CoChat

The DISCOVER Study 3-Year Results

Open access
Ehlers, Justis P., Modi, Yasha S., Pecen, Paula E., Goshe, Jeff, Dupps, William J., Rachitskaya, Aleksandra, Sharma, Sumit, Yuan, Alex, Singh, Rishi, Kaiser, Peter K., Reese, Jamie L., Calabrise, Carmen, Watts, Allison, Srivastava, Sunil K. · 2018 · Ophthalmology
Cited by 146

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective To report the three-year assessment of feasibility and utility of microscope integrated intraoperative optical coherence tomography (iOCT) during ophthalmic surgery. Design Prospective, consecutive, case series Participants Adult subjects undergoing incisional ophthalmic surgery with intraoperative OCT imaging that consented to be enrolled in the Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery (DISCOVER) study. Methods The DISCOVER study is a single-site, multi-surgeon, IRB-approved investigational device prospective study. Participants included patients undergoing anterior or posterior segment surgery and underwent iOCT imaging with one of three prototype microscope-integrated iOCT systems (i.e., Zeiss Rescan 700, Leica EnFocus, Cole Eye iOCT system). Clinical characteristics were documented, iOCT was directed by the operating surgeon at predetermined surgical time points, and each surgeon completed a questionnaire after surgery to evaluate the utility of iOCT during surgery. Outcomes 1. Feasibility of iOCT based ability to obtain an OCT image during surgery. 2. Utility of iOCT based on surgeon reporting during surgery Results A total of 837 eyes (244 anterior segment and 593 posterior segment cases) were enrolled in the DISCOVER study. IOCT demonstrated feasibility with successful image acquisition in 820 (98.0%, CI: 96.8–98.8%) eyes. In 106 (43.4%, CI: 37.1–49.9) anterior segment cases, the surgeons indicated that the iOCT information impacted their surgical decision-making and altered the procedure. In posterior segment procedures, surgeons reported iOCT provided altered surgical decision-making during the procedure in 173 (29.2%, CI: 25.5–33.0%) cases. Conclusions The DISCOVER iOCT study demonstrates both generalized feasibility and utility based on the surgeon-reported impact on surgical decision-making. This large-scale study confirms similar findings of other studies on the potential value and impact of iOCT on ophthalmic surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2017.12.037

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 146

Metadata

Authors
Ehlers, J. P., Modi, Y. S., Pecen, P. E., Goshe, J., Dupps, W. J., Rachitskaya, A., Sharma, S., Yuan, A., Singh, R., Kaiser, P. K., Reese, J. L., Calabrise, C., Watts, A., & Srivastava, S. K.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2018-07
Volume
125
Issue
7
Pages
1014-1027
ISSN
0161-6420 (ISSN-L)
OpenAlex
W2786458964
Cited by
146
References
2
FWCI
5.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.