PEDOT: PSS coating on gold microelectrodes with excellent stability and high charge injection capacity for chronic neural interfaces
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Abstract PEDOT: PSS has become one of the best choices as coating material of neural interfaces electrodes for its excellent biocompatibility, chemical steadiness and extremely inhomogeneous topography that facilitate reversible faradaic charge injection. However, chronic application of this material is still a matter of challenge for its poor adhesion to metallic electrodes. This study presents two new methods that increases stability and stimulation capacity of PEDOT: PSS (poly(3,4-ethylenedioxythiophene): poly(styrene sulfonate)) coated neural interfaces electrodes. These improvements in the characteristics make PEDOT: PSS as a promising coating material for the long-term stable bidirectional neural application. The first process ensures long-term stability of PEDOT: PSS coating. The stability improvement is done by creating a rough and porous surface with selective iodine etching of Au electrodes. The pores act as anchors and increases mechanical bonding between PEDOT: PSS coating and electrode surface, hence the stability of the coating increases. PEDOT: PSS coating on iodine etched gold electrode showed 100% stability under strong ultrasonic stability test compared to non-etched electrodes. Long-term in vitro continuous stimulation for 7 days was performed to evaluate the stability of the coating. 1 μm thick PEDOT:PSS coating on iodine etched Au electrode completely survived under 604 million continuous current pulses that was evaluated by SEM image and electrochemical impedance spectroscopy (EIS). The second process improves the characteristics of PEDOT: PSS coated electrodes in terms of stimulation capacity. This is done by electrochemical modification of PEDOT: PSS coating surface by applying a cyclic voltammetry method. A perfect and effective method is developed by comparative analysis and optimizing the parameters of cyclic voltammetry. The PEDOT: PSS coating presented here (1 μm thick) reduces the impedance of bare Au electrode by around 99%. This electrochemical modification method further reduces the impedance of this PEDOT: PSS coated electrode by 33%. Moreover, this method reduces electrode polarization under stimulation by 30.5%. Reduced electrode impedance and polarization under stimulation are beneficial for increasing safe charge injection limit of the electrode for stimulation. Both processes facilitate the use of PEDOT: PSS coating as a true long-term stable and promising material on gold microelectrodes of neural interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
Noninvasive brain stimulation in traumatic brain injury
Demirtas-Tatlidede, A., Vahabzadeh-Hagh, A. M., Bernabeu, M., Tormos, J. M., & Pascual-Leone, A. (2012) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0b013e318217df55 · Cited by 149
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Gulino, M., Kim, D., Pané, S., Santos, S. D., & Pêgo, A. P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00689 · Cited by 159
“Carbon nanotubes (Jiang et al., 2011; Schmidt et al., 2013) and conducting polymers such as poly(3,4-ethylene dioxythiophene) (PEDOT) and poly(styrene sulfonate) (PSS) (Cui and Martin, 2003; Pranti et al., 2018) are attracting considerable attention as alternatives to the metal electrodes and coatings for their biocom…”
BackgroundThe future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
“Other post-deposition protocols include: rinsing with dichloromethane (Yang et al 2005, Abidian et al 2006, 2007, 2009, Ludwig et al 2006, Abidian and Martin 2008, 2009), sonication (Sebaa et al 2013), and applying a few CV cycles in a cleaning solution (Mandal et al 2014, 2015, Pranti et al 2018).”
Method
Metadata
- Authors
- Pranti, A. S., Schander, A., Bödecker, A., & Lang, W.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 275
- Pages
- 382-393
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2887085927
- Cited by
- 138
- References
- 5
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PEDOT: PSS coating on gold microelectrodes with excellent stability and high charge injection capacity for chronic neural interfaces. https://app.cochat.ai/papers/10.1016/j.snb.2018.08.007
- The paper
- Pranti, A. S., Schander, A., Bödecker, A., & Lang, W. (2018). PEDOT: PSS coating on gold microelectrodes with excellent stability and high charge injection capacity for chronic neural interfaces. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.08.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.