Intracellular oxidative stress and cadmium ions release induce cytotoxicity of unmodified cadmium sulfide quantum dots
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
OBJECTIVE To fully understand the cytotoxicity of after-degradation QDs, we synthesized CdS QDs and investigated its toxicity mechanism. METHODS Biomimetic method was proposed to synthesize cadmium sulfide (CdS) QDs. Thereafter MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide) assay was conducted to evaluate their cytotoxicity. To investigate the toxicity mechanism, we subsequently conducted intracellular reactive oxygen species (ROS) measurement with DCFH-DA, glutathione (GSH) measurement with DTNB, and cellular cadmium assay using atomic absorption spectrometer. Microsized CdS were simultaneously tested as a comparison. RESULTS MTT assay results indicated that CdS QDs are more toxic than microsized CdS especially at concentrations below 40 microg/ml. While microsized CdS did not trigger ROS elevation, CdS QDs increase ROS by 20-30% over control levels. However, they both deplete cellular GSH significantly at the medium concentration of 20 microg/ml. In the presence of NAC, cells are partially protected from CdS QDs, but not from microsized particles. Additionally, nearly 20% of cadmium was released from CdS nanoparticles within 24h, which also accounts for QDs' toxicity. CONCLUSION Intracellular ROS production, GSH depletion, and cadmium ions (Cd(2+)) release are possible mechanisms for CdS QDs' cytotoxicity. We also suggested that with QD concentration increasing, the principal toxicity mechanism changes from intracellular oxidative stress to Cd(2+) release.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidants, oxidative stress and the biology of ageing
Finkel, T., & Holbrook, N. J. (2000) · Nature · doi:10.1038/35041687 · Cited by 9,413
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891 · cited 2×
“Moreover, QDs, as nanoparticles, may be inhaled by human and reach the deep lung, where it could interact with the alveolar epithelium (Oberdorster et al., 2005).”
BackgroundQuantum Dots for Live Cells, in Vivo Imaging, and Diagnostics
Michalet, X., Pinaud, F. F., Bentolila, L. A., Tsay, J. M., Doose, S., Li, J. J., Sundaresan, G., Wu, A. M., Gambhir, S. S., & Weiss, S. (2005) · Science · doi:10.1126/science.1104274 · Cited by 7,790 · cited 1×
“…et al., 1998; Chan et al., 2002; Chan and Nie, 1998; Dabbousi et al., 1997; Han et al., 2001), QD shows great promise in biomedical imaging and electronics industries (Erogbogbo et al., 2008; Medintz et al., 2005; Michalet et al., 2005; Qi and Gao, 2008; Susumu et al., 2007; Weng et al., 2008).”
BackgroundSelf-citationQuantum Dot Bioconjugates for Ultrasensitive Nonisotopic Detection
Chan, W. C. W., & Nie, S. (1998) · Science · doi:10.1126/science.281.5385.2016 · Cited by 7,278 · cited 1×
“Owing to the unique optical and electrical properties (Bruchez et al., 1998; Chan et al., 2002; Chan and Nie, 1998; Dabbousi et al., 1997; Han et al., 2001), QD shows great promise in biomedical imaging and electronics industries (Erogbogbo et al., 2008; Medintz et al., 2005; Michalet et al., 2005;…”
BackgroundQuantum dot bioconjugates for imaging, labelling and sensing
Medintz, I. L., Uyeda, H. T., Goldman, E. R., & Mattoussi, H. (2005) · Nature Materials · doi:10.1038/nmat1390 · Cited by 6,229 · cited 1×
“…et al., 1998; Chan et al., 2002; Chan and Nie, 1998; Dabbousi et al., 1997; Han et al., 2001), QD shows great promise in biomedical imaging and electronics industries (Erogbogbo et al., 2008; Medintz et al., 2005; Michalet et al., 2005; Qi and Gao, 2008; Susumu et al., 2007; Weng et al., 2008).”
BackgroundIn vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,772 · cited 2×
“, 2004), which reduces their toxicity; however, when subcellular localization of QDs or their local environment changes, or after they are retained in cells or body for a long term, the degradation of coatings can occur and expose their inorganic core (Akerman et al., 2002; Derfus et al., 2004; Gao et al., 2004; Lovri…”
BackgroundDabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
Probing the Cytotoxicity of Semiconductor Quantum Dots
Derfus, A. M., Chan, W. C. W., & Bhatia, S. N. (2004) · Nano Letters · doi:10.1021/nl0347334 · Cited by 3,391 · cited 13×
“, 2004), which reduces their toxicity; however, when subcellular localization of QDs or their local environment changes, or after they are retained in cells or body for a long term, the degradation of coatings can occur and expose their inorganic core (Akerman et al., 2002; Derfus et al., 2004; Gao et al., 2004; Lovri…”
BackgroundInfluentialIn Vivo Imaging of Quantum Dots Encapsulated in Phospholipid Micelles
Dubertret, B., Skourides, P., Norris, D. J., Noireaux, V., Brivanlou, A. H., & Libchaber, A. (2002) · Science · doi:10.1126/science.1077194 · Cited by 3,019
Cited by
Yang, Y., Cui, J., Zheng, M., Hu, C., Tan, S., Xiao, Y., Yang, Q., & Liu, Y. (2012) · Chem. Commun. · doi:10.1039/c1cc15678k · Cited by 995
Quantum dots: bright and versatile in vitro and in vivo fluorescence imaging biosensors
Wegner, K. D., & Hildebrandt, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00532e · Cited by 984
Soenen, S. J., Rivera-Gil, P., Montenegro, J.-M., Parak, W. J., De Smedt, S. C., & Braeckmans, K. (2011) · Nano Today · doi:10.1016/j.nantod.2011.08.001 · Cited by 699
New Generation Cadmium-Free Quantum Dots for Biophotonics and Nanomedicine
Xu, G., Zeng, S., Zhang, B., Swihart, M. T., Yong, K.-T., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00290 · Cited by 587
Meta-analysis of cellular toxicity for cadmium-containing quantum dots
Oh, E., Liu, R., Nel, A., Gemill, K. B., Bilal, M., Cohen, Y., & Medintz, I. L. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.338 · Cited by 502
Toxicity assessment of nanomaterials: methods and challenges
Dhawan, A., & Sharma, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3996-x · Cited by 466
Photosynthetic semiconductor biohybrids for solar-driven biocatalysis
Cestellos-Blanco, S., Zhang, H., Kim, J. M., Shen, Y.-X., & Yang, P. (2020) · Nature Catalysis · doi:10.1038/s41929-020-0428-y · Cited by 463
Cytotoxicity and oxidative stress induced by different metallic nanoparticles on human kidney cells
Pujalté, I., Passagne, I., Brouillaud, B., Tréguer, M., Durand, E., Ohayon-Courtès, C., & L'Azou, B. (2011) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-8-10 · Cited by 398
“, [63], suggesting that CdS QDs have the capacity to generate free radicals indirectly and induce oxidative stress and cytotoxicity by releasing Cd in cells.”
BackgroundIn vitro and in vivo toxicity assessment of nanoparticles
Kumar, V., Sharma, N., & Maitra, S. S. (2017) · International Nano Letters · doi:10.1007/s40089-017-0221-3 · Cited by 391
Brunetti, V., Chibli, H., Fiammengo, R., Galeone, A., Malvindi, M. A., Vecchio, G., Cingolani, R., Nadeau, J. L., & Pompa, P. P. (2013) · Nanoscale · doi:10.1039/c2nr33024e · Cited by 346
Functionalized Quantum Dots for Biosensing and Bioimaging and Concerns on Toxicity
Wang, Y., Hu, R., Lin, G., Roy, I., & Yong, K.-T. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am302030a · Cited by 332
Self-citationBiocompatible Semiconductor Quantum Dots as Cancer Imaging Agents
McHugh, K. J., Jing, L., Behrens, A. M., Jayawardena, S., Tang, W., Gao, M., Langer, R., & Jaklenec, A. (2018) · Advanced Materials · doi:10.1002/adma.201706356 · Cited by 318
Gelatin nanoparticles: a potential candidate for medical applications
Yasmin, R., Shah, M., Khan, S. A., & Ali, R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0009 · Cited by 195
Possible genotoxic mechanisms of nanoparticles: Criteria for improved test strategies
Donaldson, K., Poland, C. A., & Schins, R. P. F. (2010) · Nanotoxicology · doi:10.3109/17435390.2010.482751 · Cited by 170
“There is abundant evidence that NP can deplete antioxidants so increasing the potential for endogenous steady state free radical levels to cause oxidative damage to DNA (Park et al. 2008; Li et al. 2009; Wang et al. 2009).”
Background
Metadata
- Authors
- Li, K. G., Chen, J. T., Bai, S. S., Wen, X., Song, S. Y., Yu, Q., Li, J., & Wang, Y. Q.
- Venue
- Toxicology in Vitro
- Publisher
- Elsevier BV
- Published
- 2009-09
- Volume
- 23
- Issue
- 6
- Pages
- 1007-1013
- ISSN
- 0887-2333 (ISSN-L)
- OpenAlex
- W2036861771
- Cited by
- 206
- References
- 52
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.