Cited by 231Electrochemical sensors and biosensorsAdvanced biosensing and bioanalysis techniquesAdvanced Sensor and Energy Harvesting Materials

Portable biosensor for monitoring cortisol in low-volume perspired human sweat

Open access
Kinnamon, David, Ghanta, Ramesh, Lin, Kai-Chun, Muthukumar, Sriram, Prasad, Shalini·2017·Scientific Reports

Abstract

A non-faradaic label-free cortisol biosensor was demonstrated using MoS 2 nanosheets integrated into a nanoporous flexible electrode system. Low volume (1–5 μL) sensing was achieved through use of a novel sensor stack design comprised of vertically aligned metal electrodes confining semi-conductive MoS 2 nanosheets. The MoS 2 nanosheets were surface functionalized with cortisol antibodies towards developing an affinity biosensor specific to the physiological relevant range of cortisol (8.16 to 141.7 ng/mL) in perspired human sweat. Sensing was achieved by measuring impedance changes associated with cortisol binding along the MoS 2 nanosheet interface using electrochemical impedance spectroscopy. The sensor demonstrated a dynamic range from 1–500 ng/mL with a limit of detection of 1 ng/mL. A specificity study was conducted using a metabolite expressed in human sweat, Ethyl Glucuronide. Continuous dosing studies were performed during which the sensor was able to discriminate between four cortisol concentration ranges (0.5, 5, 50, 500 ng/mL) for a 3+ hour duration. Translatability of the sensor was shown with a portable form factor device, demonstrating a comparable dynamic range and limit of detection for the sensor. The device demonstrated a R 2 correlation value of 0.998 when comparing measurements to the reported impedance values of the benchtop instrumentation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-017-13684-7

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [11]Marieb, E. & Hoehn, K. Human Anatomy & Physiology. 8th edn, 1264 (Pearson, 2010).
  2. [18]Loechner, K. & Stratakis, C. Adrenal Insufficiency & Addison’s Disease. (National Institute of Diabetes and Digestive ad Kidney Diseases) (2014).

Cited by

Sorted by citations

Authors
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S.
Affiliations
The University of Texas at Dallas (US)
Corresponding author
Prasad, Shalini
Venue
Scientific Reports
Published
2017-10-17
Volume
7
Issue
1
Pages
13312-13312
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2762722043
Cited by
231
References
41
Citations by year
2026: 12 · 2025: 22 · 2024: 28 · 2023: 38 · 2022: 32 · 2021: 37 · 2020: 33 · 2019: 15 · 2018: 14
FWCI
7.05
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
University of Texas at Dallas
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
sweat analysis, MoS2 nanosheets, label-free biosensor, flexible electrodes, impedance spectroscopy, portable sensors, ethyl glucuronide, continuous dosing
MeSH terms
Disulfides, Humans, Hydrocortisone, Molybdenum, Sweat, Biosensing Techniques, Nanostructures, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review