The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Open accessAbstract
Abstract A new aptamer-based lateral flow strip assay has been designed and developed for on-site rapid detection of cortisol in sweat. Cortisol in sweat has been identified as a key biomarker to monitor physiological stress. A highly sensitive and specific cortisol sensor was achieved by conjugating cortisol-selective aptamers to the surface of gold nanoparticles (AuNPs). Aptamer-functionalized AuNPs are stable against salt-induced aggregation. When cortisol molecules are present in the sample, they interact with the designed aptamers causing their desorption from the AuNP surface. Free AuNPs can then be captured by reaction with cysteamine immobilized on the test zone of the lateral flow test strip. This enables the visual detection of cortisol within minutes. Important parameters that affect the detection sensitivity in both solution and lateral flow assays, such as the loading density of aptamers per AuNP, salt and cysteamine concentrations, were investigated to provide the optimum assay performance. This hand-held device successfully exhibited a visual limit of detection of 1 ng/mL, readily covering the normal range of free cortisol in sweat (8–140 ng/mL). No significant cross reactivity to other stress biomarkers was observed. The advantages of this paper-based biosensor over previously reported test strips include the use of aptamers (which are more stable, simpler to use and lower cost than antibodies) and a simplified lateral flow assay (LFA) strip design (without the use of complementary aptamers in the test line). The resulting LFA aptasensor provides a rapid, sensitive, user-friendly and cost-effective point of care device for cortisol detection in sweat and other biofluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Measuring stress in wildlife: techniques for quantifying glucocorticoids
Sheriff, M. J., Dantzer, B., Delehanty, B., Palme, R., & Boonstra, R. (2011) · Oecologia · doi:10.1007/s00442-011-1943-y · Cited by 919
Aptamers and Their Biological Applications
Song, K.-M., Lee, S., & Ban, C. (2012) · Sensors · doi:10.3390/s120100612 · Cited by 821
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Li, & Rothberg, L. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja048749n · Cited by 663
The NPY system in stress, anxiety and depression
Heilig, M. (2004) · Neuropeptides · doi:10.1016/j.npep.2004.05.002 · Cited by 614
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 576
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Extended gate field-effect-transistor for sensing cortisol stress hormone
Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M. (2021) · Communications Materials · doi:10.1038/s43246-020-00114-x · Cited by 158
Zamkah, A., Hui, T., Andrews, S., Dey, N., Shi, F., & Sherratt, R. S. (2020) · Biosensors · doi:10.3390/bios10040040 · Cited by 110
Metadata
- Authors
- Dalirirad, S., & Steckl, A. J.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 283
- Pages
- 79-86
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2902622097
- Cited by
- 259
- References
- 49
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aptamer-based lateral flow assay for point of care cortisol detection in sweat. https://app.cochat.ai/papers/10.1016/j.snb.2018.11.161
- The paper
- Dalirirad, S., & Steckl, A. J. (2019). Aptamer-based lateral flow assay for point of care cortisol detection in sweat. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.11.161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.