The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2T MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection
Abstract
Abstract In this study, we newly developed a wearable electrochemical impedimetric immunosensor with a microfluidic channel and chamber based on a Ti3C2Tx MXene-loaded laser-burned graphene (LBG) flakes 3D electrode network for noninvasive point-of-care cortisol biomarker detection in human sweat. Polydimethylsiloxane (PDMS) was used as a substrate to fabricate flexible and stretchable patch sensor. Then, LBG was transferred onto the PDMS substrate by removing the polyamide (PI) film. A laser line gap creates a disconnection between the laser-burned graphene flakes, which consequently decreases the electrochemical performance of the LBG electrode. To solve the inter-flake disconnection problem caused by burning and transferring, highly conductive Ti3C2Tx MXene was loaded onto the electrode. The proposed flexible microfluidic system was fabricated using three-dimensional (3D) printed mold and PDMS. The fabricated sensor was attached to the skin to collect sweat, which then moved by natural pressure through the channel to the chamber. The successful loading of Ti3C2Tx MXene was confirmed using field emission scanning electron microscopy (FESEM), and X-ray photoelectron spectroscopy (XPS). Under optimized parameters, the Ti3C2Tx MXene/LBG/PDMS-based patch cortisol immunosensor exhibited linearity and a detection limit of 0.01–100 nM and 88 pM, respectively. Based on the analyses, it can be concluded that the developed strategy is well suited and conformable for point-of-care cortisol biomarker detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
Portable biosensor for monitoring cortisol in low-volume perspired human sweat
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-13684-7 · Cited by 231
Lee, H.-B., Meeseepong, M., Trung, T. Q., Kim, B.-Y., & Lee, N.-E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112133 · Cited by 153
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
2D metal carbides and nitrides (MXenes) for sensors and biosensors
Alwarappan, S., Nesakumar, N., Sun, D., Hu, T. Y., & Li, C.-Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113943 · Cited by 262
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55
Metadata
- Authors
- Nah, J. S., Barman, S. C., Zahed, M. A., Sharifuzzaman, M., Yoon, H., Park, C., Yoon, S., Zhang, S., & Park, J. Y.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 329
- Pages
- 129206
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3104094919
- Cited by
- 171
- References
- 3
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2T MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection. https://app.cochat.ai/papers/10.1016/j.snb.2020.129206
- The paper
- Nah, J. S., Barman, S. C., Zahed, M. A., Sharifuzzaman, M., Yoon, H., Park, C., Yoon, S., Zhang, S., & Park, J. Y. (2021). A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2T MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2020.129206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.