CoChat

SuperCam calibration targets on board the perseverance rover: Fabrication and quantitative characterization

Open access
Cousin, A., Sautter, V., Fabre, C., Dromart, G., Montagnac, G., Drouet, C., Meslin, P.Y., Gasnault, O., Beyssac, O., Bernard, S., Cloutis, E., Forni, O., Beck, P., Fouchet, T., Johnson, J.R., Lasue, J., Ollila, A.M., De Parseval, P., Gouy, S., Caron, B., Madariaga, J.M., Arana, G., Madsen, M. Bo, Laserna, J., Moros, J., Manrique, J.A., Lopez-Reyes, G., Rull, F., Maurice, S., Wiens, R.C. · 2022 · Spectrochimica Acta Part B: Atomic Spectroscopy
Cited by 47

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

The Perseverance rover is exploring Jezero crater on Mars since February 2021. SuperCam instrument is part of the scientific payload, combining five different techniques in order to characterize the targets to sample: LIBS (Laser-Induced Breakdown Spectroscopy), Raman and Visible and Infrared (VISIR) spectroscopies, Sound Recording and a colored Imager. Thirty-six calibration targets have been developed for this instrument. Twenty-three of these calibration targets are dedicated to the LIBS technique, corresponding to rocks and/or minerals. Raman and VISIR spectroscopy have their own calibration targets but may also use the LIBS mineral targets as reference on Mars to test mineral detections. The choice and the fabrication of these calibration targets have been made in order to fulfill the science intents of the mission, as well as the technical and science intents of each of the SuperCam technique. These calibration targets have been spectrally characterized and they have shown to be chemically homogeneous at the SuperCam LIBS scale. Their elementary compositions are given, using two different quantitative methods. The composition of the calibration targets will be used as reference for future assessment of the quantitative capability of the SuperCam LIBS technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sab.2021.106341

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 47

Metadata

Authors
Cousin, A., Sautter, V., Fabre, C., Dromart, G., Montagnac, G., Drouet, C., Meslin, P. Y., Gasnault, O., Beyssac, O., Bernard, S., Cloutis, E., Forni, O., Beck, P., Fouchet, T., Johnson, J. R., Lasue, J., Ollila, A. M., De Parseval, P., Gouy, S., Caron, B., Madariaga, J. M., Arana, G., Madsen, M. B., Laserna, J., Moros, J., Manrique, J. A., Lopez-Reyes, G., Rull, F., Maurice, S., & Wiens, R. C.
Venue
Spectrochimica Acta Part B: Atomic Spectroscopy
Publisher
Elsevier BV
Published
2022-02
Volume
188
Pages
106341
ISSN
0584-8547 (ISSN-L)
OpenAlex
W4200498533
Cited by
47
References
12
FWCI
4.36
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SuperCam calibration targets on board the perseverance rover: Fabrication and quantitative characterization. https://app.cochat.ai/papers/10.1016/j.sab.2021.106341
The paper
Cousin, A., Sautter, V., Fabre, C., Dromart, G., Montagnac, G., Drouet, C., Meslin, P. Y., Gasnault, O., Beyssac, O., Bernard, S., Cloutis, E., Forni, O., Beck, P., Fouchet, T., Johnson, J. R., Lasue, J., Ollila, A. M., De Parseval, P., Gouy, S., . . . Wiens, R. C. (2022). SuperCam calibration targets on board the perseverance rover: Fabrication and quantitative characterization. Spectrochimica Acta Part B: Atomic Spectroscopy. https://doi.org/10.1016/j.sab.2021.106341

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.