The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Fundamental limits of spatial resolution in PET
Open accessAbstract
The fundamental limits of spatial resolution in positron emission tomography (PET) have been understood for many years. The physical size of the detector element usually plays the dominant role in determining resolution, but the combined contributions from acollinearity, positron range, penetration into the detector ring, and decoding errors in the detector modules often combine to be of similar size. In addition, the sampling geometry and statistical noise further degrade the effective resolution. This paper describes quantitatively describes these effects, discusses potential methods for reducing the magnitude of these effects, and computes the ultimately achievable spatial resolution for clinical and pre-clinical PET cameras.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levin, C. S., & Hoffman, E. J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/019 · Cited by 551
Jong, H. W. A. M. D., Velden, F. H. P. V., Kloet, R. W., Buijs, F. L., Boellaard, R., & Lammertsma, A. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/019 · Cited by 349
Modeling and incorporation of system response functions in 3-D whole body PET
Alessio, A. M., Kinahan, P. E., & Lewellen, T. K. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.873222 · Cited by 176
PET/MRI hybrid imaging: devices and initial results
Pichler, B. J., Judenhofer, M. S., & Wehrl, H. F. (2008) · European Radiology · doi:10.1007/s00330-008-0857-5 · Cited by 133
Compensation for crystal penetration in high resolution positron tomography
Huesman, R. H., Salmeron, E. M., & Baker, J. R. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34612 · Cited by 37
Cited by
Pre-metastatic niches: organ-specific homes for metastases
Peinado, H., Zhang, H., Matei, I. R., Costa-Silva, B., Hoshino, A., Rodrigues, G., Psaila, B., Kaplan, R. N., Bromberg, J. F., Kang, Y., et al. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.6 · Cited by 1,889
Gold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
The hallmarks of successful anticancer immunotherapy
Galluzzi, L., Chan, T. A., Kroemer, G., Wolchok, J. D., & López-Soto, A. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aat7807 · Cited by 575
Neuroinflammation in Neurodegenerative Disorders-a Review
Schain, M., & Kreisl, W. C. (2017) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-017-0733-2 · Cited by 301
Comparison of Gallium-68 and Fluorine-18 imaging characteristics in positron emission tomography
Sanchez-Crespo, A. (2013) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2012.06.034 · Cited by 276
Metadata
- Authors
- Moses, W. W.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 648
- Pages
- S236-S240
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W2075119726
- Cited by
- 565
- References
- 5
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fundamental limits of spatial resolution in PET. https://app.cochat.ai/papers/10.1016/j.nima.2010.11.092
- The paper
- Moses, W. W. (2011). Fundamental limits of spatial resolution in PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/j.nima.2010.11.092
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.