First human trials of a dry electrophysiology sensor using a carbon nanotube array interface
Open accessThe DOI matches its Crossref record.
Abstract
We report the results from the first human trials of a new dry electrode sensor for surface biopotential applications. This sensor uses nanotechnology to improve performance and wearability. Standard electrodes for demanding applications such as EEG require skin preparation and/or the use of electrolytic substances to provide and effective electrical interface. The contact surface of the electrode described here is covered with an array of carbon nanotubes designed for penetration of the outer layers of the skin for improved electrical contact without the use of electrolytic gel. In previous papers we detailed the design concept and reported the results of the initial tests of a first prototype—immersion in saline solution and signal detection in animal skin. In this paper we describe the first human trials of the prototype, which indicate performance on par with state-of-the-art research-oriented wet electrodes. No side effects have been observed 6 months after the tests, and the subject did not report any pain or unusual sensations upon application of the electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 828
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Nanomaterial‐Enabled Stretchable Conductors: Strategies, Materials and Devices
Yao, S., & Zhu, Y. (2015) · Advanced Materials · doi:10.1002/adma.201404446 · Cited by 695
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Lopez-Gordo, M., Sanchez-Morillo, D., & Valle, F. (2014) · Sensors · doi:10.3390/s140712847 · Cited by 410
Wearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Progress of new label-free techniques for biosensors: a review
Sang, S., Wang, Y., Feng, Q., Wei, Y., Ji, J., & Zhang, W. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.991270 · Cited by 272
Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Chen, Y.-H., De Beeck, M., Vanderheyden, L., Carrette, E., Mihajlović, V., Vanstreels, K., Grundlehner, B., Gadeyne, S., Boon, P., & Van Hoof, C. (2014) · Sensors · doi:10.3390/s141223758 · Cited by 238
Imaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 166
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Metadata
- Authors
- Ruffini, G., Dunne, S., Fuentemilla, L., Grau, C., Farrés, E., Marco-Pallarés, J., Watts, P. C. P., & Silva, S. R. P.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2008-06
- Volume
- 144
- Issue
- 2
- Pages
- 275-279
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2006039835
- Cited by
- 113
- References
- 0
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.