Diagnostic value of structural and diffusion imaging measures in schizophrenia
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Objectives: Many studies have attempted to discriminate patients with schizophrenia from healthy controls by machine learning using structural or functional MRI. We included both structural and diffusion MRI (dMRI) and performed random forest (RF) and support vector machine (SVM) in this study. Methods: We evaluated the performance of classifying schizophrenia using RF method and SVM with 504 features (volume and/or fractional anisotropy and trace) from 184 brain regions. We enrolled 47 patients and 23 age- and sex-matched healthy controls and resampled our data into a balanced dataset using a Synthetic Minority Oversampling Technique method. We randomly permuted the classification of all participants as a patient or healthy control 100 times and ran the RF and SVM with leave one out cross validation for each permutation. We then compared the sensitivity and specificity of the original dataset and the permuted dataset. Results: Classification using RF with 504 features showed a significantly higher rate of performance compared to classification by chance: sensitivity (87.6% vs. 47.0%) and specificity (95.9 vs. 48.4%) performed by RF, sensitivity (89.5% vs. 48.0%) and specificity (94.5% vs. 47.1%) performed by SVM. Conclusions: Machine learning using RF and SVM with both volume and diffusion measures can discriminate patients with schizophrenia with a high degree of performance. Further replications are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796 · cited 1×
“This was followed by non-linear registration of T1 images with a b= 0 baseline images of dMRI by Advanced Neuroimaging Tools (Avants et al., 2010; Avants et al., 2011).”
MethodThe basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Strimbu, K., & Tavel, J. A. (2010) · Current Opinion in HIV and AIDS · doi:10.1097/coh.0b013e32833ed177 · Cited by 2,062
Decreased Dendritic Spine Density on Prefrontal Cortical Pyramidal Neurons in Schizophrenia
Glantz, L. A., & Lewis, D. A. (2000) · Archives of General Psychiatry · doi:10.1001/archpsyc.57.1.65 · Cited by 1,636
Diffusion tensor imaging (DTI)-based white matter mapping in brain research: a review
Assaf, Y., & Pasternak, O. (2008) · Journal of Molecular Neuroscience · doi:10.1007/s12031-007-0029-0 · Cited by 1,537 · cited 2×
“DMRI is a method that is very sensitive to microstructural abnormalities (Beaulieu, 2002; Kanaan et al., 2005) including demyelination, axonal loss, edema, and inflammation (Assaf and Pasternak, 2008).”
BackgroundMethodOrrù, G., Pettersson-Yeo, W., Marquand, A. F., Sartori, G., & Mechelli, A. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.01.004 · Cited by 1,012
Single subject prediction of brain disorders in neuroimaging: Promises and pitfalls
Arbabshirani, M. R., Plis, S., Sui, J., & Calhoun, V. D. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.079 · Cited by 912 · cited 6×
“, 2012) although a recent review paper has raised a concern about the issue of generalizability of studies with small sample size reported high performance (Arbabshirani et al., 2017).”
BackgroundResultInfluentialA review of diffusion tensor imaging studies in schizophrenia
Kubicki, M., McCarley, R., Westin, C.-F., Park, H.-J., Maier, S., Kikinis, R., Jolesz, F. A., & Shenton, M. E. (2007) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2005.05.005 · Cited by 769
Self-citationThe optimal template effect in hippocampus studies of diseased populations
Avants, B. B., Yushkevich, P., Pluta, J., Minkoff, D., Korczykowski, M., Detre, J., & Gee, J. C. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.062 · Cited by 640 · cited 1×
“This was followed by non-linear registration of T1 images with a b= 0 baseline images of dMRI by Advanced Neuroimaging Tools (Avants et al., 2010; Avants et al., 2011).”
MethodSun, D., van Erp, T. G. M., Thompson, P. M., Bearden, C. E., Daley, M., Kushan, L., Hardt, M. E., Nuechterlein, K. H., Toga, A. W., & Cannon, T. D. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2009.07.019 · Cited by 148 · cited 4×
“For example, studies using structural MRI report a performance rate that ranges from 54 to 91% (Castellani et al., 2012; Davatzikos et al., 2005; Greenstein et al., 2012; Karageorgiou et al., 2011; Kasparek et al., 2011; Kawasaki et al., 2007; Mandl et al., 2013; Mourao-Miranda et al., 2012; Nieuwenhuis et al., 2012;…”
BackgroundInfluentialThe predictive power of structural MRI in Autism diagnosis
Katuwal, G. J., Cahill, N. D., Baum, S. A., & Michael, A. M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319338 · Cited by 98
Cited by
Pisner, D. A., & Schnyer, D. M. (2020) · Machine Learning · doi:10.1016/b978-0-12-815739-8.00006-7 · Cited by 1,004
Automatic Diagnosis of Schizophrenia in EEG Signals Using CNN-LSTM Models
Shoeibi, A., Sadeghi, D., Moridian, P., Ghassemi, N., Heras, J., Alizadehsani, R., Khadem, A., Kong, Y., Nahavandi, S., Zhang, Y.-D., et al. (2021) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2021.777977 · Cited by 197
“Structural Magnetic Resonance Imaging (sMRI) and DTI-MRI are among the most important modalities of structural neuroimaging, providing important information regarding brain structure to specialist physicians [10], [11], [12].”
BackgroundTowards a brain‐based predictome of mental illness
Rashid, B., & Calhoun, V. (2020) · Human Brain Mapping · doi:10.1002/hbm.25013 · Cited by 167
Sadeghi, D., Shoeibi, A., Ghassemi, N., Moridian, P., Khadem, A., Alizadehsani, R., Teshnehlab, M., Gorriz, J. M., Khozeimeh, F., Zhang, Y.-D., et al. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105554 · Cited by 164
Computing schizophrenia: ethical challenges for machine learning in psychiatry
Starke, G., De Clercq, E., Borgwardt, S., & Elger, B. S. (2021) · Psychological Medicine · doi:10.1017/s0033291720001683 · Cited by 62
“…several groups have shown that ML can distinguish non-medicated, first-episode patients with schizophrenia from healthy controls using volumetric MRI data (Chin, You, Meng, Zhou, & Sim, 2018; Gould et al., 2014; Haijma et al., 2013; Lee et al., 2018; Rozycki et al., 2018; Xiao et al., 2019).”
Metadata
- Authors
- Lee, J., Chon, M.-W., Kim, H., Rathi, Y., Bouix, S., Shenton, M. E., & Kubicki, M.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2018
- Volume
- 18
- Pages
- 467-474
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2790879392
- Cited by
- 36
- References
- 12
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.