Devices for home detection of obstructive sleep apnea: A review
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
One of the most common sleep-related disorders is obstructive sleep apnea, characterized by a reduction of airflow while breathing during sleep and cause significant health problems. This disorder is mainly diagnosed in sleep labs with polysomnography, involving high costs and stress for the patient. To address this situation multiple systems have been proposed to conduct the examination and analysis in the patient's home, using sensors to detect physiological signals that are examined by algorithms. The objective of this research is to review publications that show the performance of different devices for ambulatory diagnosis of sleep apnea. Commercial systems that were examined by an independent research group and validated research projects were selected. In total 117 articles were analysed, including a total of 50 commercial devices. Each article was evaluated according to diagnostic elements, level of automatisation implemented and the deducted level of evidence and quality rating. Each device was categorized using the SCOPER categorization system, including an additional proposed category, and a final comparison was performed to determine the sensors that provided the best results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increased Prevalence of Sleep-Disordered Breathing in Adults
Peppard, P. E., Young, T., Barnet, J. H., Palta, M., Hagen, E. W., & Hla, K. M. (2013) · American Journal of Epidemiology · doi:10.1093/aje/kws342 · Cited by 4,618
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Apnea medassist: Real-time sleep apnea monitor using single-lead ECG
Bsoul, M., Minn, H., & Tamil, L. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2087386 · Cited by 297
Pittman, S. D., Ayas, N. T., MacDonald, M. M., Malhotra, A., Fogel, R. B., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.5.923 · Cited by 175
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
Validation of a Portable Monitoring System for the Diagnosis of Obstructive Sleep Apnea Syndrome
Santos-Silva, R., Sartori, D. E., Truksinas, V., Truksinas, E., Alonso, F. F. F. D., Tufik, S., & Bittencourt, L. R. A. (2009) · Sleep · doi:10.1093/sleep/32.5.629 · Cited by 142
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
Validation of a Self-Applied Unattended Monitor for Sleep Disordered Breathing
Ayappa, I., Norman, R. G., Seelall, V., & Rapoport, D. M. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27075 · Cited by 125
Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor
Nam, Y., Kim, Y., & Lee, J. (2016) · Sensors · doi:10.3390/s16050750 · Cited by 124
Cited by
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
A Systematic Review of Detecting Sleep Apnea Using Deep Learning
Mostafa, S. S., Mendonça, F., G. Ravelo-García, A., & Morgado-Dias, F. (2019) · Sensors · doi:10.3390/s19224934 · Cited by 182
“…reviews have been performed in the field of sleep apnea detection, such as analyzing devices for home detection of obstructive sleep apnea (OSA) [26], classification methods based on respiratory and oximetry signals [26], di ff erent detection approaches [27], detection and treatment methods [28].”
MethodSelf-citationO’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“Application of computer-assisted quantification of the time, number and severity of desaturations aids detection of OSA (39,41).”
Getting More from the Sleep Recording
McNicholas, W. T. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.001 · Cited by 3
Metadata
- Authors
- Mendonça, F., Mostafa, S. S., Ravelo-García, A. G., Morgado-Dias, F., & Penzel, T.
- Venue
- Sleep Medicine Reviews
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 41
- Pages
- 149-160
- ISSN
- 1087-0792 (ISSN-L)
- OpenAlex
- W2788681332
- Cited by
- 126
- References
- 22
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Devices for home detection of obstructive sleep apnea: A review. https://app.cochat.ai/papers/10.1016/j.smrv.2018.02.004
- The paper
- Mendonça, F., Mostafa, S. S., Ravelo-García, A. G., Morgado-Dias, F., & Penzel, T. (2018). Devices for home detection of obstructive sleep apnea: A review. Sleep Medicine Reviews. https://doi.org/10.1016/j.smrv.2018.02.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).