Particle image velocimetry - Classical operating rules from today’s perspective
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Over the last four decades, particle image velocimetry (PIV) has evolved into a powerful and significant measurement technique. The technique has been applied to many areas of fluid mechanics and the accuracy and resolution has been greatly improved over the years. This was made possible by the creativity, enthusiasm and commitment of the developers, but also by the technical achievements in the field of tracer particles, light sources, recording systems, algorithms and computer power. Although time-resolved volumetric PIV measurements are possible today, the majority of measurements are still performed using planar PIV techniques for good reasons. First, planar PIV is rather simple to both install and use and the data is processed quickly and robustly. Second, in many cases planar PIV already provides the desired data to answer scientific questions. Due to the persistent interest in using planar PIV, it is the intention of this review to consider some classical operating rules from today’s perspective and to prove their validity. This may seem needless at first glance. However, it should be noted that once a technique has been established, the basic aspects are generally taken for granted. Therefore, a critical look from time to time is advisable to check whether the concepts are still valid or whether changes are necessary. Furthermore, we intend to deduce under which conditions the use of more complicated techniques pays off.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle Image Velocimetry: A Practical Guide
Raffel, M., Willert, C. E., Scarano, F., Kähler, C. J., Wereley, S. T., & Kompenhans, J. (2018) · doi:10.1007/978-3-319-68852-7 · Cited by 5,049
Self-citationThe structure of turbulent boundary layers
Kline, S. J., Reynolds, W. C., Schraub, F. A., & Runstadler, P. W. (1967) · Journal of Fluid Mechanics · doi:10.1017/s0022112067001740 · Cited by 3,550
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Reynolds, O. (1883) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1883.0029 · Cited by 2,262
Digital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991
Springer Handbook of Experimental Fluid Mechanics
(2007) · Springer handbooks · doi:10.1007/978-3-540-30299-5 · Cited by 1,718
Fundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425
Tomographic particle image velocimetry
Elsinga, G. E., Scarano, F., Wieneke, B., & van Oudheusden, B. W. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0212-z · Cited by 1,251
Universal outlier detection for PIV data
Westerweel, J., & Scarano, F. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0016-6 · Cited by 1,239
Theory of cross-correlation analysis of PIV images
Keane, R. D., & Adrian, R. J. (1992) · Flow Turbulence and Combustion · doi:10.1007/bf00384623 · Cited by 1,227
A particle image velocimetry system for microfluidics
Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J., & Adrian, R. J. (1998) · Experiments in Fluids · doi:10.1007/s003480050235 · Cited by 1,174
Iterative image deformation methods in PIV
Scarano, F. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/1/201 · Cited by 842
Optimization of particle image velocimeters. I. Double pulsed systems
Keane, R. D., & Adrian, R. J. (1990) · Measurement Science and Technology · doi:10.1088/0957-0233/1/11/013 · Cited by 816
PIV uncertainty quantification from correlation statistics
Wieneke, B. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/074002 · Cited by 808
PIV measurements of a microchannel flow
Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (1999) · Experiments in Fluids · doi:10.1007/s003480050366 · Cited by 802
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Shake-The-Box: Lagrangian particle tracking at high particle image densities
Schanz, D., Gesemann, S., & Schröder, A. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2157-1 · Cited by 717
Maas, H. G., Gruen, A., & Papantoniou, D. (1993) · Experiments in Fluids · doi:10.1007/bf00190953 · Cited by 633
Stereoscopic particle image velocimetry
Prasad, A. K. (2000) · Experiments in Fluids · doi:10.1007/s003480000143 · Cited by 620
Scarano, F. (2010) · Encyclopedia of Aerospace Engineering · doi:10.1002/9780470686652.eae074 · Cited by 579
A PIV Algorithm for Estimating Time-Averaged Velocity Fields
Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (2000) · Journal of Fluids Engineering · doi:10.1115/1.483256 · Cited by 499
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W. (1992) · Experiments in Fluids · doi:10.1007/bf00218156 · Cited by 493
Westerweel, J., Dabiri, D., & Gharib, M. (1997) · Experiments in Fluids · doi:10.1007/s003480050082 · Cited by 476
Cierpka, C., & Kähler, C. J. (2012) · Journal of Visualization · doi:10.1007/s12650-011-0107-9 · Cited by 450
Self-citationOlsen, M. G., & Adrian, R. J. (2000) · Experiments in Fluids · doi:10.1007/s003480070018 · Cited by 448
Digital particle image velocimetry: theory and application
Westerweel, J. (1993) · Research Repository (Delft University of Technology) · Cited by 415
Stereoscopic digital particle image velocimetry for application in wind tunnel flows
Willert, C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/010 · Cited by 387
Recent Advances in Micro-Particle Image Velocimetry
Wereley, S. T., & Meinhart, C. D. (2010) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-121108-145427 · Cited by 356
Elkins, C. J., & Alley, M. T. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0383-2 · Cited by 340
Dynamic ranges of velocity and spatial resolution of particle image velocimetry
Adrian, R. J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/003 · Cited by 328
Stereoscopic particle image velocimetry applied to liquid flows
Prasad, A. K., & Adrian, R. J. (1993) · Experiments in Fluids · doi:10.1007/bf00195595 · Cited by 317
On the resolution limit of digital particle image velocimetry
Kähler, C. J., Scharnowski, S., & Cierpka, C. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1280-x · Cited by 311
Self-citationOn the uncertainty of digital PIV and PTV near walls
Kähler, C. J., Scharnowski, S., & Cierpka, C. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1307-3 · Cited by 294
Self-citationLow cost, high resolution DPIV for measurement of turbulent fluid flow
Fincham, A. M., & Spedding, G. R. (1997) · Experiments in Fluids · doi:10.1007/s003480050135 · Cited by 292
PIV uncertainty quantification by image matching
Sciacchitano, A., Wieneke, B., & Scarano, F. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/4/045302 · Cited by 286
Main results of the third international PIV Challenge
Stanislas, M., Okamoto, K., Kähler, C. J., Westerweel, J., & Scarano, F. (2008) · Experiments in Fluids · doi:10.1007/s00348-008-0462-z · Cited by 284
Self-citationCharonko, J., & Vlachos, P. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/6/065301 · Cited by 278
Uncertainty quantification in particle image velocimetry
Sciacchitano, A. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab1db8 · Cited by 268
Super-resolution particle imaging velocimetry
Keane, R. D., Adrian, R. J., & Zhang, Y. (1995) · Measurement Science and Technology · doi:10.1088/0957-0233/6/6/013 · Cited by 251
Hart, D. P. (2000) · Laser Techniques Applied to Fluid Mechanics · doi:10.1007/978-3-642-56963-0_2 · Cited by 251
Collaborative framework for PIV uncertainty quantification: comparative assessment of methods
Sciacchitano, A., Neal, D. R., Smith, B. L., Warner, S. O., Vlachos, P. P., Wieneke, B., & Scarano, F. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/074004 · Cited by 244
Stereoscopic particle image velocimetry
Arroyo, M. P., & Greated, C. A. (1991) · Measurement Science and Technology · doi:10.1088/0957-0233/2/12/012 · Cited by 243
Phase-conjugate holographic system for high-resolution particle-image velocimetry
Barnhart, D. H., Adrian, R. J., & Papen, G. C. (1994) · Applied Optics · doi:10.1364/ao.33.007159 · Cited by 236
On the use of helium-filled soap bubbles for large-scale tomographic PIV in wind tunnel experiments
Scarano, F., Ghaemi, S., Caridi, G. C. A., Bosbach, J., Dierksheide, U., & Sciacchitano, A. (2015) · Experiments in Fluids · doi:10.1007/s00348-015-1909-7 · Cited by 228
Main results of the 4th International PIV Challenge
Kähler, C. J., Astarita, T., Vlachos, P. P., Sakakibara, J., Hain, R., Discetti, S., Foy, R. L., & Cierpka, C. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2173-1 · Cited by 225
Self-citationTurbulent flow measurement in a square duct with hybrid holographic PIV
Zhang, J., Tao, B., & Katz, J. (1997) · Experiments in Fluids · doi:10.1007/s003480050124 · Cited by 185
Comparison of CCD, CMOS and intensified cameras
Hain, R., Kähler, C. J., & Tropea, C. D. (2007) · Experiments in Fluids · doi:10.1007/s00348-006-0247-1 · Cited by 181
Self-citationGeneration and control of tracer particles for optical flow investigations in air
Kähler, C., Sammler, B., & Kompenhans, J. (2002) · Experiments in Fluids · doi:10.1007/s00348-002-0492-x · Cited by 165
Self-citationMulti-frame pyramid correlation for time-resolved PIV
Sciacchitano, A., Scarano, F., & Wieneke, B. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1345-x · Cited by 163
Higher order multi-frame particle tracking velocimetry
Cierpka, C., Lütke, B., & Kähler, C. J. (2013) · Experiments in Fluids · doi:10.1007/s00348-013-1533-3 · Cited by 161
Self-citationLarge scale particle image velocimetry with helium filled soap bubbles
Bosbach, J., Kühn, M., & Wagner, C. D. (2008) · Experiments in Fluids · doi:10.1007/s00348-008-0579-0 · Cited by 155
Lawson, N. J., & Wu, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/009 · Cited by 143
Schlieren “PIV” for turbulent flows
Jonassen, D. R., Settles, G. S., & Tronosky, M. D. (2005) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2005.04.004 · Cited by 138
Super-resolution PIV by recursive local-correlation
Hart, D. P. (2000) · Journal of Visualization · doi:10.1007/bf03182411 · Cited by 135
Brücker, C. (1995) · Experiments in Fluids · doi:10.1007/bf00196474 · Cited by 131
Analysis of weighting windows for image deformation methods in PIV
Astarita, T. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0314-2 · Cited by 130
Uncertainty on PIV mean and fluctuating velocity due to bias and random errors
Wilson, B. M., & Smith, B. L. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/3/035302 · Cited by 129
Three-dimensional particle velocimetry
Hinsch, K. (1995) · Measurement Science and Technology · doi:10.1088/0957-0233/6/6/012 · Cited by 127
Three-dimensional particle image velocimetry: error analysis of stereoscopic techniques
Lawson, N. J., & Wu, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/8/010 · Cited by 125
Ebbers, T., Wigström, L., Bolger, A. F., Wranne, B., & Karlsson, M. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1468866 · Cited by 125
3D scanning PIV applied to an air flow in a motored engine using digital high-speed video
Brücker, C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/011 · Cited by 118
Volumetric velocimetry for fluid flows
Discetti, S., & Coletti, F. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaa571 · Cited by 114
Full-field bubbly flow velocity measurements using a multiframe particle tracking technique
Hassan, Y. A., & Canaan, R. E. (1991) · Experiments in Fluids · doi:10.1007/bf00226565 · Cited by 112
Xue, Z., Charonko, J., & Vlachos, P. P. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/11/115301 · Cited by 111
An adaptive sampling and windowing interrogation method in PIV
Theunissen, R., Scarano, F., & Riethmuller, M. L. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/18/1/034 · Cited by 108
Collaborative framework for PIV uncertainty quantification: the experimental database
Neal, D. R., Sciacchitano, A., Smith, B. L., & Scarano, F. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/074003 · Cited by 105
Optimization procedure for pulse separation in cross-correlation PIV
Boillot, A., & Prasad, A. K. (1996) · Experiments in Fluids · doi:10.1007/bf00193911 · Cited by 104
Rossi, M., Segura, R., Cierpka, C., & Kähler, C. J. (2011) · Experiments in Fluids · doi:10.1007/s00348-011-1194-z · Cited by 98
Self-citationHigh-speed particle image velocimetry for the efficient measurement of turbulence statistics
Willert, C. E. (2015) · Experiments in Fluids · doi:10.1007/s00348-014-1892-4 · Cited by 97
Reynolds stress estimation up to single-pixel resolution using PIV-measurements
Scharnowski, S., Hain, R., & Kähler, C. J. (2011) · Experiments in Fluids · doi:10.1007/s00348-011-1184-1 · Cited by 96
Self-citationRobotic volumetric PIV of a full-scale cyclist
Jux, C., Sciacchitano, A., Schneiders, J. F. G., & Scarano, F. (2018) · Experiments in Fluids · doi:10.1007/s00348-018-2524-1 · Cited by 92
Time-resolved particle image velocimetry used in the investigation of cavitation bubble dynamics
Vogel, A., & Lauterborn, W. H. (1988) · Applied Optics · doi:10.1364/ao.27.001869 · Cited by 82
Elimination of peak-locking error in PIV analysis using the correlation mapping method
Chen, J., & Katz, J. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/8/010 · Cited by 72
Heisel, M., Dasari, T., Liu, Y., Hong, J., Coletti, F., & Guala, M. (2018) · Journal of Fluid Mechanics · doi:10.1017/jfm.2018.759 · Cited by 70
Turbulence statistics from optical whole-field measurements in particle-laden turbulence
Poelma, C., Westerweel, J., & Ooms, G. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0118-9 · Cited by 68
Mullin, J. A., & Dahm, W. J. A. (2006) · Physics of Fluids · doi:10.1063/1.2166447 · Cited by 64
Mullin, J. A., & Dahm, W. J. A. (2004) · Experiments in Fluids · doi:10.1007/s00348-004-0898-8 · Cited by 64
Koochesfahani, M., & Nocera, D. G. (2007) · Cited by 54
Cuvier, C., Srinath, S., Stanislas, M., Foucaut, J.-M., Laval, J.-P., Kähler, C. J., Hain, R., Scharnowski, S., Schröder, A., Geisler, R., et al. (2017) · Journal of Turbulence · doi:10.1080/14685248.2017.1342827 · Cited by 53
Self-citationEstimation and optimization of loss-of-pair uncertainties based on PIV correlation functions
Scharnowski, S., & Kähler, C. J. (2016) · Experiments in Fluids · doi:10.1007/s00348-015-2108-2 · Cited by 48
Self-citationOn the loss-of-correlation due to PIV image noise
Scharnowski, S., & Kähler, C. J. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2203-z · Cited by 42
Self-citationOn the effect of curved streamlines on the accuracy of PIV vector fields
Scharnowski, S., & Kähler, C. J. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1435-9 · Cited by 40
Self-citationFlow visualization by mobile phone cameras
Cierpka, C., Hain, R., & Buchmann, N. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2192-y · Cited by 40
"Postage-Stamp PIV:" Small Velocity Fields at 400 kHz for Turbulence Spectra Measurements
Beresh, S. J., Henfling, J. F., Spillers, R. W., & Spitzer, S. M. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa9f79 · Cited by 38
CORRECTION METHOD OF ERRONEOUS VECTORS IN PIV
FUJITA, I., & Kaizu, T. (1995) · Journal of Flow Visualization and Image Processing · doi:10.1615/jflowvisimageproc.v2.i2.60 · Cited by 31
André, M. A., Burns, R. A., Danehy, P. M., et al. (2017) · Experiments in Fluids · doi:10.1007/s00348-017-2470-3 · Cited by 18
High accuracy measurement of magnification for monocular PIV
Discetti, S., & Adrian, R. J. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/11/117001 · Cited by 18
Raffel, M., Hernandez-Rivera, R., Heine, B., Schröder, A., & Mülleners, K. (2011) · Experiments in Fluids · doi:10.1007/s00348-011-1058-6 · Cited by 17
On dealing with multiple correlation peaks in PIV
Masullo, A., & Theunissen, R. (2018) · Experiments in Fluids · doi:10.1007/s00348-018-2542-z · Cited by 13
Metadata
- Authors
- Scharnowski, S., & Kähler, C. J.
- Venue
- Optics and Lasers in Engineering
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 135
- Pages
- 106185
- ISSN
- 0143-8166 (ISSN-L)
- OpenAlex
- W3032922380
- Cited by
- 166
- References
- 89
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.