Lupus Anticoagulant (LAC) Testing in Patients with Inflammatory Status: Does C-Reactive Protein Interfere with LAC Test Results?
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
C-reactive protein, through its affinity with phospholipids present in reagents, can prolong PL-dependent clotting tests and lead to false-positive LA tests.
“C-reactive protein (an acute-phase reactant), through its affinity with the PL present in the reagents, can prolong PL-dependent clotting tests and lead to false-positive LA tests [23].”
From Lupus Anticoagulant Detection under the Magnifying Glass (2023) · cites this paper as [23]
The single patient positive for aPTT only had a higher CRP level and could be a false-positive result.
“this patient had a higher CRP level and could be a false-positive result, as described in the literature. 31,32”
From Clinical Relevance of Isolated Lupus Anticoagulant Positivity in Patients with Thrombotic Antiphospholipid Syndrome (2021) · cites this paper as [31]
Cofactor-independent antibodies have been shown to be relevant, although clinical data are rare.
“Also cofactor-independent antibodies have been shown to be relevant, although clinical data are rare. 31,32”
From Clinical Relevance of Isolated Lupus Anticoagulant Positivity in Patients with Thrombotic Antiphospholipid Syndrome (2021) · cites this paper as [31]
The presence of high levels of CRP can influence the LAC results, especially in the aPTT assay.
“The presence of high levels of CRP can influence the LAC results, especially in the aPTT assay. 31”
From Clinical Relevance of Isolated Lupus Anticoagulant Positivity in Patients with Thrombotic Antiphospholipid Syndrome (2021) · cites this paper as [31]
Cites
MIYAKIS, S., LOCKSHIN, M. D., ATSUMI, T., BRANCH, D. W., BREY, R. L., CERVERA, R., DERKSEN, R. H. W. M., DE GROOT, P. G., KOIKE, T., MERONI, P. L., et al. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01753.x · Cited by 7,203 · see citing works
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197 · see citing works
Brandt, J. T., Triplett, D. A., Alving, B., & Scharrer, I. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649901 · Cited by 993 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The hypercoagulable state in COVID-19: Incidence, pathophysiology, and management
Abou-Ismail, M. Y., Diamond, A., Kapoor, S., Arafah, Y., & Nayak, L. (2020) · Thrombosis Research · doi:10.1016/j.thromres.2020.06.029 · Cited by 694 · see citing works
Devreese, K. M. J., de Groot, P. G., de Laat, B., Erkan, D., Favaloro, E. J., Mackie, I., Martinuzzo, M., Ortel, T. L., Pengo, V., Rand, J. H., et al. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15047 · Cited by 439 · see citing works
Self-citationTripodi, A., Cohen, H., & Devreese, K. M. J. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14846 · Cited by 143 · see citing works
Self-citationAntiphospholipid antibody testing and standardization
Devreese, K. M. J. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12234 · Cited by 98 · see citing works
Self-citationYin, D., de Groot, P. G., Ninivaggi, M., Devreese, K. M. J., & de Laat, B. (2021) · Thrombosis and Haemostasis · doi:10.1055/a-1344-4271 · Cited by 36 · see citing works
Self-citationDiagnostic Challenges on the Laboratory Detection of Lupus Anticoagulant
Tripodi, A. (2021) · Biomedicines · doi:10.3390/biomedicines9070844 · Cited by 14 · see citing works
Lupus Anticoagulant Detection under the Magnifying Glass
Molinari, A. C., Martini, T., Banov, L., Ierardi, A., Leotta, M., Strangio, A., & Santoro, R. C. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12206654 · Cited by 9 · see citing works
Analytical dilemmas in lupus anticoagulant detection
Moore, G. W. (2023) · Exploration of Immunology · doi:10.37349/ei.2023.00104 · Cited by 5 · see citing works
Viewpoint: Lupus anticoagulant detection and interpretation in antiphospholipid syndrome
Efthymiou, M., Bertolaccini, M. L., & Cohen, H. (2024) · Rheumatology · doi:10.1093/rheumatology/kead623 · Cited by 5 · see citing works
Lupus Anticoagulant Testing in Challenging Situations: Navigating Complexities
Devreese, K. M. J. (2026) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.14490 · Cited by 2 · see citing works
Self-citation
- Authors
- Schouwers, S. M. E., Delanghe, J. R., & Devreese, K. M. J.
- Affiliations
- Ghent University Hospital (BE)
- Corresponding author
- Devreese, Katrien M.J.
- Venue
- Thrombosis Research
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 125
- Issue
- 1
- Pages
- 102-104
- ISSN
- 0049-3848 (ISSN-L)
- OpenAlex
- W2094575135
- Cited by
- 115
- References
- 3
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 10 · 2023: 11 · 2022: 9 · 2021: 22 · 2020: 32 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 4 · 2013: 1 · 2012: 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Thrombosis Research (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Keywords
- lupus anticoagulant, C-reactive protein, antiphospholipid syndrome, antiphospholipid antibodies, inflammatory status, laboratory test interference, coagulation tests, anti-beta2-glycoprotein I antibodies, anticardiolipin antibodies
- MeSH terms
- C-Reactive Protein, Humans, Inflammation, Lupus Coagulation Inhibitor, Antiphospholipid Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review