Natural ventilation in warm climates: The challenges of thermal comfort, heatwave resilience and indoor air quality
Open accessAbstract
In buildings, energy is primarily consumed by mechanical air conditioning systems. Low energy alternatives, such as natural ventilation, are needed. However, they need to be able to cope with increasing heatwaves and pollution, particularly in warm climates. This review paper looked at the ability of natural ventilation to provide adequate thermal comfort, resilience against heatwaves, and good Indoor Air Quality in warm climates. Single-sided ventilation demonstrates the poorest ability to provide thermal comfort, while cross ventilation highlights better performance in terms of reducing indoor air temperatures compared to outdoor. However, windcatchers and solar chimneys displayed even better performance by producing relatively high ventilation rates. During heatwaves and future climatic scenarios, natural ventilation, by cross-ventilation, was not able to meet internal thermal comfort standards. A potential low energy solution could be combining solar chimneys or windcatchers with water evaporation cooling. A critical synthesis of the literature suggests that these systems can generate high ventilation rates and keep indoor temperatures around 8 °C cooler than outdoor temperatures in warm weather (>35 °C). However, no studies were found testing these systems against future climate scenarios, and further studies are recommended. The literature supported natural ventilation being effective in removing pollution generated indoors due to adequate ventilation rates. However, using unfiltered natural ventilation for areas with high outdoor pollution can increase the indoor deposition of harmful particulate matter. With increasing air pollution, further studies are urgently required to investigate filter enabled natural ventilation, particularly with solar chimney/windcatcher incorporated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55
de Dear, R. J., & Brager, G. S. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00005-1 · Cited by 1,438
Anthropogenic contribution to global occurrence of heavy-precipitation and high-temperature extremes
Fischer, E. M., & Knutti, R. (2015) · Nature Climate Change · doi:10.1038/nclimate2617 · Cited by 1,427
A theoretical adaptive model of thermal comfort – Adaptive Predicted Mean Vote (aPMV)
Yao, R., Li, B., & Liu, J. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.014 · Cited by 709
Urban air pollution in megacities of the world
Mage, D., Ozolins, G., Peterson, P., Webster, A., Orthofer, R., Vandeweerd, V., & Gwynne, M. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(95)00219-7 · Cited by 554
Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review
Chenari, B., Dias Carrilho, J., & Gameiro da Silva, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.074 · Cited by 515
Review of bioclimatic architecture strategies for achieving thermal comfort
Manzano-Agugliaro, F. R., Montoya, F. G., Sabio-Ortega, A., & García-Cruz, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.04.095 · Cited by 380
Energy saving potential of natural ventilation in China: The impact of ambient air pollution
Tong, Z., Chen, Y., Malkawi, A., Liu, Z., & Freeman, R. B. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.07.019 · Cited by 285
The development of commercial wind towers for natural ventilation: A review
Hughes, B. R., Calautit, J. K., & Ghani, S. A. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.11.066 · Cited by 278
Review of adaptive thermal comfort models in built environmental regulatory documents
Carlucci, S., Bai, L., de Dear, R., & Yang, L. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.053 · Cited by 275
Airflow assessment in cross-ventilated buildings with operable façade elements
Karava, P., Stathopoulos, T., & Athienitis, A. K. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.07.022 · Cited by 261
Air movement acceptability limits and thermal comfort in Brazil's hot humid climate zone
Cândido, C., de Dear, R. J., Lamberts, R., & Bittencourt, L. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.06.005 · Cited by 238
Jomehzadeh, F., Nejat, P., Calautit, J. K., Yusof, M. B. M., Zaki, S. A., Hughes, B. R., & Yazid, M. N. A. W. M. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.254 · Cited by 237
Tong, Z., Chen, Y., Malkawi, A., Adamkiewicz, G., & Spengler, J. D. (2016) · Environment International · doi:10.1016/j.envint.2016.01.016 · Cited by 222
Experimental study for natural ventilation on a solar chimney
Arce, J., Jiménez, M. J., Guzmán, J. D., Celemín, M. D. R. H., Álvarez, G., & Xamán, J. (2009) · Renewable Energy · doi:10.1016/j.renene.2009.04.026 · Cited by 202
Determining the influencing factors on the performance of solar chimney in buildings
Shi, L. X., Zhang, G., Yang, W. H., Huang, D., Cheng, X., & Setunge, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.02.033 · Cited by 183
Montazeri, H., & Montazeri, F. (2018) · Renewable Energy · doi:10.1016/j.renene.2017.11.032 · Cited by 175
9 out of 10 people worldwide breathe polluted air, but more countries are taking action
(2019) · Human Rights Documents Online · doi:10.1163/2210-7975_hrd-9841-20180002 · Cited by 173
Review of windcatcher technologies
Saadatian, O., Haw, L. C., Sopian, K., & Sulaiman, M. Y. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.11.037 · Cited by 169
Thailand ventilation comfort chart
Khedari, J., Yamtraipat, N., Pratintong, N., & Hirunlabh, J. (2000) · Energy and Buildings · doi:10.1016/s0378-7788(00)00050-5 · Cited by 167
A review of solar chimney integrated systems for space heating and cooling application
Monghasemi, N., & Vadiee, A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.06.078 · Cited by 167
Omrani, S., Garcia-Hansen, V., Capra, B. R., & Drogemuller, R. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.061 · Cited by 157
Dehghani-Sanij, A., Soltani, M., & Raahemifar, K. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.018 · Cited by 150
Architectural design of an advanced naturally ventilated building form
Lomas, K. J. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.05.004 · Cited by 147
Natural cooling of stand-alone houses using solar chimney and evaporative cooling cavity
Maerefat, M., & Poshtiri, A. H. (2010) · Renewable Energy · doi:10.1016/j.renene.2010.02.005 · Cited by 129
Lomas, K. J., & Ji, Y. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.01.001 · Cited by 127
Indoor temperature reduction by passive cooling systems
Givoni, B. (2009) · Solar Energy · doi:10.1016/j.solener.2009.10.003 · Cited by 126
Abdeen, A., Serageldin, A. A., Ibrahim, M. G. E., El-Zafarany, A. M., Ookawara, S. A., & MURATA, R. (2019) · Solar Energy · doi:10.1016/j.solener.2019.01.063 · Cited by 115
Kong, J. C., Niu, J., & Lei, C. (2020) · Solar Energy · doi:10.1016/j.solener.2020.01.017 · Cited by 103
Adapting dwellings for heat waves
Porritt, S. M., Shao, L., Cropper, P. C., & Goodier, C. I. (2011) · Sustainable Cities and Society · doi:10.1016/j.scs.2011.02.004 · Cited by 98
Performance analysis and improvement of the use of wind tower in hot dry climate
Bouchahm, Y., Bourbia, F., & Belhamri, A. (2010) · Renewable Energy · doi:10.1016/j.renene.2010.08.030 · Cited by 98
Heracleous, C., & Michael, A. (2018) · Energy · doi:10.1016/j.energy.2018.10.051 · Cited by 98
Influence of natural ventilation rate on indoor PM2.5 deposition
Liu, C., Yang, J., Ji, S., Lu, Y., Wu, P., & Chen, C. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.039 · Cited by 95
Short, C. A., Lomas, K. J., Giridharan, R., & Fair, A. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.02.031 · Cited by 91
Blocken, B. J. E., van Hooff, T., Aanen, L., & Bronsema, B. (2011) · Computers & Fluids · doi:10.1016/j.compfluid.2011.04.012 · Cited by 87
Impact of outdoor air quality on the natural ventilation usage of commercial buildings in the US
Chen, J., Brager, G. S., Augenbroe, G., & Song, X. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.11.020 · Cited by 86
CFD analysis of a heat transfer device integrated wind tower system for hot and dry climate
Calautit, J. K., Hughes, B. R., Chaudhry, H. N., & Ghani, S. A. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.01.021 · Cited by 85
Shi, L. X. (2018) · Energy · doi:10.1016/j.energy.2018.10.037 · Cited by 80
Pastore, L., Corrao, R., & Heiselberg, P. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.04.022 · Cited by 78
Impact of outdoor PM2.5 on natural ventilation usability in California’s nondomestic buildings
Martins, N. R., & da Graça, G. C. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.12.103 · Cited by 71
Calautit, J. K., O’Connor, D., & Hughes, B. R. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.024 · Cited by 70
Vargas-López, R., Xamán, J., Hernández–Pérez, I., Arce, J., Zavala-Guillén, I., Jiménez, M. J., & Celemín, M. D. R. H. (2018) · Energy · doi:10.1016/j.energy.2018.12.148 · Cited by 67
Kyritsi, E., & Michael, A. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106384 · Cited by 67
Jamaludin, A. A., Hussein, H., Ariffin, A. R. M., & Keumala, N. I. M. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2013.12.050 · Cited by 63
Calautit, J. K., Hughes, B. R., & Ghani, S. A. (2012) · Architectural Science Review · doi:10.1080/00038628.2012.686433 · Cited by 59
Numerical study of vertical solar chimneys with moist air in a hot and humid climate
Sudprasert, S., Chinsorranant, C., & Rattanadecho, P. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.06.054 · Cited by 59
Yusoff, W. F. M., Salleh, E., Adam, N. M., Sapian, A. R., & Sulaiman, M. Y. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.04.018 · Cited by 56
Poshtiri, A. H., Pakdel, S. H., & Jafari, A. (2016) · Energy · doi:10.1016/j.energy.2016.02.033 · Cited by 48
Abdallah, A. S. H., Yoshino, H., Tomonobu, G. O. T. O., Enteria, N. A., Radwan, M. M., & Eid, M. (2013) · International journal of energy and environmental engineering · doi:10.1186/2251-6832-4-45 · Cited by 43
Experimental investigation of a modular wind tower in hot and dry regions
Khani, S. M. R., Bahadori, M. N., & Dehghani-Sanij, A. (2017) · Energy Sustainable Development/Energy for sustainable development · doi:10.1016/j.esd.2017.03.003 · Cited by 35
Yu, R., Zhai, P., & Chen, Y. (2018) · Current Opinion in Environmental Sustainability · doi:10.1016/j.cosust.2018.03.008 · Cited by 33
A methodology to evaluate the indoor natural ventilation in hot climates: Heat Balance Index
Castillo, J. A., & Huelsz, G. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.12.027 · Cited by 32
Priya, R. S., Sundarraja, M. C., & Radhakrishnan, S. (2012) · Energy Efficiency · doi:10.1007/s12053-012-9155-9 · Cited by 31
Will naturally ventilated dwellings remain safe during heatwaves?
Alessandrini, J.-M., Ribéron, J., & Da Silva, D. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.10.033 · Cited by 31
Challenges in the low-carbon adaptation of China’s apartment towers
Short, C. A., Song, J., Mottet, L., Chen, S., Wu, J., & Ge, J. (2018) · Building Research & Information · doi:10.1080/09613218.2018.1489465 · Cited by 30
Self-citationMcCabe, C., & Roaf, S. (2012) · Architectural Science Review · doi:10.1080/00038628.2012.723398 · Cited by 28
Kim, J., Kong, M., Hong, T., Jeong, K., & Lee, M. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.12.054 · Cited by 27
Modelling natural ventilation for summer thermal comfort in Mediterranean dwellings
Spentzou, E., Cook, M., & Emmitt, S. (2017) · International Journal of Ventilation · doi:10.1080/14733315.2017.1302658 · Cited by 26
Oar, Oria, & Ied (2014) · Cited by 11
Adaptation of Australian houses and households to future heat waves
Palmer, J., Bennetts, H., Pullen, S., Zuo, J., Ma, T., & Chileshe, N. (2014) · Adelaide Research & Scholarship (AR&S) (University of Adelaide) · Cited by 8
Lun, I. Y.-F., Ohba, M., & Morikami, S. (2012) · International Journal of Ventilation · doi:10.1080/14733315.2012.11683990 · Cited by 5
Metadata
- Authors
- Ahmed, T., Kumar, P., & Mottet, L.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 138
- Pages
- 110669
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W3113818246
- Cited by
- 270
- References
- 63
- FWCI
- 12.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.