Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Aptamer-based lateral flow assay for point of care cortisol detection in sweat

Open access
Dalirirad, Shima, Steckl, Andrew J.·2019·Sensors and Actuators B: Chemical

Abstract

Abstract A new aptamer-based lateral flow strip assay has been designed and developed for on-site rapid detection of cortisol in sweat. Cortisol in sweat has been identified as a key biomarker to monitor physiological stress. A highly sensitive and specific cortisol sensor was achieved by conjugating cortisol-selective aptamers to the surface of gold nanoparticles (AuNPs). Aptamer-functionalized AuNPs are stable against salt-induced aggregation. When cortisol molecules are present in the sample, they interact with the designed aptamers causing their desorption from the AuNP surface. Free AuNPs can then be captured by reaction with cysteamine immobilized on the test zone of the lateral flow test strip. This enables the visual detection of cortisol within minutes. Important parameters that affect the detection sensitivity in both solution and lateral flow assays, such as the loading density of aptamers per AuNP, salt and cysteamine concentrations, were investigated to provide the optimum assay performance. This hand-held device successfully exhibited a visual limit of detection of 1 ng/mL, readily covering the normal range of free cortisol in sweat (8–140 ng/mL). No significant cross reactivity to other stress biomarkers was observed. The advantages of this paper-based biosensor over previously reported test strips include the use of aptamers (which are more stable, simpler to use and lower cost than antibodies) and a simplified lateral flow assay (LFA) strip design (without the use of complementary aptamers in the test line). The resulting LFA aptasensor provides a rapid, sensitive, user-friendly and cost-effective point of care device for cortisol detection in sweat and other biofluids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2018.11.161

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Cited by

See all 259

Metadata

Authors
Dalirirad, S., & Steckl, A. J.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2019-03
Volume
283
Pages
79-86
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2902622097
Cited by
259
References
49
FWCI
7.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aptamer-based lateral flow assay for point of care cortisol detection in sweat. https://app.cochat.ai/papers/10.1016/j.snb.2018.11.161
The paper
Dalirirad, S., & Steckl, A. J. (2019). Aptamer-based lateral flow assay for point of care cortisol detection in sweat. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.11.161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.