The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Abstract
A conventional clinical biopotential measurement system requires the use of wet electrodes that are in contact with skin using conductive gel. Those systems can acquire high-quality signals but may not be feasible for a long-term purpose due to the skin irritation and allergic contact dermatitis. The emerging of human-centered monitoring calls for alternative solutions. Recent technological advances enable capacitive measurement of electrophysiological measurement, which can acquire signals through cloth or even with an air gap; however, difficulties still exist. This paper systemically reviews the recent progress in capacitive measurement from electrode design, analog front end to high-level system architecture, aiming to provide comprehensive and practical instructions for entire system design. The current development serves as the solid fundamental, raising new solutions for future improvement. In addition, the challenges and the strategies are highlighted in order to demonstrate a technical guide. Some perspectives based on our experience are also discussed hoping to inspire new idea and technique in this area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Wireless body sensor networks for health-monitoring applications
Hao, Y., & Foster, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/11/r01 · Cited by 404
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
Capacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248
Cited by
Flexible Carbon Nanotube-Based Polymer Electrode for Long-Term Electrocardiographic Recording
Chi, M., Zhao, J., Dong, Y., & Wang, X. (2019) · Materials · doi:10.3390/ma12060971 · Cited by 68
Metadata
- Authors
- Sun, Y., & Yu, X. B.
- Venue
- IEEE Sensors Journal
- Published
- 2016-05
- Volume
- 16
- Issue
- 9
- Pages
- 2832-2853
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2332845049
- Cited by
- 174
- References
- 9
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review. https://app.cochat.ai/papers/10.1109/jsen.2016.2519392
- The paper
- Sun, Y., & Yu, X. B. (2016). Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2016.2519392
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.