Cited by 24Terahertz technology and applicationsSpectroscopy and Laser ApplicationsMicrowave and Dielectric Measurement Techniques

Practical method to estimate the standard deviation in absorption coefficients measured with THz time-domain spectroscopy

Open access
Tripathi, Saroj R., Aoki, Makoto, Mochizuki, Kento, Hosako, Iwao, Asahi, Toshiaki, Hiromoto, Norihisa·2010·Optics Communications

Integrity signals

Registry

Crossref · 10.1016/j.optcom.2010.02.008

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

1 of the 14 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Tripathi, S. R., Aoki, M., Mochizuki, K., Hosako, I., Asahi, T., & Hiromoto, N.
Affiliations
  • Shizuoka University (JP)
  • National Institute of Information and Communications Technology (JP)
  • JX Advanced Metals Corporation (Japan) (JP)
Corresponding author
Hiromoto, Norihisa
Venue
Optics Communications
Publisher
Elsevier BV
Published
2010-06
Volume
283
Issue
12
Pages
2488-2491
ISSN
0030-4018 (ISSN-L)
OpenAlex
W2020347859
Cited by
24
References
14
Citations by year
2026: 1 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 4 · 2012: 3
FWCI
3.53
Type
journal article
Language
en
Open access
Locations
  • Optics Communications (publishedVersion)
  • Institutional Repositories DataBase (IRDB) (acceptedVersion)
  • Shizuoka University Repository (Shizuoka University) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
Keywords
terahertz time-domain spectroscopy, absorption coefficient, standard deviation estimation, measurement error, optical transmittance, noise floor, optical constants, refractive index, statistical error analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review