The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Artificial intelligence for breast cancer detection in mammography and digital breast tomosynthesis: State of the art
Open accessAbstract
Screening for breast cancer with mammography has been introduced in various countries over the last 30 years, initially using analog screen-film-based systems and, over the last 20 years, transitioning to the use of fully digital systems. With the introduction of digitization, the computer interpretation of images has been a subject of intense interest, resulting in the introduction of computer-aided detection (CADe) and diagnosis (CADx) algorithms in the early 2000's. Although they were introduced with high expectations, the potential improvement in the clinical realm failed to materialize, mostly due to the high number of false positive marks per analyzed image. In the last five years, the artificial intelligence (AI) revolution in computing, driven mostly by deep learning and convolutional neural networks, has also pervaded the field of automated breast cancer detection in digital mammography and digital breast tomosynthesis. Research in this area first involved comparison of its capabilities to that of conventional CADe/CADx methods, which quickly demonstrated the potential of this new technology. In the last couple of years, more mature and some commercial products have been developed, and studies of their performance compared to that of experienced breast radiologists are showing that these algorithms are on par with human-performance levels in retrospective data sets. Although additional studies, especially prospective evaluations performed in the real screening environment, are needed, it is becoming clear that AI will have an important role in the future breast cancer screening realm. Exactly how this new player will shape this field remains to be determined, but recent studies are already evaluating different options for implementation of this technology. The aim of this review is to provide an overview of the basic concepts and developments in the field AI for breast cancer detection in digital mammography and digital breast tomosynthesis. The pitfalls of conventional methods, and how these are, for the most part, avoided by this new technology, will be discussed. Importantly, studies that have evaluated the current capabilities of AI and proposals for how these capabilities should be leveraged in the clinical realm will be reviewed, while the questions that need to be answered before this vision becomes a reality are posed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21492 · Cited by 84,109
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Shin, H.-C., Roth, H. R., Gao, M., Lu, L., Xu, Z., Nogues, I., Yao, J., Mollura, D., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528162 · Cited by 5,759
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
(2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-67558-9 · Cited by 1,117
Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., et al. (2013) · Radiology · doi:10.1148/radiol.12121373 · Cited by 1,012
Large scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965
Self-citationCiatto, S., Houssami, N., Bernardi, D., Caumo, F., Pellegrini, M., Brunelli, S., Tuttobene, P., Bricolo, P., Fantò, C., Valentini, M., et al. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70134-7 · Cited by 838
Digital tomosynthesis in breast imaging.
Niklason, L. T., Christian, B. T., Niklason, L. E., Kopans, D. B., Castleberry, D. E., Opsahl-Ong, B. H., Landberg, C. E., Slanetz, P. J., Giardino, A. A., Moore, R., et al. (1997) · Radiology · doi:10.1148/radiology.205.2.9356620 · Cited by 763
A Deep Learning Mammography-based Model for Improved Breast Cancer Risk Prediction
Yala, A., Lehman, C., Schuster, T., Portnoi, T., & Barzilay, R. (2019) · Radiology · doi:10.1148/radiol.2019182716 · Cited by 758
Freer, T. W., & Ulissey, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001282 · Cited by 751
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Self-citationDiagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Self-citationPotential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
Warren Burhenne, L. J., Wood, S. A., D'Orsi, C. J., Feig, S. A., Kopans, D. B., O'Shaughnessy, K. F., Sickles, E. A., Tabar, L., Vyborny, C. J., & Castellino, R. A. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma15554 · Cited by 554
Huynh, B. Q., Li, H., & Giger, M. L. (2016) · Journal of Medical Imaging · doi:10.1117/1.jmi.3.3.034501 · Cited by 539
Kim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525
Extracellular Total Electrolyte Concentration Imaging for Electrical Brain Stimulation (EBS)
Sajib, S. Z. K., Lee, M. B., Kim, H. J., Woo, E. J., & Kwon, O. I. (2018) · Scientific Reports · doi:10.1038/s41598-017-18515-3 · Cited by 491
Al-masni, M. A., Al-antari, M. A., Park, J.-M., Gi, G., Kim, T.-Y., Rivera, P., Valarezo, E., Choi, M.-T., Han, S.-M., & Kim, T.-S. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.01.017 · Cited by 482
Birdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428
Schaffter, T., Buist, D. S. M., Lee, C. I., Nikulin, Y., Ribli, D., Guan, Y., Lotter, W., Jie, Z., Du, H., Wang, S., et al. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.0265 · Cited by 409
Becker, A. S., Marcon, M., Ghafoor, S., Wurnig, M. C., Frauenfelder, T., & Boss, A. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000358 · Cited by 352
Samala, R. K., Chan, H., Hadjiiski, L., Helvie, M. A., Wei, J., & Cha, K. (2016) · Medical Physics · doi:10.1118/1.4967345 · Cited by 289
Satisfaction of Search in Diagnostic Radiology
BERBAUM, K. S., FRANKEN, E. A., DORFMAN, D. D., ROOHOLAMINI, S. A., KATHOL, M. H., BARLOON, T. J., BEHLKE, F. M., SATO, Y., LU, C. H., EL-KHOURY, G. Y., et al. (1990) · Investigative Radiology · doi:10.1097/00004424-199002000-00006 · Cited by 285
Computer aided detection (CAD): an overview
Castellino, R. A. (2005) · Cancer Imaging · doi:10.1102/1470-7330.2005.0018 · Cited by 284
Bernardi, D., Macaskill, P., Pellegrini, M., Valentini, M., Fantò, C., Ostillio, L., Tuttobene, P., Luparia, A., & Houssami, N. (2016) · The Lancet Oncology · doi:10.1016/s1470-2045(16)30101-2 · Cited by 275
Deep learning in mammography and breast histology, an overview and future trends
Hamidinekoo, A., Denton, E., Rampun, A., Honnor, K., & Zwiggelaar, R. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.03.006 · Cited by 273
Computer-Aided Breast Cancer Detection Using Mammograms: A Review
Ganesan, K., Acharya, U. R., Chua, C. K., Min, L. C., Abraham, K. T., & Ng, K.-H. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2232289 · Cited by 253
Conant, E. F., Toledano, A. Y., Periaswamy, S., Fotin, S. V., Go, J., Boatsman, J. E., & Hoffmeister, J. W. (2019) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2019180096 · Cited by 241
Skaane, P., & Skjennald, A. (2004) · Radiology · doi:10.1148/radiol.2321031624 · Cited by 236
Samala, R. K., Chan, H.-P., Hadjiiski, L. M., Helvie, M. A., Cha, K. H., & Richter, C. D. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa93d4 · Cited by 232
Skaane, P., Young, K., & Skjennald, A. (2003) · Radiology · doi:10.1148/radiol.2293021171 · Cited by 221
A Deep Learning Model to Triage Screening Mammograms: A Simulation Study
Yala, A., Schuster, T., Miles, R., Barzilay, R., & Lehman, C. (2019) · Radiology · doi:10.1148/radiol.2019182908 · Cited by 210
Gur, D., Bandos, A. I., Cohen, C. S., Hakim, C. M., Hardesty, L. A., Ganott, M. A., Perrin, R. L., Poller, W. R., Shah, R., Sumkin, J. H., et al. (2008) · Radiology · doi:10.1148/radiol.2491072025 · Cited by 186
Gilbert, F. J., Tucker, L., Gillan, M. G. C., Willsher, P., Cooke, J., Duncan, K. A., Michell, M. J., Dobson, H. M., Lim, Y. Y., Suaris, T., et al. (2015) · Radiology · doi:10.1148/radiol.2015142566 · Cited by 178
Dembrower, K., Liu, Y., Azizpour, H., Eklund, M., Smith, K., Lindholm, P., & Strand, F. (2020) · Radiology · doi:10.1148/radiol.2019190872 · Cited by 163
A Multi-scale CNN and Curriculum Learning Strategy for Mammogram Classification
Lotter, W. E., Sorensen, G., & Cox, D. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67558-9_20 · Cited by 159
Deep Learning to Distinguish Recalled but Benign Mammography Images in Breast Cancer Screening
Aboutalib, S., Mohamed, A. A., Berg, W. A., Zuley, M. L., Sumkin, J. H., & Wu, S. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-1115 · Cited by 149
Skaane, P. (2008) · Acta Radiologica · doi:10.1080/02841850802563269 · Cited by 144
Hofvind, S. S. H., Hovda, T., Holen, Å. S., Lee, C. I., Albertsen, J., Bjørndal, H., Brandal, S. H. B., Gullien, R., Lømo, J., Park, D., et al. (2018) · Radiology · doi:10.1148/radiol.2018171361 · Cited by 135
Destounis, S. V., DiNitto, P. A., Logan-Young, W. W., Bonaccio, E., Zuley, M. L., & Willison, K. M. (2004) · Radiology · doi:10.1148/radiol.2322030034 · Cited by 124
Applying Data-driven Imaging Biomarker in Mammography for Breast Cancer Screening: Preliminary Study
Kim, E., Kim, H.-E., Han, K., Kang, B. J., Sohn, Y., Woo, O. H., & Lee, C. W. (2018) · Scientific Reports · doi:10.1038/s41598-018-21215-1 · Cited by 123
Mendel, K. R., Li, H., Sheth, D., & Giger, M. L. (2018) · Academic Radiology · doi:10.1016/j.acra.2018.06.019 · Cited by 116
Samala, R. K., Chan, H., Hadjiiski, L. M., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aabb5b · Cited by 104
Classification of Whole Mammogram and Tomosynthesis Images Using Deep Convolutional Neural Networks
Zhang, X., Zhang, Y., Han, E. Y., Jacobs, N., Han, Q., Wang, X.-Q., & Liu, J. (2018) · IEEE Transactions on Nanobioscience · doi:10.1109/tnb.2018.2845103 · Cited by 102
European Breast Cancer Service Screening Outcomes: A First Balance Sheet of the Benefits and Harms
Paci, E., Broeders, M. J. M., Hofvind, S. S. H., Puliti, D., Duffy, S. W., & the EUROSCREEN Working Group (2014) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-13-0320 · Cited by 96
Importance of Comparison of Current and Prior Mammograms in Breast Cancer Screening
Roelofs, A. A. J., Karssemeijer, N., Wedekind, N., Beck, C., van Woudenberg, S., Snoeren, P. R., Hendriks, J. H. C. L., Turco, M. R. D., Bjurstam, N., Junkermann, H., et al. (2007) · Radiology · doi:10.1148/radiol.2421050684 · Cited by 93
A review of computer aided detection in mammography
Katzen, J. T., & Dodelzon, K. (2018) · Clinical Imaging · doi:10.1016/j.clinimag.2018.08.014 · Cited by 83
Samala, R. K., Chan, H., Hadjiiski, L. M., Kenny, H., & Helvie, M. A. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2217092 · Cited by 74
Ikeda, D. M., Birdwell, R. L., O′Shaughnessy, K. F., Sickles, E. A., & Brenner, R. J. (2004) · Radiology · doi:10.1148/radiol.2303030254 · Cited by 73
Benedikt, R. A., Boatsman, J. E., Swann, C. A., Kirkpatrick, A. D., & Toledano, A. Y. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.17.18185 · Cited by 70
Combining two mammographic projections in a computer aided mass detection method
van Engeland, S., & Karssemeijer, N. (2007) · Medical Physics · doi:10.1118/1.2436974 · Cited by 63
Kooi, T., & Karssemeijer, N. (2017) · Journal of medical imaging · doi:10.1117/1.jmi.4.4.044501 · Cited by 62
Arieno, A. L., Chan, A. H. L., & Destounis, S. V. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.18.20391 · Cited by 59
Use of prior mammograms in the classification of benign and malignant masses
Varela, C., Karssemeijer, N., Hendriks, J. H. C. L., & Holland, R. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.04.007 · Cited by 54
Missed fractures resulting from satisfaction of search effect
Berbaum, K. S., El-Khoury, G. Y., Franken, E. A., et al. (1994) · Emergency Radiology · doi:10.1007/bf02614935 · Cited by 52
Fotin, S. V., Yin, Y., Haldankar, H., Hoffmeister, J. W., & Periaswamy, S. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2217045 · Cited by 43
Kim, D. H., Kim, S. T., & Ro, Y. M. (2016) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2016.7471811 · Cited by 42
Posso, M., Puig, T., Carles-Lavila, M., Rué, M., Canelo‐Aybar, C., & Bonfill, X. (2017) · European Journal of Radiology · doi:10.1016/j.ejrad.2017.09.013 · Cited by 42
Artificial intelligence and breast screening: French Radiology Community position paper
Thomassin‐Naggara, I., Balleyguier, C., Ceugnart, L., Heid, P., Lenczner, G., Maire, A., Séradour, B., Verzaux, L., & Taourel, P. (2019) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2019.08.005 · Cited by 38
Multi-criterion mammographic risk analysis supported with multi-label fuzzy-rough feature selection
Qu, Y., Yue, G., Shang, C., Yang, L., Reyer Zwiggelaar, A., & Shen, Q. (2019) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2019.101722 · Cited by 30
Chae, E. Y., Kim, H. H., Jeong, J.-W., et al. (2018) · European Radiology · doi:10.1007/s00330-018-5886-0 · Cited by 29
Wang, X., Li, L., Xu, W., Liu, W., Lederman, D., & Zheng, B. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.10.026 · Cited by 20
Use of convolutional neural networks to predict risk of masking by mammographic density
Mainprize, J. G., Martel, A. L., Alonzo‐Proulx, O., Cleland, T., Yaffe, M. J., Jong, R. A., & Harvey, J. A. (2019) · SPIE Medical Imaging: Computer-Aided Diagnosis · doi:10.1117/12.2513063 · Cited by 17
Samala, R. K., Chan, H., Hadjiiski, L. M., & Helvie, M. A. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/19/7092 · Cited by 16
Deep learning of symmetrical discrepancies for computer-aided detection of mammographic masses
Kooi, T., & Karssemeijer, N. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2254586 · Cited by 4
Cited by
Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00298-x · Cited by 598
Wang, Y., Liu, C., Hu, W., Luo, L., Shi, D., Zhang, J., Yin, Q., Zhang, L., Han, X., & He, M. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01032-9 · Cited by 76
Li, J., Li, L., You, P., Wei, Y., & Xu, B. (2023) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2023.02.009 · Cited by 55
Artificial intelligence in senology—where do we stand and what are the future horizons?
Mundinger, A., & Mundinger, C. (2024) · European Journal of Breast Health · doi:10.4274/ejbh.galenos.2024.2023-12-13 · Cited by 9
Metadata
- Authors
- Sechopoulos, I., Teuwen, J., & Mann, R.
- Venue
- Seminars in Cancer Biology
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 72
- Pages
- 214-225
- ISSN
- 1044-579X (ISSN-L)
- OpenAlex
- W3035655244
- Cited by
- 341
- References
- 70
- FWCI
- 13.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.