The DOI matches its Crossref record; 79 of the 80 references it cites were found in a registry or an index.
Personalized conditioning and its impact on thermal comfort and energy performance – A review
Open accessOverview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Personal conditioning typically targets local discomfort, and hence, results in non-uniform environments [122]: the hands and arms are critical body parts in cool environments, whereas the head and neck are critical body parts in warm environments.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [122]
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“The built environment accounts for 30% of the primary energy use in The Netherlands [1] and 20 – 40% in the EU and the US [2], while about half of this energy is used by HVAC.”
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Thermal comfort: Analysis and applications in environmental engineering
Fanger, P. O. (1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,515
(1998) · eScholarship (California Digital Library) · Cited by 1,934
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733
Thermal comfort and gender: a literature review
Karjalainen, S. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00747.x · Cited by 536
Zhang, H., Arens, E. A., Huizenga, C., & Han, T. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.020 · Cited by 533
Progress in thermal comfort research over the last twenty years
de Dear, R., AKIMOTO, T., Arens, E. A., Brager, G. S., Cândido, C., Cheong, D. K. W., Li, B., Nishihara, N., Sekhar, C., Tanabe, S., et al. (2013) · Indoor Air · doi:10.1111/ina.12046 · Cited by 524
Partial- and whole-body thermal sensation and comfort—Part II: Non-uniform environmental conditions
Arens, E. A., Zhang, H., & Huizenga, C. (2006) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2005.11.027 · Cited by 444
Melikov, A. K. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00284.x · Cited by 401
Human thermal sensation and comfort in transient and non-uniform thermal environments
Zhang, H. (2003) · eScholarship (California Digital Library) · Cited by 394
Partial- and whole-body thermal sensation and comfort— Part I: Uniform environmental conditions
Arens, E. A., Zhang, H., & Huizenga, C. (2006) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2005.11.028 · Cited by 368
Personalized ventilation: evaluation of different air terminal devices
Melikov, A. K., Cermak, R., & Majer, M. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00102-0 · Cited by 335
Revisiting an old hypothesis of human thermal perception: alliesthesia
de Dear, R. (2011) · Building Research & Information · doi:10.1080/09613218.2011.552269 · Cited by 333
Humphreys, M., Rijal, H. B., & Nicol, F. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.01.024 · Cited by 329
Comfort, perceived air quality, and work performance in a low-power task–ambient conditioning system
Zhang, H., Arens, E. A., Kim, D., Buchberger, E., Bauman, F. S., & Huizenga, C. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.016 · Cited by 325
Gender differences in thermoregulation
Kaciuba-Uściłko, H., & Grucza, R. (2001) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/00075197-200111000-00012 · Cited by 290
Are ‘class A’ temperature requirements realistic or desirable?
Arens, E. A., Humphreys, M., de Dear, R., & Zhang, H. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.03.014 · Cited by 260
Comfort under personally controlled air movement in warm and humid environments
Zhai, Y., Zhang, H., Zhang, Y., Pasut, W., Arens, E., & Meng, Q. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.03.022 · Cited by 231
Adiposity and human regional body temperature
Savastano, D. M., Gorbach, A. M., Eden, H. S., Brady, S. M., Reynolds, J. C., & Yanovski, J. A. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.27567 · Cited by 223
Wang, D., Zhang, H., Arens, E. A., & Huizenga, C. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.06.035 · Cited by 221
Thermal comfort and productivity - Evaluation of workplace environment in a task conditioned office
AKIMOTO, T., Tanabe, S., Yanai, T., & Sasaki, M. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.022 · Cited by 217
Energy saving and improved comfort by increased air movement
Schiavon, S., & Melikov, A. K. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.05.001 · Cited by 214
Skin and core temperature response to partial- and whole-body heating and cooling
Huizenga, C., Zhang, H., Arens, E., & Wang, D. (2004) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2004.08.024 · Cited by 213
Human response to personalized ventilation and mixing ventilation
Kaczmarczyk, J., Melikov, A. K., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00300.x · Cited by 213
Schellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2012.07.008 · Cited by 206
The skin’s role in human thermoregulation and comfort
Arens, E. A., & Zhang, H. (2006) · Elsevier eBooks · doi:10.1533/9781845692261.3.560 · Cited by 205
Gao, C., Kuklane, K., Wang, F., & Holmér, I. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00778.x · Cited by 187
A study of occupant cooling by personally controlled air movement
Arens, E. A., Xu, T. T., Miura, K., Hui, Z., Fountain, M., & Bauman, F. S. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00025-x · Cited by 150
Energy analysis of the personalized ventilation system in hot and humid climates
Schiavon, S., Melikov, A. K., & Sekhar, C. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.11.009 · Cited by 149
Human morphology and temperature regulation
Andérson, G. S. (1999) · International Journal of Biometeorology · doi:10.1007/s004840050123 · Cited by 148
Performance of Personalized Ventilation in Conjunction with Mixing and Displacement Ventilation
Cermak, R., Melikov, A. K., Forejt, L., & Kovar, O. (2006) · Science and Technology for the Built Environment · doi:10.1080/10789669.2006.10391180 · Cited by 144
Air temperature thresholds for indoor comfort and perceived air quality
Zhang, H., Arens, E. A., & Pasut, W. (2011) · Building Research & Information · doi:10.1080/09613218.2011.552703 · Cited by 143
Considering individual physiological differences in a human thermal model
Zhang, H., Huizenga, C., Arens, E., & Yu, T. (2001) · Journal of Thermal Biology · doi:10.1016/s0306-4565(01)00051-1 · Cited by 140
Air movement preferences observed in office buildings
Zhang, H., Arens, E. A., Fard, S. A., Huizenga, C., Paliaga, G., Brager, G. S., & Zagreus, L. (2007) · International Journal of Biometeorology · doi:10.1007/s00484-006-0079-y · Cited by 136
Thermal comfort models for indoor spaces and vehicles—Current capabilities and future perspectives
Croitoru, C. V., Năstase, I., Bode, F. I., Meslem, A., & Dogeanu, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.105 · Cited by 136
Toftum, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00271.x · Cited by 136
Thermal comfort and older adults
van Hoof, J., & Hensen, J. J. (2006) · Gerontechnology · doi:10.4017/gt.2006.04.04.006.00 · Cited by 131
Human requirements in future air-conditioned environments
Fanger, P. O. (2001) · International Journal of Refrigeration · doi:10.1016/s0140-7007(00)00011-6 · Cited by 131
Field study of the impact of a desktop task/ambient conditioning system in office buildings
Bauman, F. S., Carter, T., & Baughman, A. (1998) · eScholarship (California Digital Library) · Cited by 129
Air movement and perceived air quality
Melikov, A. K., & Kaczmarczyk, J. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.06.017 · Cited by 125
Comparison of thermoregulatory responses between men and women immersed in cold water
Tikuisis, P., Jacobs, I. A., Moroz, D., Vallerand, A. L., & Martineau, L. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1403 · Cited by 124
Experimental study on a chair-based personalized ventilation system
Niu, J., Gao, N., Phoebe, M., & Zuo, H. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.10.011 · Cited by 123
Energy savings from extended air temperature setpoints and reductions in room air mixing
Hoyt, T., Lee, K. H., Zhang, H., et al. (2005) · eScholarship (California Digital Library) · Cited by 122
Melikov, A. K., Skwarczyński, M., Kaczmarczyk, J., & Zabecky, J. (2012) · Indoor Air · doi:10.1111/ina.12012 · Cited by 120
Energy savings from extended air temperature setpoints and reductions in room air mixing
Hoyt, T., Lee, K. H., Zhang, H., Arens, E. A., & Webster, T. (2005) · eScholarship (California Digital Library) · Cited by 120
The Acceptable Air Velocity Range for Local Air Movement in The Tropics
Gong, N., Tham, K. W., Melikov, A. K., Wyon, D. P., Sekhar, C., & Cheong, D. K. W. (2006) · Science and Technology for the Built Environment · doi:10.1080/10789669.2006.10391451 · Cited by 116
Design of an individually controlled system for an optimal thermal microenvironment
Watanabe, S., Melikov, A. K., & Knudsen, G. L. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.07.009 · Cited by 113
Yao, Y., Lian, Z., Liu, W., & Shen, Q. (2007) · Indoor and Built Environment · doi:10.1177/1420326x07084291 · Cited by 110
Human Response to Five Designs of Personalized Ventilation
Kaczmarczyk, J., Melikov, A. K., Bolashikov, Z. D., Nikolaev, L., & Fanger, P. O. (2006) · Science and Technology for the Built Environment · doi:10.1080/10789669.2006.10391184 · Cited by 108
Thermal sensation and comfort with different task conditioning systems
Amai, H., Tanabe, S., AKIMOTO, T., & Genma, T. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.07.043 · Cited by 107
Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality
Melikov, A. K., Ivanova, T. A., & Stefanova, G. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.07.013 · Cited by 101
Li, R., Sekhar, C., & Melikov, A. K. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.03.003 · Cited by 100
The influence of heated or cooled seats on the acceptable ambient temperature range
Zhang, Y. F., Wyon, D. P., Fang, L., & Melikov, A. K. (2007) · Ergonomics · doi:10.1080/00140130601154921 · Cited by 100
Ceiling mounted personalized ventilation system in hot and humid climate—An energy analysis
Yang, B., Sekhar, C., & Melikov, A. K. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.07.022 · Cited by 99
Thermal and moisture transport in fibrous materials
(2006) · CRC Press eBooks · doi:10.1201/9781439824351 · Cited by 99
Findings of Personalized Ventilation Studies in a Hot and Humid Climate
Sekhar, C., Gong, N., Tham, K. W., Cheong, D. K. W., Melikov, A. K., Wyon, D. P., & Fanger, P. O. (2005) · Science and Technology for the Built Environment · doi:10.1080/10789669.2005.10391157 · Cited by 94
Keyvanfar, A., Shafaghat, A., Majid, M. Z. A., Lamit, H., Hussin, M. W., Ali, K. N., & Saad, A. D. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.094 · Cited by 88
Energy-saving strategies with personalized ventilation in cold climates
Schiavon, S., & Melikov, A. K. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.11.018 · Cited by 84
Human Response to an Individually Controlled Microenvironment
Melikov, A. K., & Knudsen, G. M. (2007) · Science and Technology for the Built Environment · doi:10.1080/10789669.2007.10390977 · Cited by 84
Makhoul, A., Ghali, K., & Ghaddar, N. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.08.031 · Cited by 82
Temperature regulation and technology
Havenith, G. (2001) · Gerontechnology · doi:10.4017/gt.2001.01.01.004.00 · Cited by 82
Yang, B., Sekhar, C., & Melikov, A. K. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00655.x · Cited by 77
Thermal comfort and energy saving of a personalized PFCU air-conditioning system
Pan, C.-S., Chiang, H., Yen, M.-C., & Wang, C. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.08.006 · Cited by 69
Halvoňová, B., & Melikov, A. K. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.023 · Cited by 68
Chilled ceiling and displacement ventilation aided with personalized evaporative cooler
Chakroun, W. M., Ghaddar, N., & Ghali, K. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.08.026 · Cited by 66
Halvoňová, B., & Melikov, A. K. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.10.007 · Cited by 63
Foda, E., & Sirén, K. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.04.019 · Cited by 62
Makhoul, A., Ghali, K., & Ghaddar, N. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.11.016 · Cited by 58
Effect of warm air supplied facially on occupants’ comfort
Kaczmarczyk, J., Melikov, A. K., & Sliva, D. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.09.005 · Cited by 58
DeGroot, D. W., Havenith, G., & Kenney, W. L. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00717.2006 · Cited by 46
Sun, W., Cheong, D. K. W., & Melikov, A. K. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.04.004 · Cited by 43
Conceição, E. Z. E., Lúcio, M. M., Rosa, S. P., Custódio, A. L. V., Andrade, R. L., & Meira, M. J. P. A. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.07.020 · Cited by 41
Alternative personalized ventilation
Kalmár, F., & Kalmár, T. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.05.010 · Cited by 34
Chen, Y., Raphael, B., & Sekhar, C. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2012.710059 · Cited by 27
Halvoňová, B., & Melikov, A. K. (2010) · Science and Technology for the Built Environment · doi:10.1080/10789669.2010.10390893 · Cited by 23
Ghaddar, N., Ghali, K., & Chakroun, W. M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.02.010 · Cited by 20
Hoyt, T., Zhang, H. P. D., & Arens, E. A. (2009) · eScholarship (California Digital Library) · Cited by 20
Cited by
Sorted by citations
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Wearable thermoelectrics for personalized thermoregulation
Hong, S., Gu, Y., Seo, J. K., Wang, J., Liu, P., Meng, Y. S., Xu, S., & Chen, R. (2019) · Science Advances · doi:10.1126/sciadv.aaw0536 · Cited by 522
Kim, J., Zhou, Y., Schiavon, S., Raftery, P., & Brager, G. S. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.12.011 · Cited by 492
The human dimensions of energy use in buildings: A review
D’Oca, S., Hong, T., & Langevin, J. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.019 · Cited by 394
A review of thermal comfort models and indicators for indoor environments
Enescu, D. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.175 · Cited by 410
Metadata
- Authors
- Veselý, M., & Zeiler, W.
- Affiliations
- Eindhoven University of Technology (NL)
- Corresponding author
- Veselý, Michal
- ORCID
- Zeiler, Wim
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 34
- Pages
- 401-408
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2134642574
- Cited by
- 322
- References
- 80
- Citations by year
- 2026: 22 · 2025: 34 · 2024: 29 · 2023: 32 · 2022: 36 · 2021: 25 · 2020: 28 · 2019: 35 · 2018: 27 · 2017: 23 · 2016: 12 · 2015: 16 · 2014: 3
- FWCI
- 26.70
- Type
- journal article
- Language
- en
- Open access
- green
- research.tue.nl
- Licence
- Locations
- Renewable and Sustainable Energy Reviews (publishedVersion)
- TU/e Research Portal (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- TU/e Research Portal (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- thermal comfort, building energy performance, ventilation rate, energy consumption reduction, energy simulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review