Bionic prosthetic hands: A review of present technology and future aspirations
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · cited 1×
“accelerated rehabilitation program as the patient finds it more intuitive to learn how to control when they are receiving tactile feedback from the device.(38) With advancements in these technologies we may soon be able to re-wire the sensory input to the peripheral nervous system so that the central nervous system ca…”
BackgroundKuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482 · cited 1×
“has shownpromising resultswith theability toachieve intuitive control of multiple functions in a bionic hand.(21,22) An alternative system being developed to increase accuracy of myoelectric prostheses involves the implantation of bipolar differential electromyographic (EMG) electrodes within the muscle to create a sy…”
MethodDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1×
“many years after limb amputation and this property has been exploited by researchers using a technique called targeted motor reinnervation to increase the accuracy of myoelectrically controlled prostheses.(16) In this technique the nerves that once supplied the amputated limb muscles are surgically anastomosed into th…”
MethodKuiken, T. A., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 283
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257 · cited 2×
“suitable for direct fixation to the bone allowing considerable reductions in the weight of the constructs and conferring additional strength to the limb.(10) The additional strength provided by fixation to bone could also address the inability to weight bear through the prostheses, which is seen as one of their major…”
BackgroundDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 1×
“The reinnervated muscles act as biological amplifiers of motor commands in the amputated nerves and the surface electromyogram (EMG) can be used to enhance control of a robotic arm.(20) This technique”
MethodPrincipal components analysis based control of a multi-dof underactuated prosthetic hand
Matrone, G. C., Cipriani, C., Secco, E. L., Magenes, G., & Carrozza, M. C. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-16 · Cited by 137
Pino, G. D., Guglielmelli, E., & Rossini, P. M. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.03.001 · Cited by 120 · cited 2×
“With advancements in these technologies we may soon be able to re-wire the sensory input to the peripheral nervous system so that the central nervous system can perceive sensations coming from a bionic limb as if it were the natural limb.(37,39)”
BackgroundReferral of sensation to an advanced humanoid robotic hand prosthesis
Rosén, B., Ehrsson, H. H., Antfolk, C., Cipriani, C., Sebelius, F., & Lundborg, G. (2009) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844310903113107 · Cited by 113 · cited 1×
“Another approach is to try to replicate sensation by transferring stimuli from electronic sensors in the bionic limb to natural sensors on the skin of the limb stump which the patient perceives as coming from the amputated limb.(35,36) This has been difficult to achieve but recent work has successfully replicated more…”
BackgroundTargeted Reinnervation for Improved Prosthetic Function
Kuiken, T. (2006) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2005.10.001 · Cited by 111
Bio-inspired sensorization of a biomechatronic robot hand for the grasp-and-lift task
Edin, B. B., Ascari, L., Beccai, L., Roccella, S., Cabibihan, J., & Carrozza, M. C. (2008) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.01.017 · Cited by 102 · cited 1×
“For example information on grasp strength ensures a user will not break objects by holding them too tightly whilst information provided by detection of sound from microphones embedded in the hand ensures that the object will not slip out of the grip and be dropped.(31,32) This information, required for direct control…”
BackgroundNeuroprosthetic Applications of Electrical Stimulation
Grill, W. M., & Kirsch, R. F. (2000) · Assistive Technology · doi:10.1080/10400435.2000.10132006 · Cited by 89 · cited 1×
“With advancements in these technologies we may soon be able to re-wire the sensory input to the peripheral nervous system so that the central nervous system can perceive sensations coming from a bionic limb as if it were the natural limb.(37,39)”
Real time ECG artifact removal for myoelectric prosthesis control
Zhou, P., Lock, B. A., & Kuiken, T. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/006 · Cited by 89 · cited 1×
“It relies on complex algorithms to make sense of the massive amount of electrical activity in the stump, which is affected by everything from movement in the shoulder or elbow to the heartbeat.(11) Techniques such as electrical pattern recognition”
MethodSonomyography (SMG) Control for Powered Prosthetic Hand: A Study with Normal Subjects
Chen, X., Zheng, Y., Guo, J.-Y., & Shi, J. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.04.015 · Cited by 77 · cited 1×
“Sonomyography is an alternative method of limb control being developed that utilises ultrasound to measure the change in size of contracting muscles in the stump.(25,26) This”
MethodOccupational therapy protocol for amputees with targeted muscle reinnervation
Stubblefield, K. A., Miller, L. A., Lipschutz, R. D., & Kuiken, T. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.10.0138 · Cited by 66
Prosthetic Command Signals Following Targeted Hyper-Reinnervation Nerve Transfer Surgery
Kuiken, T., Miller, L. A., Lipschutz, R. D., Stubblefield, K. A., & Dumanian, G. A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616284 · Cited by 49
Development of prosthetic arm with pneumatic prosthetic hand and tendon-driven wrist
Takeda, H., TSUJIUCHI, N., KOIZUMI, T., Kan, H., Hirano, M., & Nakamura, Y. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333668 · Cited by 48 · cited 1×
“Currently available bionic hands are able to achieve a better range of functional grips including key, power, precision, index point and thumb park that confer far wider application of the replacements than previously achievable.(7) The drawback is that extensive training”
BackgroundRecent Trends in the Development and Evaluation of Assistive Robotic Manipulation Devices
Allin, S. J., Eckel, E., Markham, H., & Brewer, B. R. (2009) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2009.09.001 · Cited by 42 · cited 1×
“The modern prosthetic hand has been designed to closely approximate the natural limb in both form and function.(5) Despite the fact that the bionic hand was recently hailed as a triumph of engineering excellence(6) it remains an inferior replacement to the real thing and consequently there are a number of barriers to…”
BackgroundWeir, R. F., Troyk, P. R., DeMichele, G., & Kerns, D. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1616206 · Cited by 40 · cited 1×
“An alternative system being developed to increase accuracy of myoelectric prostheses involves the implantation of bipolar differential electromyographic (EMG) electrodes within the muscle to create a system capable of reading intra muscular EMG signals that increases the number of control sources available for prosthe…”
MethodEMG Signal Classification for Myoelectric Teleoperating a Dexterous Robot Hand
Wang, J. Z., Wang, R. C., Li, F., Jiang, M., & Jin, D. W. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615841 · Cited by 30
Early use of artificial sensibility in hand transplantation
Lanzetta, M., Perani, D., Anchisi, D., Rosén, B., Danna, M., Scifo, P., Fazio, F., & Lundborg, G. (2004) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.1080/02844310310019860 · Cited by 27 · cited 1×
“One approach is to utilise the concept of multimodal plasticity where loss of one sensory modality can be compensated by another.(33) For example hearing can partly compensate for the”
BackgroundHuman-like reflex control for an artificial hand
Folgheraiter, M., & Gini, G. C. (2004) · Biosystems · doi:10.1016/j.biosystems.2004.05.007 · Cited by 27
New Multifunctional Prosthetic Arm and hand Systems
Weir, R. F. F., Mitchell, M., Clark, S., Puchhammer, G., Kelley, K., Haslinger, M., Kumar, N., Hofbauer, R., Kuschnigg, P., Cornelius, V., et al. (2007) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2007.4353302 · Cited by 25 · cited 1×
“An alternative system being developed to increase accuracy of myoelectric prostheses involves the implantation of bipolar differential electromyographic (EMG) electrodes within the muscle to create a system capable of reading intra muscular EMG signals that increases the number of control sources available for prosthe…”
MethodA two DoF finger for a biomechatronic artificial hand
Carrozza, M. C., Massa, B., Dario, P., Zecca, M., Micera, S., & Pastacaldi, P. (2002) · Technology and Health Care · doi:10.3233/thc-2002-10201 · Cited by 23 · cited 1×
“The ultimate goal is to achieve a “Biomechatronic design” where the mechatronic system of the artificial hand is inspired by and works like the living limb.(27) To achieve this goal there would need to be integration of the prostheses with the central nervous system so that the replacement moves and is perceived as if…”
BackgroundZhou, P., Lowery, M. M., Weir, R. F. F., & Kuiken, T. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615670 · Cited by 23
Micera, S., Rigosa, J., Carpaneto, J., Citi, L., Raspopović, S., Guglielmelli, E., Benvenuto, A., Rossini, L., Pino, G. D., Cavallo, G., et al. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332764 · Cited by 19 · cited 1×
“The use of intraneural electrodes that are capable of delivering information directly to the peripheral afferent nerves within the residual limb has shown promising results in delivering meaningful sensations to amputees.(28) Delivering sensations through this approach has been shown to improve control as it allowed a…”
BackgroundTactile Substitution System for Transmitting a Few Words to a Prosthetic Hand User
Kim, G., Asakura, Y., Okuno, R., & Akazawa, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616094 · Cited by 14 · cited 1×
“loss of touch if auditory feedback is given when a bionic limb comes into contact with an object.(34) Another approach is to try to replicate sensation by transferring stimuli from electronic sensors in the bionic limb to natural sensors on the skin of the limb stump which the patient perceives as coming from the ampu…”
BackgroundMicera, S., Sergi, P. N., Carpaneto, J., Citi, L., Bossi, S., Koch, K.-P., Hoffmann, K.-P., Menciassi, A., Yoshida, K., & Dario, P. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260346 · Cited by 9
Use of muscle thickness change to control powered prosthesis: A pilot study
Guo, J., Chen, X., & Zheng, Y. (2009) · doi:10.1109/iembs.2009.5333640 · Cited by 3 · cited 1×
“Sonomyography is an alternative method of limb control being developed that utilises ultrasound to measure the change in size of contracting muscles in the stump.(25,26) This”
Method
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
A practical 3D-printed soft robotic prosthetic hand with multi-articulating capabilities
Mohammadi, A., Lavranos, J., Zhou, H., Mutlu, R., Alici, G., Tan, Y., Choong, P., & Oetomo, D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0232766 · Cited by 184
“of the lost functions by a prosthetic limb therefore has the potential to improve the quality of lives of those living with limb loss [1].”
Background3D Printed Flexure Hinges for Soft Monolithic Prosthetic Fingers
Mutlu, R., Alici, G., in het Panhuis, M., & Spinks, G. M. (2016) · Soft Robotics · doi:10.1089/soro.2016.0026 · Cited by 161
“34 Developing prosthetic devices made of smart materials fabricated using additive manufacturing methods can enable us to overcome these difficulties.”
Metadata
- Authors
- Clement, R. G. E., Bugler, K. E., & Oliver, C. W.
- Venue
- The Surgeon
- Publisher
- Elsevier BV
- Published
- 2011-12
- Volume
- 9
- Issue
- 6
- Pages
- 336-340
- ISSN
- 1479-666X (ISSN-L)
- OpenAlex
- W1999715507
- Cited by
- 189
- References
- 32
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.