Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Accumulating evidence suggests that characteristics of pre-treatment FDG-PET could be used as prognostic factors to predict outcomes in different cancer sites. Current risk analyses are limited to visual assessment or direct uptake value measurements. We are investigating intensity-volume histogram metrics and shape and texture features extracted from PET images to predict patient's response to treatment. These approaches were demonstrated using datasets from cervix and head and neck cancers, where AUC of 0.76 and 1.0 were achieved, respectively. The preliminary results suggest that the proposed approaches could potentially provide better tools and discriminant power for utilizing functional imaging in clinical prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Fundamentals of digital image processing
Jain, A. K. (1988) · Cited by 7,111
Kernel Methods for Pattern Analysis
Shawe-Taylor, J., & Cristianini, N. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511809682 · Cited by 6,587
The quickhull algorithm for convex hulls
Barber, C. B., Dobkin, D. P., & Huhdanpaa, H. (1996) · ACM Transactions on Mathematical Software · doi:10.1145/235815.235821 · Cited by 5,359
Fundamentals of digital image processing
(1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(89)90041-8 · Cited by 4,677
Nonparametric Statistical Methods.
Knott, M., Hollander, M., & Wolfe, D. A. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344557 · Cited by 2,662
Nonparametric Statistical Methods
Ramsey, P. H. (2000) · Technometrics · doi:10.1080/00401706.2000.10486020 · Cited by 1,673
Texture analysis of SAR sea ice imagery using gray level co-occurrence matrices
Soh, L.-K., & Tsatsoulis, C. (1999) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.752194 · Cited by 1,223
CERR: A computational environment for radiotherapy research
Deasy, J. O., Blanco, A. I., & Clark, V. H. (2003) · Medical Physics · doi:10.1118/1.1568978 · Cited by 872
Self-citationThe applications of PET in clinical oncology.
Strauss, L. G., & Conti, P. S. (1991) · PubMed · Cited by 844
(2005) · PubMed · Cited by 612
A support vector machine approach for detection of microcalcifications
El-Naqa, I., Yang, Y., Wernick, M. N., Galatsanos, N. P., & Nishikawa, R. M. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806569 · Cited by 571
Self-citationImpact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancer
Bradley, J., Thorstad, W. L., Mutic, S., Miller, T. R., Dehdashti, F., Siegel, B. A., Bosch, W., & Bertrand, R. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.044 · Cited by 556
Self-citationSteel, G. G. (1997) · Cited by 490
Yu, S., & Guan, L. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836371 · Cited by 324
Miller, T. R., & Grigsby, P. W. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02705-0 · Cited by 284
Self-citationGradient and texture analysis for the classification of mammographic masses
Desautels, J. E. L., Rangayyan, R., & Mudigonda, N. R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887618 · Cited by 281
Brun, E., Kjellén, E., Tennvall, J., Ohlsson, T., Sandell, A., Perfekt, R., Perfekt, R., Wennerberg, J., & Strand, S. E. (2002) · Head & Neck · doi:10.1002/hed.10037 · Cited by 251
C. Joiner, M., & van der KogeJ. l, A. (2024) · CRC Press eBooks · doi:10.1201/9781003278337 · Cited by 244
Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion
Riegel, A. C., Berson, A. M., Destian, S., Ng, T., Tena, L. B., Mitnick, R. J., & Wong, P. S. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.014 · Cited by 242
Dependence of FDG uptake on tumor microenvironment
Pugachev, A., Ruan, S., Carlin, S., Larson, S. M., Campa, J., Ling, C. C., & Humm, J. L. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.02.009 · Cited by 192
Multivariable modeling of radiotherapy outcomes, including dose–volume and clinical factors
El Naqa, I., Bradley, J., Blanco, A. I., Lindsay, P. E., Vicic, M., Hope, A., & Deasy, J. O. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.11.022 · Cited by 171
Self-citationHicks, R. J., Mac Manus, M. P., Matthews, J. P., Hogg, A., Binns, D., Rischin, D., Ball, D. L., & Peters, L. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.03.036 · Cited by 164
Kalff, V., Duong, C., Drummond, E. G. P., Matthews, J. P., & Hicks, R. J. (2006) · PubMed · Cited by 142
Concurrent multimodality image segmentation by active contours for radiotherapy treatment planninga)
Naqa, I. E., Yang, D., Apte, A., Khullar, D., Mutic, S., Zheng, J., Bradley, J. D., Grigsby, P. W., & Deasy, J. O. (2007) · Medical Physics · doi:10.1118/1.2799886 · Cited by 123
Self-citationAlvarenga, A. V., Pereira, W. C. D. A., Infantosi, A. F. C., & de Azevedo, C. M. (2007) · Medical Physics · doi:10.1118/1.2401039 · Cited by 118
Grabenbauer, G. G., Steininger, H., Meyer, M. F., Fietkau, R., Brunner, T. B., Heinkelmann, P., Hornung, J. A., Iro, H., Spitzer, W. J., Distel, L. V., et al. (1998) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(98)00016-4 · Cited by 84
2-Deoxy-2-[18F] fluoro-D-glucose uptake and correlation to intratumoral heterogeneity.
Henriksson, E., Kjellén, E., Wahlberg, P., Ohlsson, T. G., Wennerberg, J. P., & Brun, E. (2007) · PubMed · Cited by 73
O’Sullivan, F. (2005) · Biostatistics · doi:10.1093/biostatistics/kxi010 · Cited by 70
A statistical measure of tissue heterogeneity with application to 3D PET sarcoma data
O’Sullivan, F. (2003) · Biostatistics · doi:10.1093/biostatistics/4.3.433 · Cited by 69
FDG-PET in monitoring therapy of breast cancer
Biersack, H. J., Bender, H., & PALMEDO, H. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1533-x · Cited by 49
Positron-emission tomography for head and neck cancer
Greven, K. M. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.12.005 · Cited by 25
Texture analysis of differently reconstructed PET images
Lucht, R., Brix, G., & Lorenz, W. J. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/10/025 · Cited by 9
Cited by
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
“, mean, median, min, max, range, skewness, kurtosis), but also more complex values, such as metabolic volume above an absolute SUV of 5 or the fraction of highdensity tissue measured with CT [60,61].”
BackgroundApplications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Metadata
- Authors
- El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., Thorstad, W. L., & Deasy, J. O.
- Venue
- Pattern Recognition
- Publisher
- Elsevier BV
- Published
- 2009-06
- Volume
- 42
- Issue
- 6
- Pages
- 1162-1171
- ISSN
- 0031-3203 (ISSN-L)
- OpenAlex
- W2074445922
- Cited by
- 480
- References
- 35
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.