Accurate white matter lesion segmentation by k nearest neighbor classification with tissue type priors (kNN-TTPs)
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The segmentation and volumetric quantification of white matter (WM) lesions play an important role in monitoring and studying neurological diseases such as multiple sclerosis (MS) or cerebrovascular disease. This is often interactively done using 2D magnetic resonance images. Recent developments in acquisition techniques allow for 3D imaging with much thinner sections, but the large number of images per subject makes manual lesion outlining infeasible. This warrants the need for a reliable automated approach. Here we aimed to improve k nearest neighbor (kNN) classification of WM lesions by optimizing intensity normalization and using spatial tissue type priors (TTPs). METHODS: The kNN-TTP method used kNN classification with 3.0 T 3DFLAIR and 3DT1 intensities as well as MNI-normalized spatial coordinates as features. Additionally, TTPs were computed by nonlinear registration of data from healthy controls. Intensity features were normalized using variance scaling, robust range normalization or histogram matching. The algorithm was then trained and evaluated using a leave-one-out experiment among 20 patients with MS against a reference segmentation that was created completely manually. The performance of each normalization method was evaluated both with and without TTPs in the feature set. Volumetric agreement was evaluated using intra-class coefficient (ICC), and voxelwise spatial agreement was evaluated using Dice similarity index (SI). Finally, the robustness of the method across different scanners and patient populations was evaluated using an independent sample of elderly subjects with hypertension. RESULTS: The intensity normalization method had a large influence on the segmentation performance, with average SI values ranging from 0.66 to 0.72 when no TTPs were used. Independent of the normalization method, the inclusion of TTPs as features increased performance particularly by reducing the lesion detection error. Best performance was achieved using variance scaled intensity features and including TTPs in the feature set: this yielded ICC = 0.93 and average SI = 0.75 ± 0.08. Validation of the method in an independent sample of elderly subjects with hypertension, yielded even higher ICC = 0.96 and SI = 0.84 ± 0.14. CONCLUSION: Adding TTPs increases the performance of kNN based MS lesion segmentation methods. Best performance was achieved using variance scaling for intensity normalization and including TTPs in the feature set, showing excellent agreement with the reference segmentations across a wide range of lesion severity, irrespective of the scanner used or the pathological substrate of the lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)
Kurtzke, J. F. (1983) · Neurology · doi:10.1212/wnl.33.11.1444 · Cited by 15,011 · cited 2×
“The median EDSS score was 4, ranging between 2.5 and 8.0.”
InfluentialMeasures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874 · cited 2×
“Spatial correspondence at voxel level was evaluated using Dice's similarity index (SI) (Dice, 1945) and sensitivity, respectively de fi ned as SI=2×TP/(2 ∗ TP+FP+FN), and sensitivity= TP/(TP+FN),whereTPisthenumberoftruepositives,FPisthenumber of false positives, TN is the number of true negatives…”
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802 · cited 1×
“Magnetic resonance imaging (MRI) plays a key role in diagnosing, monitoring and studying these diseases (Polman et al., 2011; Provenzano et al., 2013).”
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982 · cited 2×
“For the 3DT1 images of the 16 healthy control subjects, voxelwise “ hard ” segmentations of CSF, GM and WM were generated using FSL-FAST (Zhang et al., 2001).”
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872 · cited 1×
“Before constructing the reference segmentation, the 3DT1 image of each subject was rigidly registered to its respective 3DFLAIR image using FLIRT which is part of the FMRIB Software Library (FSL 5.0.2) (Jenkinson and Smith, 2001).”
InfluentialMR signal abnormalities at 1.5 T in Alzheimer's dementia and normal aging
Fazekas, F., Chawluk, J., Alavi, A., Hurtig, H., & Zimmerman, R. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.2.351 · Cited by 5,334 · cited 2×
“…matter lesions (WMLs) is traditionally performed by visual rating or manual outlining on 2D proton density (PD) weighted, T2-weighted, or fl uid attenuated inversion recovery (FLAIR) images with slice thicknesses of 3mm or more (Fazekas et al., 1987; Olsson et al., 2013; Schoonheim et al., 2012).”
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 4×
“Finally, radio frequency (RF) field inhomogeneity correction was performed on both images using the N3 algorithm (Sled, 1997).”
InfluentialElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 2×
“…to the 3DT1 image of the subject of interest using Elastix, which involved an af fi ne and B-spline transformation, both using mutual information as cost-function, gradient descent optimizers, a four-stage pyramidal approach and a fi nal control point resolution of 2.5mm (Klein et al., 2010).”
A Randomized, Placebo-Controlled Trial of Natalizumab for Relapsing Multiple Sclerosis
Polman, C. H., O'Connor, P. W., Havrdova, E., Hutchinson, M., Kappos, L., Miller, D. H., Phillips, J. T., Lublin, F. D., Giovannoni, G., Wajgt, A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa044397 · Cited by 3,386
Cited by
Griffanti, L., Zamboni, G., Khan, A., Li, L., Bonifacio, G., Sundaresan, V., Schulz, U. G., Kuker, W., Battaglini, M., Rothwell, P. M., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.07.018 · Cited by 414
Valverde, S., Cabezas, M., Roura, E., González-Villà, S., Pareto, D., Vilanova, J. C., Ramió-Torrentà, L., Rovira, À., Oliver, A., & Lladó, X. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.034 · Cited by 392
A review on brain tumor segmentation of MRI images
Wadhwa, A., Bhardwaj, A., & Singh Verma, V. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.05.043 · Cited by 374
Cortical atrophy patterns in multiple sclerosis are non-random and clinically relevant
Steenwijk, M. D., Geurts, J. J. G., Daams, M., Tijms, B. M., Wink, A. M., Balk, L. J., Tewarie, P. K., Uitdehaag, B. M. J., Barkhof, F., Vrenken, H., et al. (2016) · Brain · doi:10.1093/brain/awv337 · Cited by 281
Self-citationAutomatic segmentation and volumetry of multiple sclerosis brain lesions from MR images
Jain, S., Sima, D. M., Ribbens, A., Cambron, M., Maertens, A., Van Hecke, W., De Mey, J., Barkhof, F., Steenwijk, M. D., Daams, M., et al. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.05.003 · Cited by 220
Self-citationWeaver, N. A., Doeven, T., Barkhof, F., Biesbroek, J. M., Groeneveld, O. N., Kuijf, H. J., Prins, N. D., Scheltens, P., Teunissen, C. E., van der Flier, W. M., et al. (2019) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2019.08.001 · Cited by 71
Cortical Microinfarcts Detected In Vivo on 3 Tesla MRI: Clinical and Radiological Correlates
van Dalen, J. W., Scuric, E. E. M., van Veluw, S. J., Caan, M. W. A., Nederveen, A. J., Biessels, G. J., van Gool, W. A., & Richard, E. (2015) · Stroke · doi:10.1161/strokeaha.114.007568 · Cited by 73
“White matter hyperintensities (WMHs) were segmented automatically.(5) Total brain and intracranial volumes were obtained using SPM 8 (Wellcome Trust Center for Neuroimaging, University College London, United Kingdom) in Matlab 7.”
MethodSelf-citationvan Dalen, J. W., Moll van Charante, E. P., Caan, M. W. A., Scheltens, P., Majoie, C. B. L. M., Nederveen, A. J., van Gool, W. A., & Richard, E. (2017) · Stroke · doi:10.1161/strokeaha.117.017207 · Cited by 41
“WMH were automatically segmented from fluid-attenuated inversion recovery scans using a k-nearest neighbor algorithm with tissuetype priors, described and validated previously.(17) Total brain volume (TBV) was calculated by adding gray and white matter volumes.”
MethodSelf-citationDetection of white matter lesion regions in MRI using SLIC0 and convolutional neural network
Diniz, P. H. B., Valente, T. L. A., Diniz, J. O. B., Silva, A. C., Gattass, M., Ventura, N., Muniz, B. C., & Gasparetto, E. L. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.011 · Cited by 34
Metadata
- Authors
- Steenwijk, M. D., Pouwels, P. J. W., Daams, M., van Dalen, J. W., Caan, M. W. A., Richard, E., Barkhof, F., & Vrenken, H.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 3
- Pages
- 462-469
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2063948766
- Cited by
- 214
- References
- 39
- FWCI
- 17.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.