The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Open accessAbstract
Abstract A new aptamer-based lateral flow strip assay has been designed and developed for on-site rapid detection of cortisol in sweat. Cortisol in sweat has been identified as a key biomarker to monitor physiological stress. A highly sensitive and specific cortisol sensor was achieved by conjugating cortisol-selective aptamers to the surface of gold nanoparticles (AuNPs). Aptamer-functionalized AuNPs are stable against salt-induced aggregation. When cortisol molecules are present in the sample, they interact with the designed aptamers causing their desorption from the AuNP surface. Free AuNPs can then be captured by reaction with cysteamine immobilized on the test zone of the lateral flow test strip. This enables the visual detection of cortisol within minutes. Important parameters that affect the detection sensitivity in both solution and lateral flow assays, such as the loading density of aptamers per AuNP, salt and cysteamine concentrations, were investigated to provide the optimum assay performance. This hand-held device successfully exhibited a visual limit of detection of 1 ng/mL, readily covering the normal range of free cortisol in sweat (8–140 ng/mL). No significant cross reactivity to other stress biomarkers was observed. The advantages of this paper-based biosensor over previously reported test strips include the use of aptamers (which are more stable, simpler to use and lower cost than antibodies) and a simplified lateral flow assay (LFA) strip design (without the use of complementary aptamers in the test line). The resulting LFA aptasensor provides a rapid, sensitive, user-friendly and cost-effective point of care device for cortisol detection in sweat and other biofluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Measuring stress in wildlife: techniques for quantifying glucocorticoids
Sheriff, M. J., Dantzer, B., Delehanty, B., Palme, R., & Boonstra, R. (2011) · Oecologia · doi:10.1007/s00442-011-1943-y · Cited by 919
Aptamers and Their Biological Applications
Song, K.-M., Lee, S., & Ban, C. (2012) · Sensors · doi:10.3390/s120100612 · Cited by 821
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Li, & Rothberg, L. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja048749n · Cited by 663
The NPY system in stress, anxiety and depression
Heilig, M. (2004) · Neuropeptides · doi:10.1016/j.npep.2004.05.002 · Cited by 614
Storhoff, J. J., Lucas, A. D., Garimella, V., Bao, Y. P., & Müller, U. R. (2004) · Nature Biotechnology · doi:10.1038/nbt977 · Cited by 546
Huang, C.-C., Huang, Y.-F., Cao, Z., Tan, W., & Chang, H.-T. (2005) · Analytical Chemistry · doi:10.1021/ac050957q · Cited by 542
Neuropeptide Y: a stressful review
Reichmann, F., & Holzer, P. (2016) · Neuropeptides · doi:10.1016/j.npep.2015.09.008 · Cited by 490
Measuring cortisol in human psychobiological studies
Levine, A., Zagoory-Sharon, O., Feldman, R., Lewis, J. G., & Weller, A. (2007) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.08.025 · Cited by 472
Birch, J. R., & Racher, A. J. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.12.006 · Cited by 471
Aptasensors – the future of biosensing?
O'Sullivan, C. K. (2002) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-001-1189-3 · Cited by 410
A Gold Nanoparticle‐Based Aptamer Target Binding Readout for ATP Assay
Wang, J., Wang, L., Liu, X., Liang, Z., Song, S., Li, W., Li, G., & Fan, C. (2007) · Advanced Materials · doi:10.1002/adma.200602256 · Cited by 394
Cardiovascular consequences of cortisol excess
Whitworth, J. A., Williamson, P. M., Mangos, G., & Kelly, J. J. (2005) · Vascular Health and Risk Management · doi:10.2147/vhrm.2005.1.4.291 · Cited by 392
Paper-Based Bioassays Using Gold Nanoparticle Colorimetric Probes
Zhao, W., Ali, M. M., Aguirre, S. D., Brook, M. A., & Li, Y. (2008) · Analytical Chemistry · doi:10.1021/ac801008q · Cited by 338
An enzyme-linked oligonucleotide assay
Drolet, D. W., Moon-McDermott, L., & Romig, T. S. (1996) · Nature Biotechnology · doi:10.1038/nbt0896-1021 · Cited by 335
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Self-citationRecent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Cushing, Cortisol, and Cardiovascular Disease
Whitworth, J. A., Mangos, G. J., & Kelly, J. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.5.912 · Cited by 259
Aptamer-based colorimetric biosensing of dopamine using unmodified gold nanoparticles
Zheng, Y., Wang, Y., & Yang, X. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2011.03.077 · Cited by 240
Aggregation behaviour of gold nanoparticles in saline aqueous media
Pamies, R., Cifre, J. G. H., Espín, V. F., Collado-González, M., Baños, F. G. D., & de la Torre, J. G. (2014) · Journal of Nanoparticle Research · doi:10.1007/s11051-014-2376-4 · Cited by 220
Cortisol assays and diagnostic laboratory procedures in human biological fluids
Gatti, R., Antonelli, G., Prearo, M., Spinella, P., Cappellin, E., & De Palo, E. F. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.04.011 · Cited by 214
CHANGES IN CORTISOL METABOLISM FOLLOWING RIFAMPICIN THERAPY
Edwards, O., Galley, J. M., Courtenay-Evans, R. J., Hunter, J., & Tait, A. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91876-5 · Cited by 209
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Aptamer-based point-of-care diagnostic platforms
Dhiman, A., Kalra, P., Bansal, V., Bruno, J. G., & Sharma, T. K. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.02.060 · Cited by 206
Kelly, J., Mangos, G., Williamson, P., & Whitworth, J. (1998) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1998.tb02301.x · Cited by 204
The Detection of Cortisol in Human Sweat: Implications for Measurement of Cortisol in Hair
Russell, E., Koren, G., Rieder, M., & Van Uum, S. H. M. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31829daa0a · Cited by 193
Sanghavi, B. J., Moore, J. A., Chávez, J. L., Hagen, J. A., Kelley-Loughnane, N., Chou, C.-F., & Swami, N. S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.044 · Cited by 191
A physiologic approach to diagnosis of the Cushing syndrome.
Raff, H., & Findling, J. W. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-12-200306170-00010 · Cited by 186 · cited 1×
“Elevated cortisol levels with repeated activation leads to Cushing’s syndrome [5], which can result in severe fatigue, depression, anxiety, cognitive difficulties, obesity and cardiovascular disease [6,7].”
BackgroundStevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179
le Roux, C. W., Chapman, G. A., Kong, W. M., Dhillo, W. S., Jones, J., & Alaghband-Zadeh, J. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021532 · Cited by 146 · cited 1×
“As free cortisol accounts for all major activities related with cortisol in body [15], sweat as a”
BackgroundNeuropeptide Y (NPY) and depression: From animal studies to the human condition
Redrobe, J. P., Dumont, Y., & Quirion, R. (2002) · Life Sciences · doi:10.1016/s0024-3205(02)02159-8 · Cited by 146
Corbalán-Tutau, D., Madrid, J. A., Nicolás, F., & Garaulet, M. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2012.06.005 · Cited by 135
An LTCC-based microfluidic system for label-free, electrochemical detection of cortisol
Vasudev, A., Kaushik, A. K., Tomizawa, Y., Norena, N., & Bhansali, S. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.096 · Cited by 129
Tunable stringency aptamer selection and gold nanoparticle assay for detection of cortisol
Martin, J. A., Chávez, J. L., Chushak, Y. G., Chapleau, R. R., Hagen, J. A., & Kelley‐Loughnane, N. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7883-8 · Cited by 120
Adrenocortical responses to psychological stress and risk for hypertension
Al’Absi, M., & Arnett, D. K. (2000) · Biomedicine & Pharmacotherapy · doi:10.1016/s0753-3322(00)80065-7 · Cited by 99
Kumar, A., Aravamudhan, S., Gordic, M., Bhansali, S., & Mohapatra, S. S. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.09.035 · Cited by 75
One-step quantitative cortisol dipstick with proportional reading
Leung, W., Chan, P., Bosgoed, F., Lehmann, K., Renneberg, I., Lehmann, M., & Renneberg, R. (2003) · Journal of Immunological Methods · doi:10.1016/j.jim.2003.07.009 · Cited by 57
Nano RNA aptamer wire for analysis of vitamin B12
Selvakumar, L. S., & Thakur, M. S. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.05.020 · Cited by 47
Fernandez, R. E., Sanghavi, B. J., Farmehini, V., Chávez, J. L., Hagen, J. A., Kelley‐Loughnane, N., Chou, C., & Swami, N. S. (2016) · Electrochemistry Communications · doi:10.1016/j.elecom.2016.09.017 · Cited by 41
Development of a Sensitive Microarray Immunoassay for the Quantitative Analysis of Neuropeptide Y
Jia, M., Belyavskaya, E., Deuster, P. A., & Sternberg, E. M. (2012) · Analytical Chemistry · doi:10.1021/ac3014548 · Cited by 23
Point-of-use measurement of salivary cortisol levels
Yamaguchi, M., Yoshikawa, S., Tahara, Y., Niwa, D., Imai, Y., & Shetty, V. (2009) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2009.5398143 · Cited by 18
Martin, J. A., Smith, J. E., Warren, M., Chávez, J. L., Hagen, J. A., & Kelley‐Loughnane, N. (2015) · Journal of Visualized Experiments · doi:10.3791/52545 · Cited by 17
An optical sensing approach for the noninvasive transdermal monitoring of cortisol
Hwang, Y., Gupta, N., Ojha, Y. R., & Cameron, B. D. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2208971 · Cited by 8
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 576
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Extended gate field-effect-transistor for sensing cortisol stress hormone
Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M. (2021) · Communications Materials · doi:10.1038/s43246-020-00114-x · Cited by 158
Zamkah, A., Hui, T., Andrews, S., Dey, N., Shi, F., & Sherratt, R. S. (2020) · Biosensors · doi:10.3390/bios10040040 · Cited by 110
Metadata
- Authors
- Dalirirad, S., & Steckl, A. J.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 283
- Pages
- 79-86
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2902622097
- Cited by
- 259
- References
- 49
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.