Resolution and b value dependent structural connectome in ex vivo mouse brain
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Abstract Diffusion magnetic resonance imaging has been widely used in both clinical and preclinical studies to characterize tissue microstructure and structural connectivity. The diffusion MRI protocol for the Human Connectome Project (HCP) has been developed and optimized to obtain high-quality, high-resolution diffusion MRI (dMRI) datasets. However, such efforts have not been fully explored in preclinical studies, especially for rodents. In this study, high quality dMRI datasets of mouse brains were acquired at 9.4T system from two vendors. In particular, we acquired a high-spatial resolution dMRI dataset (25 μm isotropic with 126 diffusion encoding directions), which we believe to be the highest spatial resolution yet obtained; and a high-angular resolution dMRI dataset (50 μm isotropic with 384 diffusion encoding directions), which we believe to be the highest angular resolution compared to the dMRI datasets at the microscopic resolution. We systematically investigated the effects of three important parameters that affect the final outcome of the connectome: b value (1000 s/mm 2 to 8000 s/mm 2 ), angular resolution (10 to 126), and spatial resolution (25 µm to 200 µm). The stability of tractography and connectome increase with the angular resolution, where more than 50 angles are necessary to achieve consistent results. The connectome and quantitative parameters derived from graph theory exhibit a linear relationship to the b value (R 2 > 0.99); a single-shell acquisition with b value of 3000 s/mm 2 shows comparable results to the multi-shell high angular resolution dataset. The dice coefficient decreases and both false positive rate and false negative rate gradually increase with coarser spatial resolution. Our study provides guidelines and foundations for exploration of tradeoffs among acquisition parameters for the structural connectome in ex vivo mouse brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation
Tournier, J.-D., Smith, R., Raffelt, D., Tabbara, R., Dhollander, T., Pietsch, M., Christiaens, D., Jeurissen, B., Yeh, C.-H., & Connelly, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116137 · Cited by 2,974
A mesoscale connectome of the mouse brain
Oh, S. W., Harris, J. A., Ng, L., Winslow, B., Cain, N., Mihalas, S., Wang, Q., Lau, C., Kuan, L., Henry, A. M., et al. (2014) · Nature · doi:10.1038/nature13186 · Cited by 2,612
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 1×
“The HCP scanner can achieve b values up to 20,550 s/mm2 with maximum gradients of 300 mT/m to generate structural connectome and probe the different tissue microstructures in live humans (Duval et al., 2015; Guglielmetti et al., 2016; Jensen et al., 2005; Landman et al., 2007; Palombo et al., 2020; Zhang et al., 2012).”
BackgroundThe human brain in numbers: a linearly scaled-up primate brain
Herculano-Houzel, S. (2009) · Frontiers in Human Neuroscience · doi:10.3389/neuro.09.031.2009 · Cited by 1,778 · cited 3×
“The adult human brain contains about 86 billion neurons, containing ∼ 62,732 neurons in 1 mm3 (Herculano-Houzel, 2009; Insel et al., 2013).”
BackgroundTournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635 · cited 1×
“A number of model-based and model-free methods have been developed to estimate the orientations of multiple axon populations per voxel, requiring a large number of diffusion-weighted images (DWIs) at the same b value (single-shell), or different b values (multi-shell) (Anderson, 2005; Assaf et al., 2008; Behrens et al…”
MethodHigh angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 2×
“This acquisition method, termed as High Angular Resolution Diffusion Imaging (HARDI), has opened up new potentials to noninvasively measure microstructural features and study white matter connectivity (Berman et al., 2013; Descoteaux and Deriche, 2009; Frank, 2001; Le Bihan et al., 2006; Thomas et al., 2014; Tuch et a…”
BackgroundMethodTractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Deterministic diffusion fiber tracking improved by quantitative anisotropy
Yeh, F.-C., Verstynen, T. D., Wang, Y., Fernández-Miranda, J. C., & Tseng, W.-Y. I. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080713 · Cited by 1,121 · cited 2×
“Tract density imaging (TDI) was also used to facilitate visualization of the whole brain microstructures after tractography is generated (Calamante et al., 2012; Yeh et al., 2013).”
MethodDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Scaling Brain Size, Keeping Timing: Evolutionary Preservation of Brain Rhythms
Buzsáki, G., Logothetis, N., & Singer, W. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.002 · Cited by 886 · cited 1×
“The high spatial resolution dMRI in clinical scan can achieve 1mm3 or even submillimeter resolution, each imaging voxel still has thousands of neurons, which is too large to enable the resolution of axons (Buzsaki et al., 2013).”
BackgroundAxcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 2×
“Various biophysical models have been developed to probe the tissue microstructure, but the b values may vary dramatically for different models (Alexander et al., 2002; Assaf et al., 2008; Calamante et al., 2010; Edwards et al., 2017; Henriques et al., 2019; Huang et al., 2020; Kaden et al., 2016; Tournier et al., 2004…”
BackgroundMethodThomas, C., Ye, F. Q., Irfanoglu, M. O., Modi, P., Saleem, K. S., Leopold, D. A., & Pierpaoli, C. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405672111 · Cited by 725 · cited 1×
“This acquisition method, termed as High Angular Resolution Diffusion Imaging (HARDI), has opened up new potentials to noninvasively measure microstructural features and study white matter connectivity (Berman et al., 2013; Descoteaux and Deriche, 2009; Frank, 2001; Le Bihan et al., 2006; Thomas et al., 2014; Tuch et a…”
MethodOrientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683 · cited 1×
“Diffusion magnetic resonance imaging (dMRI) is an important and unique technique to study brain microstructure and connections due to its sensitivity to random thermal motions of water (Alexander et al., 2010; Basser et al., 1994; Basser et al., 2000; Vu et al., 2015; Zhang et al., 2012).”
BackgroundInvestigating white matter fibre density and morphology using fixel-based analysis.
Raffelt, D. A., Tournier, J.-D., Smith, R. E., Vaughan, D. N., Jackson, G., Ridgway, G. R., & Connelly, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.029 · Cited by 620 · cited 1×
“Recently, a quantitative comparison of the FODs has been proposed to provide more anatomically specific information about the microstructural properties of white matter populations, which is guaranteed in future studies (Raffelt et al., 2017; Tournier et al., 2019; Wu et al., 2020).”
BackgroundPushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Tournier, J. ‐., Calamante, F., & Connelly, A. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3017 · Cited by 403 · cited 4×
“It is recommended to acquire more than the minimum of 45 DW directions to avoid issues with imperfections in the uniformity of the DW gradient directions and to meet SNR requirements of the intended reconstruction method (Tournier et al., 2013).”
BackgroundMethodInfluentialAnisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
SANDI: a compartment‐based model for non‐invasive apparent soma and neurite imaging by diffusion MRI
Palombo, M., Ianus, A., Guerreri, M., Nunes, D., Alexander, D. C., Shemesh, N., & Zhang, H. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116835 · Cited by 349 · cited 2×
“Considering the relatively small variation of the axon diameter between mouse and human brains, the improvement of spatial resolution in rodent MRI may dramatically reduce the partial volume effect and could be used to develop new tractography algorithms and validate novel diffusion biophysical models (Henriques et al…”
BackgroundMulti-compartment microscopic diffusion imaging
Kaden, E., Kelm, N. D., Carson, R. P., Does, M. D., & Alexander, D. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.002 · Cited by 345 · cited 1×
“Various biophysical models have been developed to probe the tissue microstructure, but the b values may vary dramatically for different models (Alexander et al., 2002; Assaf et al., 2008; Calamante et al., 2010; Edwards et al., 2017; Henriques et al., 2019; Huang et al., 2020; Kaden et al., 2016; Tournier et al., 2004…”
BackgroundLiewald, D., Miller, R., Logothetis, N., Wagner, H.-J., & Schüz, A. (2014) · Biological Cybernetics · doi:10.1007/s00422-014-0626-2 · Cited by 322 · cited 2×
“Compared to the brain volume and spatial resolution differences, the axon diameter difference between rodent brain and human brain is much smaller (Barazany et al., 2009; Lee et al., 2019; Liewald et al., 2014).”
BackgroundBuilding connectomes using diffusion MRI: why, how and but
Sotiropoulos, S. N., & Zalesky, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3752 · Cited by 290 · cited 1×
“The effect of b value on tractogram has been investigated in previous studies, but remains largely unanswered for preclinical MRI (Anderson et al., 2020; Schilling et al., 2017b; Sepehrband et al., 2017; Sotiropoulos and Zalesky, 2017).”
BackgroundGaryfallidis, E., Côté, M.-A., Rheault, F., Sidhu, J., Hau, J., Petit, L., Fortin, D., Cunanne, S., & Descoteaux, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.015 · Cited by 279 · cited 1×
“A more thorough comparison among different tractography algorithms and different software should be investigated in detail (Christiaens et al., 2015; Garyfallidis et al., 2018; Sarwar et al., 2019; Woolrich et al., 2009).”
BackgroundA diffusion MRI tractography connectome of the mouse brain and comparison with neuronal tracer data
Calabrese, E., Badea, A., Cofer, G., Qi, Y., & Johnson, G. A. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhv121 · Cited by 221 · cited 5×
“The diffusion MRI images at 25 μm isotropic resolution with 126 DWIs were registered to the AMBA using advanced normalization tools (ANTs) automated image registration, which has been described in previous study in detail (Avants et al., 2011; Calabrese et al., 2015).”
BackgroundMethodResultInfluentialSelf-citationColgan, N., Siow, B., O'Callaghan, J. M., Harrison, I. F., Wells, J. A., Holmes, H. E., Ismail, O., Richardson, S., Alexander, D. C., Collins, E. C., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.043 · Cited by 218 · cited 1×
“The high spatial resolution in preclinical MRI may help to study the layer-specific cytoarchitecture variations of the cerebral cortex in different neurodegenerative diseases, which is still challenging in clinical studies due to the coarse resolution and partial volume effect (Assaf, 2019; Colgan et al., 2016; Vu et…”
BackgroundJelescu, I. O., Veraart, J., Adisetiyo, V., Milla, S. S., Novikov, D. S., & Fieremans, E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.009 · Cited by 202
Histological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
Global tractography of multi-shell diffusion-weighted imaging data using a multi-tissue model
Christiaens, D., Reisert, M., Dhollander, T., Sunaert, S., Suetens, P., & Maes, F. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.008 · Cited by 152 · cited 1×
“A more thorough comparison among different tractography algorithms and different software should be investigated in detail (Christiaens et al., 2015; Garyfallidis et al., 2018; Sarwar et al., 2019; Woolrich et al., 2009).”
BackgroundImaging laminar structures in the gray matter with diffusion MRI
Assaf, Y. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.096 · Cited by 108 · cited 4×
“…cytoarchitecture variations of the cerebral cortex in different neurodegenerative diseases, which is still challenging in clinical studies due to the coarse resolution and partial volume effect (Assaf, 2019; Colgan et al., 2016; Vu et al., 2015; Wang et al., 2020; Wu and Zhang, 2016).”
BackgroundInfluentialCan increased spatial resolution solve the crossing fiber problem for diffusion MRI?
Schilling, K., Gao, Y., Janve, V., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3787 · Cited by 102
Neurite orientation dispersion and density imaging of mouse brain microstructure
Wang, N., Zhang, J., Cofer, G., Qi, Y., Anderson, R. J., White, L. E., & Allan Johnson, G. (2019) · Brain Structure and Function · doi:10.1007/s00429-019-01877-x · Cited by 75 · cited 2×
“For Varian scanner, one mouse was scanned at 25 μm isotropic resolution with b value of 3000 s/mm2; one mouse was scanned with 8 shells at 50 μM isotropic resolution (Wang et al., 2019); Five mice were scanned with 2 shells at 50 um isotropic resolution.”
MethodSelf-citationHutchinson, E. B., Avram, A. V., Irfanoglu, M. O., Koay, C. G., Barnett, A. S., Komlosh, M. E., Özarslan, E., Schwerin, S. C., Juliano, S. L., & Pierpaoli, C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26575 · Cited by 73 · cited 2×
“an imaging voxel, and fit different biophysical models (Ferizi et al., 2017; Hutchinson et al., 2017).”
MethodAydogan, D. B., Jacobs, R., Dulawa, S., Thompson, S. L., Francois, M. C., Toga, A. W., Dong, H., Knowles, J. A., & Shi, Y. (2018) · Brain Structure and Function · doi:10.1007/s00429-018-1663-8 · Cited by 72 · cited 6×
“, 2020); and a high-angular resolution dMRI dataset (50 μm isotropic with 384 DWIs), which we believe to be the highest angular resolution compared to the dMRI datasets at the microscopic resolution (Alomair et al., 2015; Aydogan et al., 2018; Johnson et al., 2019; Wu et al., 2013; Wu and Zhang, 2016; Yon et al., 2020…”
BackgroundMethodResultInfluentialWhole mouse brain structural connectomics using magnetic resonance histology
Wang, N., Anderson, R. J., Badea, A., Cofer, G., Dibb, R., Qi, Y., & Johnson, G. A. (2018) · Brain Structure and Function · doi:10.1007/s00429-018-1750-x · Cited by 71
Self-citationCytoarchitecture of the mouse brain by high resolution diffusion magnetic resonance imaging
Wang, N., White, L. E., Qi, Y., Cofer, G., & Johnson, G. A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116876 · Cited by 47
Self-citation
Cited by
Merged magnetic resonance and light sheet microscopy of the whole mouse brain
Johnson, G. A., Tian, Y., Ashbrook, D. G., Cofer, G. P., Cook, J. J., Gee, J. C., Hall, A., Hornburg, K., Kaczorowski, C. C., Qi, Y., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2218617120 · Cited by 64
Self-citationTowards reliable reconstruction of the mouse brain corticothalamic connectivity using diffusion MRI
Arefin, T. M., Lee, C. H., Liang, Z., Rallapalli, H., Wadghiri, Y. Z., Turnbull, D. H., & Zhang, J. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120111 · Cited by 17
Age-dependent microstructure alterations in 5xFAD mice by high-resolution diffusion tensor imaging
Maharjan, S., Tsai, A. P., Lin, P. B., Ingraham, C., Jewett, M. R., Landreth, G. E., Oblak, A. L., & Wang, N. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.964654 · Cited by 15
“3 ms, TR = 100 ms, 61 unique diffusion directions with b-value of 3000 s/mm2 and six non-diffusionweighted (b0) measurements (Crater et al., 2022).”
BackgroundSelf-citationHan, X., Hu, R., Ping, X., Chen, J., Liu, J., Liu, Z., Jin, X., Gao, X., Lin, M., Zhao, Y., et al. (2026) · Alzheimer's & Dementia · doi:10.1002/alz.71908
Self-citation
Metadata
- Authors
- Crater, S., Maharjan, S., Qi, Y., Zhao, Q., Cofer, G., Cook, J. C., Johnson, G. A., & Wang, N.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2022-07
- Volume
- 255
- Pages
- 119199
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W4225291096
- Cited by
- 30
- References
- 35
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.