Cited by 29Analytical chemistry methods developmentEnvironmental and Analytical Chemistry StudiesLaser-induced spectroscopy and plasma

Tungsten coil atomic emission spectrometry combined with dispersive liquid-liquid microextraction: a synergistic association for chromium determination in water samples

Open access
Vidal, Lorena, Silva, Sidnei G., Canals, Antonio, Nóbrega, Joaquim A.·2016·Talanta

Abstract

A novel and environment friendly analytical method is reported for total chromium determination and chromium speciation in water samples, whereby tungsten coil atomic emission spectrometry (WCAES) is combined with in situ ionic liquid formation dispersive liquid-liquid microextraction (in situ IL-DLLME). A two stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selection of the significant factor involved in the in situ IL-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were complexant concentration: 0.5% (or 0.1%); complexant type: DDTC; IL anion: PF6(-); [Hmim][Cl] IL amount: 60 mg; ionic strength: 0% NaCl; pH: 5 (or 2); centrifugation time: 10 min; and centrifugation speed: 1000 rpm. Under the optimized experimental conditions the method was evaluated and proper linearity was obtained with a correlation coefficient of 0.991 (5 calibration standards). Limits of detection and quantification for both chromium species were 3 and 10 µg L(-1), respectively. This is a 233-fold improvement when compared with chromium determination by WCAES without using preconcentration. The repeatability of the proposed method was evaluated at two different spiking levels (10 and 50 µg L(-1)) obtaining coefficients of variation of 11.4% and 3.6% (n=3), respectively. A certified reference material (SRM-1643e NIST) was analyzed in order to determine the accuracy of the method for total chromium determination and 112.3% and 2.5 µg L(-1) were the recovery (trueness) and standard deviation values, respectively. Tap, bottled mineral and natural mineral water samples were analyzed at 60 µg L(-1) spiking level of total Cr content at two Cr(VI)/Cr(III) ratios, and relative recovery values ranged between 88% and 112% showing that the matrix has a negligible effect. To our knowledge, this is the first time that combines in situ IL-DLLME and WCAES.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2015.04.023

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Vidal, L., Silva, S. G., Canals, A., & Nóbrega, J. A.
Affiliations
  • University of Alicante (ES)
  • Universidade Federal de São Carlos (BR)
Corresponding author
Vidal, Lorena
Venue
Talanta
Publisher
Elsevier BV
Published
2016-02
Volume
148
Pages
602-608
ISSN
0039-9140 (ISSN-L)
OpenAlex
W1993097247
Cited by
29
References
33
Citations by year
2025: 3 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 2 · 2018: 9 · 2017: 1 · 2016: 5
FWCI
3.91
Type
journal article
Language
en
Open access
Locations
  • Talanta (publishedVersion)
  • PubMed (publishedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion)
  • RUA, Repositorio Institucional de la Universidad de Alicante (Universidad de Alicante) (submittedVersion)
Funders
  • Fundação de Amparo à Pesquisa do Estado de São Paulo
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (2011/13288-7, 243/11, HBP-2010-0030)
  • Ministerio de Educación, Cultura y Deporte (PHB2010-0018-PC)
  • Generalitat Valenciana (ACOMP/2013/072)
  • Ministerio de Ciencia e Innovación (CTQ2011-23968)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
  • Physical Sciences › Engineering › Mechanics of Materials › Laser-induced spectroscopy and plasma
Keywords
dispersive liquid-liquid microextraction, ionic liquids, chromium speciation, total chromium determination, water samples, preconcentration, mineral water, tap water, bottled water

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review