., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.052 · Cited by 1,881
Yan, C.-G., Cheung, B., Kelly, C., Colcombe, S., Craddock, R. C., Di Martino, A., Li, Q., Zuo, X.-N., Castellanos, F. X., & Milham, M. P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.004 · Cited by 1,461
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Whole-brain anatomical networks: does the choice of nodes matter?
Zalesky, A., Fornito, A., Harding, I. H., Cocchi, L., Yücel, M., Pantelis, C., & Bullmore, E. T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.027 · Cited by 1,169
Self-citationSatterthwaite, T. D., Wolf, D. H., Loughead, J., Ruparel, K., Elliott, M. A., Hakonarson, H., Gur, R. C., & Gur, R. E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.063 · Cited by 1,125
Bullmore, E. T., Suckling, J., Overmeyer, S., Rabe-Hesketh, S., Taylor, E., & Brammer, M. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.750253 · Cited by 1,088
Self-citationLongitudinal Analysis of Neural Network Development in Preterm Infants
Smyser, C. D., Inder, T. E., Shimony, J. S., Hill, J. E., Degnan, A. J., Snyder, A. Z., & Neil, J. J. (2010) · Cerebral Cortex · doi:10.1093/cercor/bhq035 · Cited by 791
Weissenbacher, A., Kasess, C., Gerstl, F., Lanzenberger, R., Moser, E., & Windischberger, C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.005 · Cited by 776
Tensorial extensions of independent component analysis for multisubject FMRI analysis
Beckmann, C. F., & Smith, S. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.043 · Cited by 761
Statistical methods of estimation and inference for functional MR image analysis
Bullmore, E., Brammer, M., Williams, S. C. R., Rabe‐Hesketh, S., Janot, N., David, A., Mellers, J., Howard, R., & Sham, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350219 · Cited by 683
Self-citationDifferentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S. J., Evans, J. W., Luh, W.-M., & Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 615
Self-citationArtifacts due to stimulus correlated motion in functional imaging of the brain
Hajnal, J. V., Myers, R., Oatridge, A., Schwieso, J. E., Young, I. R., & Bydder, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310307 · Cited by 486
Bullmore, E. T., Brammer, M. J., Rabe-Hesketh, S., Curtis, V. A., Morris, R. G., Williams, S. C. R., Sharma, T., & McGuire, P. K. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:1<38::aid-hbm4>3.0.co;2-q · Cited by 455
Self-citationPoser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
Steps toward optimizing motion artifact removal in functional connectivity MRI; a reply to Carp
Power, J. D., Barnes, K. A., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.017 · Cited by 335
Motion correction and the use of motion covariates in multiple‐subject fMRI analysis
Johnstone, T., Ores Walsh, K. S., Greischar, L. L., Alexander, A. L., Fox, A. S., Davidson, R. J., & Oakes, T. R. (2006) · Human Brain Mapping · doi:10.1002/hbm.20219 · Cited by 320
Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI
Chang, C., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.048 · Cited by 292
Jo, H. J., Gotts, S. J., Reynolds, R. C., Bandettini, P. A., Martin, A., Cox, R. W., & Saad, Z. S. (2013) · Journal of Applied Mathematics · doi:10.1155/2013/935154 · Cited by 276
Bianciardi, M., Fukunaga, M., van Gelderen, P., Horovitz, S. G., de Zwart, J. A., Shmueli, K., & Duyn, J. H. (2009) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.02.004 · Cited by 239
Tyszka, J. M., Kennedy, D. P., Paul, L. K., & Adolphs, R. (2014) · Cerebral Cortex · doi:10.1093/cercor/bht040 · Cited by 187
Optimizing the order of operations for movement scrubbing: Comment on Power et al.
Carp, J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.061 · Cited by 172
Mowinckel, A. M., Espeseth, T., & Westlye, L. T. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.004 · Cited by 153
Fractal connectivity of long-memory networks
Achard, S., Bassett, D. S., Meyer‐Lindenberg, A., & Bullmore, E. T. (2008) · Physical Review E · doi:10.1103/physreve.77.036104 · Cited by 147
Self-citationAn alternative approach towards assessing and accounting for individual motion in fMRI timeseries
Wilke, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.043 · Cited by 125
Removing motion and physiological artifacts from intrinsic BOLD fluctuations using short echo data
Bright, M. G., & Murphy, K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.043 · Cited by 89
Cited by
GRETNA: a graph theoretical network analysis toolbox for imaging connectomics
Wang, J., Wang, X., Xia, M., Liao, X., Evans, A., & He, Y. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00386 · Cited by 1,422
Ciric, R., Wolf, D. H., Power, J. D., Roalf, D. R., Baum, G. L., Ruparel, K., Shinohara, R. T., Elliott, M. A., Eickhoff, S. B., Davatzikos, C., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.020 · Cited by 1,042
Recent progress and outstanding issues in motion correction in resting state fMRI
Power, J. D., Schlaggar, B. L., & Petersen, S. E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.044 · Cited by 957
Parkes, L., Fulcher, B., Yücel, M., & Fornito, A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.073 · Cited by 801
Taylor, J. R., Williams, N., Cusack, R., Auer, T., Shafto, M. A., Dixon, M., Tyler, L. K., Cam-CAN, & Henson, R. N. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.018 · Cited by 782
Metadata
- Authors
- Patel, A. X., Kundu, P., Rubinov, M., Jones, P. S., Vértes, P. E., Ersche, K. D., Suckling, J., & Bullmore, E. T.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 95
- Pages
- 287-304
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2050597556
- Cited by
- 363
- References
- 33
- FWCI
- 16.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.