Wearable potentiometric tattoo biosensor for on-body detection of G-type nerve agents simulants
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A new wearable potentiometric tattoo biosensor for real-time on-body monitoring of G-type nerve agents simulant is described. The skin-worn flexible biosensor responds rapidly and selectively to the fluorine-containing organophosphates (OP) nerve agent simulant diisopropyl fluorophosphate (DFP, a model OP analyte) in both liquid and vapor phases. The epidermal potentiometric OP biosensor relies on the pH-sensitive polyaniline (PANi) coating on a flexible printed transducer for monitoring the proton release during the enzymatic hydrolysis of DFP by enzyme organophosphate hydrolase (OPH). The sensing electrodes are screen printed on a temporary tattoo paper and are interfaced to a conformal electronic interface that provides wireless data transmission. The skin-worn OP potentiometric sensor can withstand severe mechanical strains without compromising its analytical performance. The biosensor displays a wide dynamic range, fast response and high selectivity towards DFP (including efficient discrimination against organophosphate pesticides), and good reproducibility. The attractive performance of the new wearable biosensor indicates considerable promise for on-body threat detection towards rapid warning regarding potential exposure to G-series nerve agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kamoun, E. A., Kenawy, E.-R. S., & Chen, X. (2017) · Journal of Advanced Research · doi:10.1016/j.jare.2017.01.005 · Cited by 1,707
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationTattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Self-citation
Cited by
Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope
Singh, A., Sharma, A., Ahmed, A., Sundramoorthy, A. K., Furukawa, H., Arya, S., & Khosla, A. (2021) · Biosensors · doi:10.3390/bios11090336 · Cited by 579
Flexible Hybrid Sensors for Health Monitoring: Materials and Mechanisms to Render Wearability
Gao, Y., Yu, L., Yeo, J. C., & Lim, C. T. (2020) · Advanced Materials · doi:10.1002/adma.201902133 · Cited by 505
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Wearable Bioelectronics: Enzyme-Based Body-Worn Electronic Devices
Kim, J., Jeerapan, I., Sempionatto, J. R., Barfidokht, A., Mishra, R. K., Campbell, A. S., Hubble, L. J., & Wang, J. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00451 · Cited by 289
Self-citationRecent advances and perspectives in sweat based wearable electrochemical sensors
Mohan, A. M. V., Rajendran, V., Mishra, R. K., & Jayaraman, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116024 · Cited by 231
Self-citationWearable Chemical Sensors: Emerging Systems for On-Body Analytical Chemistry
Sempionatto, J. R., Jeerapan, I., Krishnan, S., & Wang, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04668 · Cited by 229
Self-citationRecent Advancements in Development of Wearable Gas Sensors
Bag, A., & Lee, N. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000883 · Cited by 214
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Mamun, M. A. A., & Yuce, M. R. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202005703 · Cited by 201
Wearable electrochemical sensors for forensic and clinical applications
Ferreira, P. C., Ataíde, V. N., Silva Chagas, C. L., Angnes, L., Tomazelli Coltro, W. K., Longo Cesar Paixão, T. R., & Reis de Araujo, W. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115622 · Cited by 170
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64
Point-of-use robotic sensors for simultaneous pressure detection and chemical analysis
Amit, M., Mishra, R. K., Hoang, Q., Galan, A. M., Wang, J., & Ng, T. N. (2019) · Materials Horizons · doi:10.1039/c8mh01412d · Cited by 57
Self-citation
Metadata
- Authors
- Mishra, R. K., Barfidokht, A., Karajic, A., Sempionatto, J. R., Wang, J., & Wang, J.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 273
- Pages
- 966-972
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2810109876
- Cited by
- 128
- References
- 4
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.