A 3D microfluidic liver model for high throughput compound toxicity screening in the OrganoPlate®
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
We report the development, automation and validation of a 3D, microfluidic liver-on-a-chip for high throughput hepatotoxicity screening, the OrganoPlate LiverTox™. The model is comprised of aggregates of induced pluripotent stem cell (iPSC)-derived hepatocytes (iHep) seeded in an extracellular matrix in the organ channel and co-cultured with endothelial cells and THP-1 monoblasts differentiated to macrophages seeded in the vascular channel of the 96 well Mimetas OrganoPlate 2-lane. A key component of high throughput screening is automation and we report a protocol to seed, dose, collect and replenish media and add assay reagents in the OrganoPlate 2-lane using a standard laboratory liquid handling robot. A combination of secretome measurements and image-based analysis was used to demonstrate stable 15 day cell viability, albumin and urea secretion. Over the same time-period, CYP3A4 activity increased and alpha-fetoprotein secretion decreased suggesting further maturation of the iHeps. Troglitazone, a clinical hepatotoxin, was chosen as a control compound for validation studies. Albumin, urea, hepatocyte nuclear size and viability staining provided Robust Z’factors > 0.2 in plates treated 72 h with 180 μM troglitazone compared with a vehicle control. The viability assay provided the most robust statistic for a Robust Z’ factor = 0.6. A small library of 159 compounds with known liver effects was added to the OrganoPlate LiverTox model for 72 h at 50 μM and the Toxicological Prioritization scores were calculated. A follow up dose-response evaluation of select hits revealed the albumin assay to be the most sensitive in calculating TC50 values. This platform provides a robust, novel model which can be used for high throughput hepatotoxicity screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Ostapowicz, G., Fontana, R. J., Schiødt, F. V., Larson, A., Davern, T. J., Han, S. H. B., McCashland, T. M., Shakil, A. O., Hay, J. E., Hynan, L., et al. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-12-200212170-00007 · Cited by 2,227
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Stepan, A. F., Walker, D. P., Bauman, J., Price, D. A., Baillie, T. A., Kalgutkar, A. S., & Aleo, M. D. (2011) · Chemical Research in Toxicology · doi:10.1021/tx200168d · Cited by 698
Onakpoya, I. J., Heneghan, C. J., & Aronson, J. K. (2016) · BMC Medicine · doi:10.1186/s12916-016-0553-2 · Cited by 616
FDA-approved drug labeling for the study of drug-induced liver injury
Chen, M., Vijay, V., Shi, Q., Liu, Z., Fang, H., & Tong, W. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2011.05.007 · Cited by 406
Endocrine Profiling and Prioritization of Environmental Chemicals Using ToxCast Data
Reif, D. M., Martin, M. T., Tan, S. W., Houck, K. A., Judson, R. S., Richard, A. M., Knudsen, T. B., Dix, D. J., & Kavlock, R. J. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.1002180 · Cited by 405
Chen, M., Suzuki, A., Thakkar, S., Yu, K., Hu, C., & Tong, W. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.02.015 · Cited by 398
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Microfluidic Devices: A Tool for Nanoparticle Synthesis and Performance Evaluation
Gimondi, S., Ferreira, H., Reis, R. L., & Neves, N. M. (2023) · ACS Nano · doi:10.1021/acsnano.3c01117 · Cited by 376
Yang, S.-M., Lv, S., Zhang, W., & Cui, Y. (2022) · Sensors · doi:10.3390/s22041620 · Cited by 299
Organoids: The current status and biomedical applications
Yang, S., Hu, H., Kung, H., Zou, R., Dai, Y., Hu, Y., Wang, T., Lv, T., Yu, J., & Li, F. (2023) · MedComm · doi:10.1002/mco2.274 · Cited by 266
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
3d organ-on-a-chip: the convergence of microphysiological systems and organoids
Baptista, L. S., Porrini, C., Kronemberger, G. S., Kelly, D. J., & Perrault, C. M. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.1043117 · Cited by 90
“In general, the process is not automated, with few exceptions (Bircsak et al., 2021).”
BackgroundMethodInfluentialLiver three-dimensional cellular models for high-throughput chemical testing
Yang, S., Ooka, M., Margolis, R. J., & Xia, M. (2023) · Cell Reports Methods · doi:10.1016/j.crmeth.2023.100432 · Cited by 75
Kammerer, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910214 · Cited by 59
“Further, 159 compounds were tested on this system showing that it is suitable for high-throughput screens, but sensitivities and specificities were unfortunately not calculated [136].”
BackgroundMicrofluidic Liver-on-a-Chip for Preclinical Drug Discovery
Fu, J., Qiu, H., & Tan, C. S. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15041300 · Cited by 42
“(C) reproduced with permission of [20], Copyright © 2021.”
BackgroundMethodInfluentialIn vitro functional models for human liver diseases and drug screening: beyond animal testing
Paradiso, A., Volpi, M., Rinoldi, C., Celikkin, N., Contessi Negrini, N., Bilgen, M., Dallera, G., Pierini, F., Costantini, M., Święszkowski, W., et al. (2023) · Biomaterials Science · doi:10.1039/d1bm01872h · Cited by 40
Kim, M. K., Jeong, W., Jeon, S., & Kang, H.-W. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1305023 · Cited by 38
A Model of Hepatic Steatosis with Declined Viability and Function in a Liver-Organ-on-a-Chip
Wiriyakulsit, N., Keawsomnuk, P., Thongin, S., Ketsawatsomkron, P., & Muta, K. (2023) · Scientific Reports · doi:10.1038/s41598-023-44198-0 · Cited by 29
Guo, K., & van den Beucken, T. (2024) · Cell & Bioscience · doi:10.1186/s13578-024-01317-2 · Cited by 28
“As a result, these cells are currently widely used for high-throughput hep-atotoxicity screening [60–62] and even transcriptomic compound toxicity research [63, 64].”
MethodQuality criteria for in vitro human pluripotent stem cell-derived models of tissue-based cells
Pistollato, F., Bal-Price, A., Coecke, S., Parvatam, S., Pamies, D., Czysz, K., Hao, J., Kee, K., Teo, A. K. K., Niu, S., et al. (2022) · Reproductive Toxicology · doi:10.1016/j.reprotox.2022.06.003 · Cited by 10
Stem Cell-Based Strategies: The Future Direction of Bioartificial Liver Development
Feng, L., Wang, Y., Fu, Y., Li, T., & He, G. (2024) · Stem Cell Reviews and Reports · doi:10.1007/s12015-023-10672-5 · Cited by 9
“Compared with the above rough and self-assembled 3D cultivation modes, microfluidic devices [147], and 3D bioprinting [148, 149] are regarded as more sophisticated and precise.”
A high-throughput microphysiological system to quantify key events leading to liver fibrosis
Schmidt, S., & Suter-Dick, L. (2025) · Toxicology · doi:10.1016/j.tox.2025.154248 · Cited by 3
Metadata
- Authors
- Bircsak, K. M., DeBiasio, R., Miedel, M., Alsebahi, A., Reddinger, R., Saleh, A., Shun, T., Vernetti, L. A., & Gough, A.
- Venue
- Toxicology
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 450
- Pages
- 152667
- ISSN
- 0300-483X (ISSN-L)
- OpenAlex
- W3115778807
- Cited by
- 192
- References
- 48
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.