Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Accumulating evidence suggests that characteristics of pre-treatment FDG-PET could be used as prognostic factors to predict outcomes in different cancer sites. Current risk analyses are limited to visual assessment or direct uptake value measurements. We are investigating intensity-volume histogram metrics and shape and texture features extracted from PET images to predict patient's response to treatment. These approaches were demonstrated using datasets from cervix and head and neck cancers, where AUC of 0.76 and 1.0 were achieved, respectively. The preliminary results suggest that the proposed approaches could potentially provide better tools and discriminant power for utilizing functional imaging in clinical prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Fundamentals of digital image processing
Jain, A. K. (1988) · Cited by 7,111
Kernel Methods for Pattern Analysis
Shawe-Taylor, J., & Cristianini, N. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511809682 · Cited by 6,587
The quickhull algorithm for convex hulls
Barber, C. B., Dobkin, D. P., & Huhdanpaa, H. (1996) · ACM Transactions on Mathematical Software · doi:10.1145/235815.235821 · Cited by 5,359
Fundamentals of digital image processing
(1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(89)90041-8 · Cited by 4,677
Nonparametric Statistical Methods.
Knott, M., Hollander, M., & Wolfe, D. A. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344557 · Cited by 2,662
Nonparametric Statistical Methods
Ramsey, P. H. (2000) · Technometrics · doi:10.1080/00401706.2000.10486020 · Cited by 1,673
Texture analysis of SAR sea ice imagery using gray level co-occurrence matrices
Soh, L.-K., & Tsatsoulis, C. (1999) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.752194 · Cited by 1,223
Cited by
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
“, mean, median, min, max, range, skewness, kurtosis), but also more complex values, such as metabolic volume above an absolute SUV of 5 or the fraction of highdensity tissue measured with CT [60,61].”
BackgroundApplications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Vallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897
Self-citationAssessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall, F., Yip, C. S. P., Ljungqvist, G., Selmi, M., Ng, F., Sanghera, B., Ganeshan, B., Miles, K. A., Cook, G. J., & Goh, V. (2012) · Insights into Imaging · doi:10.1007/s13244-012-0196-6 · Cited by 878
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
The Potential of Radiomic-Based Phenotyping in Precision Medicine: A Review
Aerts, H. J. W. L. (2016) · JAMA Oncology · doi:10.1001/jamaoncol.2016.2631 · Cited by 669
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Self-citationIntrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Radiomics strategies for risk assessment of tumour failure in head-and-neck cancer
Vallières, M., Kay-Rivest, E., Perrin, L. J., Liem, X., Furstoss, C., Aerts, H. J. W. L., Khaouam, N., Nguyen-Tan, P. F., Wang, C.-S., Sultanem, K., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-10371-5 · Cited by 542
Self-citationQuantifying tumour heterogeneity in 18F-FDG PET/CT imaging by texture analysis
Chicklore, S., Goh, V., Siddique, M., Roy, A., Marsden, P. K., & Cook, G. J. R. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2247-0 · Cited by 488
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Self-citationCharacterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Hatt, M., Majdoub, M., Vallières, M., Tixier, F., Le Rest, C. C., Groheux, D., Hindié, E., Martineau, A., Pradier, O., Hustinx, R., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.144055 · Cited by 438
Self-citationRadiomic feature clusters and Prognostic Signatures specific for Lung and Head & Neck cancer
Parmar, C., Leijenaar, R. T. H., Grossmann, P., Rios Velazquez, E., Bussink, J., Rietveld, D., Rietbergen, M. M., Haibe-Kains, B., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep11044 · Cited by 434
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Cook, G. J. R., Yip, C., Siddique, M., Goh, V., Chicklore, S., Roy, A., Marsden, P., Ahmad, S., & Landau, D. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107375 · Cited by 394
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Orlhac, F., Boughdad, S., Philippe, C., Stalla-Bourdillon, H., Nioche, C., Champion, L., Soussan, M., Frouin, F., Frouin, V., & Buvat, I. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.199935 · Cited by 393
Radiomics: from qualitative to quantitative imaging
Rogers, W., Thulasi Seetha, S., Refaee, T. A. G., Lieverse, R. I. Y., Granzier, R. W. Y., Ibrahim, A., Keek, S. A., Sanduleanu, S., Primakov, S. P., Beuque, M. P. L., et al. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190948 · Cited by 372
Radiomics: a new application from established techniques
Parekh, V., & Jacobs, M. A. (2016) · Expert Review of Precision Medicine and Drug Development · doi:10.1080/23808993.2016.1164013 · Cited by 369
Orlhac, F., Soussan, M., Maisonobe, J.-A., Garcia, C. A., Vanderlinden, B., & Buvat, I. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.129858 · Cited by 356
Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
False Discovery Rates in PET and CT Studies with Texture Features: A Systematic Review
Chalkidou, A., O’Doherty, M. J., & Marsden, P. K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124165 · Cited by 344
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
A radiogenomic dataset of non-small cell lung cancer
Bakr, S., Gevaert, O., Echegaray, S., Ayers, K., Zhou, M., Shafiq, M., Zheng, H., Benson, J. A., Zhang, W., Leung, A. N. C., et al. (2018) · Scientific Data · doi:10.1038/sdata.2018.202 · Cited by 311
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Voxel size and gray level normalization of CT radiomic features in lung cancer
Shafiq-ul-Hassan, M., Latifi, K., Zhang, G., Ullah, G., Gillies, R., & Moros, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-28895-9 · Cited by 215
Shiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Combined PET/CT image characteristics for radiotherapy tumor response in lung cancer
Vaidya, M., Creach, K. M., Frye, J., Dehdashti, F., Bradley, J. D., & El Naqa, I. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.10.014 · Cited by 201
“, mean and standard deviation) [17,24].”
BackgroundSelf-citationHatt, M., Lee, J. A., Schmidtlein, C. R., Naqa, I. E., Caldwell, C., De Bernardi, E., Lu, W., Das, S., Geets, X., Gregoire, V., et al. (2017) · Medical Physics · doi:10.1002/mp.12124 · Cited by 198
Predicting Response to Neoadjuvant Chemotherapy with PET Imaging Using Convolutional Neural Networks
Ypsilantis, P.-P., Siddique, M., Sohn, H.-M., Davies, A., Cook, G., Goh, V., & Montana, G. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137036 · Cited by 185
van Velden, F. H. P., Cheebsumon, P., Yaqub, M., Smit, E. F., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1845-6 · Cited by 182
“However, preliminary studies already indicated that other measures derived from the CSH, such as the % of volume derived at a fixed % of SUVor % of SUV derived at a fixed % of volume, could be used as a prognostic factor in NSCLC [28] and head and neck cancer [14].”
BackgroundTexture analysis of medical images for radiotherapy applications
Scalco, E., & Rizzo, G. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160642 · Cited by 165
FDG PET/CT radiomics for predicting the outcome of locally advanced rectal cancer
Lovinfosse, P., Polus, M., Van Daele, D., Martinive, P., Daenen, F., Hatt, M., Visvikis, D., Koopmansch, B., Lambert, F., Coimbra, C., et al. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3855-5 · Cited by 165
“deviation (SUVsd), SUV coefficient of variation, skewness and excess kurtosis [26].”
BackgroundRadiomic features analysis in computed tomography images of lung nodule classification
Chen, C.-H., Chang, C.-K., Tu, C.-Y., Liao, W.-C., Wu, B.-R., Chou, K.-T., Chiou, Y.-R., Yang, S.-N., Zhang, G., & Huang, T.-C. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192002 · Cited by 160
PET Radiomics in NSCLC: state of the art and a proposal for harmonization of methodology
Sollini, M., Cozzi, L., Antunovic, L., Chiti, A., & Kirienko, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00426-y · Cited by 158
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.113332 · Cited by 47
“It is also quite possible that alternative, non-SUV measures may be better suited for PETbased assessment of treatment response (27,28).”
BackgroundNakajo, M., Jinguji, M., Nakajo, M., Shinaji, T., Nakabeppu, Y., Fukukura, Y., & Yoshiura, T. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1207-3 · Cited by 32
“More recently, PET image texture analysis was proposed to characterize heterogeneity of tumor FDG uptake [10].”
Background
Metadata
- Authors
- El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., Thorstad, W. L., & Deasy, J. O.
- Venue
- Pattern Recognition
- Publisher
- Elsevier BV
- Published
- 2009-06
- Volume
- 42
- Issue
- 6
- Pages
- 1162-1171
- ISSN
- 0031-3203 (ISSN-L)
- OpenAlex
- W2074445922
- Cited by
- 480
- References
- 35
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.