Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In the work limitations of deep eutectic solvents in the flow-based analysis are discussed. Deep eutectic solvents based on terpenes and fatty acids with low viscosity were studied as extraction solvents for liquid-liquid microextraction into a lab-in-syringe system for the first time. As a result an automated deep eutectic solvent-based microextraction approach was proposed. The procedure involved aspiration of deep eutectic solvent (based on terpene and fatty acid) and aqueous sample solution followed by phases mixing by a magnetic stirrer inside a syringe of flow system. After phase separation the extract phase was transferred from the syringe into a vial followed by analysis by a high-performance liquid chromatography with diode-array detection. The determination of Sudan I, Sudan II and Sudan III in chili-based sauces was considered as an analytical task. The mass-transfer intensification performed by the magnetic stirring inside the syringe allowed to perform fast (2 min) and efficient (extraction recoveries 87-95%) extraction. The limits of detection, calculated from a blank test based on 3σ, were from 0.003 to 0.005 mg kg-1, RSD was <9%. The microextraction procedure did not involve the use of hazardous organic solvents, only 100 μL of natural deep eutectic solvent was required for dyes preconcentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index
Płotka-Wasylka, J. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.013 · Cited by 2,328
Shishov, A., Terno, P., Moskvin, L., & Bulatov, A. (2020) · Talanta · doi:10.1016/j.talanta.2019.120209 · Cited by 107
Self-citationYıldırım, S., Cocovi-Solberg, D. J., Uslu, B., Solich, P., & Horstkotte, B. (2022) · Talanta · doi:10.1016/j.talanta.2022.123476 · Cited by 81
Chen, J., Li, X., Huang, A., Deng, W., & Xiao, Y. (2021) · Food Chemistry · doi:10.1016/j.foodchem.2021.130373 · Cited by 51
Sivrikaya Ozak, S., & Yılmaz, Y. (2020) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.118353 · Cited by 51
Ge, D., Shan, Z., Pang, T., Lu, X., & Wang, B. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03337-0 · Cited by 38
Cited by
Atypical Deep Eutectic Solvents: New Opportunities for Chemical Analysis
Shishov, A., El-Deen, A. K., Godunov, P., & Bulatov, A. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117752 · Cited by 51
Self-citationMafakheri, N., Shamsipur, M., & Babajani, N. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110010 · Cited by 47
Ozalp, O., & Soylak, M. (2023) · Analytical Letters · doi:10.1080/00032719.2023.2175212 · Cited by 28
Sadek, M., Sarkis, N., & Jangi, G. (2026) · Results in Chemistry · doi:10.1016/j.rechem.2026.103057 · Cited by 5
Metadata
- Authors
- Shishov, A., Pochivalov, A., Dubrovsky, I., & Bulatov, A.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2023-04
- Volume
- 255
- Pages
- 124243
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W4313593220
- Cited by
- 59
- References
- 6
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. https://app.cochat.ai/papers/10.1016/j.talanta.2022.124243
- The paper
- Shishov, A., Pochivalov, A., Dubrovsky, I., & Bulatov, A. (2023). Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. Talanta. https://doi.org/10.1016/j.talanta.2022.124243
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.