CoChat

Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes

Shishov, Andrey, Pochivalov, Aleksei, Dubrovsky, Ivan, Bulatov, Andrey · 2023 · Talanta
Cited by 59

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

In the work limitations of deep eutectic solvents in the flow-based analysis are discussed. Deep eutectic solvents based on terpenes and fatty acids with low viscosity were studied as extraction solvents for liquid-liquid microextraction into a lab-in-syringe system for the first time. As a result an automated deep eutectic solvent-based microextraction approach was proposed. The procedure involved aspiration of deep eutectic solvent (based on terpene and fatty acid) and aqueous sample solution followed by phases mixing by a magnetic stirrer inside a syringe of flow system. After phase separation the extract phase was transferred from the syringe into a vial followed by analysis by a high-performance liquid chromatography with diode-array detection. The determination of Sudan I, Sudan II and Sudan III in chili-based sauces was considered as an analytical task. The mass-transfer intensification performed by the magnetic stirring inside the syringe allowed to perform fast (2 min) and efficient (extraction recoveries 87-95%) extraction. The limits of detection, calculated from a blank test based on 3σ, were from 0.003 to 0.005 mg kg-1, RSD was <9%. The microextraction procedure did not involve the use of hazardous organic solvents, only 100 μL of natural deep eutectic solvent was required for dyes preconcentration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2022.124243

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Metadata

Authors
Shishov, A., Pochivalov, A., Dubrovsky, I., & Bulatov, A.
Venue
Talanta
Publisher
Elsevier BV
Published
2023-04
Volume
255
Pages
124243
ISSN
0039-9140 (ISSN-L)
OpenAlex
W4313593220
Cited by
59
References
6
FWCI
4.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. https://app.cochat.ai/papers/10.1016/j.talanta.2022.124243
The paper
Shishov, A., Pochivalov, A., Dubrovsky, I., & Bulatov, A. (2023). Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. Talanta. https://doi.org/10.1016/j.talanta.2022.124243

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.