Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2T MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection

Nah, Joong San, Barman, Sharat Chandra, Zahed, Md Abu, Sharifuzzaman, Md., Yoon, Hyosang, Park, Chani, Yoon, Sanghyuk, Zhang, Shipeng, Park, Jae Yeong·2021·Sensors and Actuators B: Chemical

Abstract

Abstract In this study, we newly developed a wearable electrochemical impedimetric immunosensor with a microfluidic channel and chamber based on a Ti3C2Tx MXene-loaded laser-burned graphene (LBG) flakes 3D electrode network for noninvasive point-of-care cortisol biomarker detection in human sweat. Polydimethylsiloxane (PDMS) was used as a substrate to fabricate flexible and stretchable patch sensor. Then, LBG was transferred onto the PDMS substrate by removing the polyamide (PI) film. A laser line gap creates a disconnection between the laser-burned graphene flakes, which consequently decreases the electrochemical performance of the LBG electrode. To solve the inter-flake disconnection problem caused by burning and transferring, highly conductive Ti3C2Tx MXene was loaded onto the electrode. The proposed flexible microfluidic system was fabricated using three-dimensional (3D) printed mold and PDMS. The fabricated sensor was attached to the skin to collect sweat, which then moved by natural pressure through the channel to the chamber. The successful loading of Ti3C2Tx MXene was confirmed using field emission scanning electron microscopy (FESEM), and X-ray photoelectron spectroscopy (XPS). Under optimized parameters, the Ti3C2Tx MXene/LBG/PDMS-based patch cortisol immunosensor exhibited linearity and a detection limit of 0.01–100 nM and 88 pM, respectively. Based on the analyses, it can be concluded that the developed strategy is well suited and conformable for point-of-care cortisol biomarker detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2020.129206

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 171

Metadata

Authors
Nah, J. S., Barman, S. C., Zahed, M. A., Sharifuzzaman, M., Yoon, H., Park, C., Yoon, S., Zhang, S., & Park, J. Y.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2021-02
Volume
329
Pages
129206
ISSN
0925-4005 (ISSN-L)
OpenAlex
W3104094919
Cited by
171
References
3
FWCI
6.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2T MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection. https://app.cochat.ai/papers/10.1016/j.snb.2020.129206
The paper
Nah, J. S., Barman, S. C., Zahed, M. A., Sharifuzzaman, M., Yoon, H., Park, C., Yoon, S., Zhang, S., & Park, J. Y. (2021). A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2T MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2020.129206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.