The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Anomaly detection and critical SCADA parameters identification for wind turbines based on LSTM-AE neural network
Abstract
Abstract Continuous monitoring of wind turbine health conditions using anomaly detection methods can improve the reliability and reduce maintenance costs during operation of wind turbine. Anomaly detection aims at identifying the root causes leading to unexpected changes of product performance. Most existing methods make less use of temporal order of the data and are poor at extracting features from these data. To address these problems, a method based on long short-term memory (LSTM) and auto-encoder (AE) neural network is introduced to assess sequential condition monitoring data of the wind turbine. First, a performance assessment model is constructed using LSTM neural units and AE networks to calculate the performance indices for evaluation of the degree of anomalies in wind turbine performance. Then, an adaptive threshold estimation method based on support vector regression model is developed to identify the abnormal data instances. The mutual information theory is subsequently explored to analyze the relationships between various monitoring parameters and performance abnormal instances to identify critical condition monitoring parameters. The effectiveness of the proposed method has been verified by a case study using real-world wind turbine condition monitoring (CM) data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
LSTM network: a deep learning approach for short‐term traffic forecast
Zhao, Z., Chen, W., Wu, X., Chen, P. C. Y., & Liu, J. (2017) · IET Intelligent Transport Systems · doi:10.1049/iet-its.2016.0208 · Cited by 1,834
Encyclopedia of Structural Health Monitoring
(2009) · Wiley eBooks · doi:10.1002/9780470061626 · Cited by 778
Learning to Monitor Machine Health with Convolutional Bi-Directional LSTM Networks
Zhao, R., Yan, R., Wang, J., & Mao, K. (2017) · Sensors · doi:10.3390/s17020273 · Cited by 741
A sparse auto-encoder-based deep neural network approach for induction motor faults classification
Sun, W., Shao, S., Zhao, R., Yan, R., Zhang, X., & Chen, X. (2016) · Measurement · doi:10.1016/j.measurement.2016.04.007 · Cited by 698
Gan, M., Wang, C., & Zhu, C. (2016) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2015.11.014 · Cited by 550
Fault diagnosis of wind turbine based on Long Short-term memory networks
Lei, J., Liu, C., & Jiang, D. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.10.031 · Cited by 507
Toward a resilient manufacturing system
Zhang, W. J., & van Luttervelt, C. A. (2011) · CIRP Annals · doi:10.1016/j.cirp.2011.03.041 · Cited by 367
Ince, R. A. A., Giordano, B. L., Kayser, C., Rousselet, G. A., Gross, J., & Schyns, P. G. (2017) · Human Brain Mapping · doi:10.1002/hbm.23471 · Cited by 366
An Artificial Neural Network Approach for Early Fault Detection of Gearbox Bearings
Bangalore, P., & Tjernberg, L. B. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2386305 · Cited by 339
Anomaly detection and fault analysis of wind turbine components based on deep learning network
Zhao, H., Liu, H., Hu, W., & Yan, X. (2018) · Renewable Energy · doi:10.1016/j.renene.2018.05.024 · Cited by 301
Self-citationPrognostics and Health Management of Electronics
Pecht, M. (2008) · Encyclopedia of Structural Health Monitoring · doi:10.1002/9780470061626.shm118 · Cited by 287
2011 IEEE International Conference on Prognostics and Health Management
(2010) · IEEE Transactions on Reliability · doi:10.1109/tr.2010.2095274 · Cited by 286
On the principle of design of resilient systems – application to enterprise information systems
Zhang, W. J., & Lin, Y. (2010) · Enterprise Information Systems · doi:10.1080/17517571003763380 · Cited by 283
Tran, V. T., Thom Pham, H., Yang, B.-S., & Tien Nguyen, T. (2012) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2012.02.015 · Cited by 248
Dao, P. B., Staszewski, W. J., Barszcz, T., & Uhl, T. (2018) · Renewable Energy · doi:10.1016/j.renene.2017.06.089 · Cited by 218
Li, S., Liu, G., Tang, X., Lu, J., & Hu, J. (2017) · Sensors · doi:10.3390/s17081729 · Cited by 211
Kandukuri, S. T., Klausen, A., Karimi, H. R., & Robbersmyr, K. G. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.08.061 · Cited by 203
A New Multivariate Approach for Prognostics Based on Extreme Learning Machine and Fuzzy Clustering
Javed, K., Gouriveau, R., & Zerhouni, N. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2378056 · Cited by 189
Xiao, B., Yin, S., & Gao, H. (2017) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2017.2707333 · Cited by 168
Diagnosing wind turbine faults using machine learning techniques applied to operational data
Leahy, K., Hu, R. L., Konstantakopoulos, I. C., Spanos, C. J., & Agogino, A. M. (2016) · IEEE Conference on Prognostics and Health Management · doi:10.1109/icphm.2016.7542860 · Cited by 143
Chen, J., Li, J., Chen, W., Wang, Y., & Jiang, T. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.09.041 · Cited by 133
Feng, Z., Qin, S., & Liang, M. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.06.041 · Cited by 130
Uddin, M. S., & Kumar, S. (2014) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2014.01.073 · Cited by 127
Wang, Z., Liu, Q., Chen, H., & Chu, X. (2020) · International Journal of Production Research · doi:10.1080/00207543.2020.1808261 · Cited by 126
Self-citationSupport vector regression for anomaly detection from measurement histories
Kromanis, R., & Kripakaran, P. (2013) · Advanced Engineering Informatics · doi:10.1016/j.aei.2013.03.002 · Cited by 109
Ageing assessment of a wind turbine over time by interpreting wind farm SCADA data
Dai, J., Yang, W., Cao, J., Liu, D., & Long, X. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.03.097 · Cited by 102
Fault Diagnosis of Advanced Wind Turbine Benchmark using Interval-based ARRs and Observers
Sanchez, H., Escobet, T., Puig, V., & Odgaard, P. F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2399401 · Cited by 101
Habib, K., & Wenzel, H. (2015) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2015.07.064 · Cited by 99
Joint mutual information-based input variable selection for multivariate time series modeling
Han, M., Ren, W., & Liu, X. (2014) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2014.08.011 · Cited by 51
Shahbazi, M., Poure, P., & Saadate, S. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.02.066 · Cited by 41
A divide and conquer approach to anomaly detection, localization and diagnosis
Liu, J., Djurdjanović, D., Marko, K. A., & Ni, J. (2009) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2009.05.016 · Cited by 34
Wang, Z., Ma, H., Chen, H., Yan, B., & Chu, X. (2019) · International Journal of Production Research · doi:10.1080/00207543.2019.1636325 · Cited by 34
Self-citation
Cited by
Li, G., & Jung, J. J. (2023) · Information Fusion · doi:10.1016/j.inffus.2022.10.008 · Cited by 361
Afridi, Y. S., Ahmad, K., & Hassan, L. (2022) · International Journal of Energy Research · doi:10.1002/er.7100 · Cited by 140
Metadata
- Authors
- Chen, H., Liu, H., Chu, X., Liu, Q., & Xue, D.
- Venue
- Renewable Energy
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 172
- Pages
- 829-840
- ISSN
- 0960-1481 (ISSN-L)
- OpenAlex
- W3138430000
- Cited by
- 253
- References
- 33
- FWCI
- 16.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.