Improvement in enzymolysis efficiency and changes in conformational attributes of corn gluten meal by dual-frequency slit ultrasonication action
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The influences of dual-frequency slit ultrasound (DFSU) pretreatment with various working parameters on the enzymolysis efficiency and conformational characteristics of corn gluten meal (CGM) were studied. Results indicated that under the conditions of ultrasonic power density of 80 W/L, time of 30 min, ultrasonic intermittent ratio of 5:2 s/s, temperature of 30 °C, and substrate concentration of 50 g/L, the relative enzymolysis efficiency (REE) of CGM reached a maximum of 21.05%, and the protein dissolution rate was 68.50%. In addition, ultrasonication had considerable impact on the conformation of CGM and consequently improved the susceptibility to alcalase proteolysis. Changes in free sulfhydryl (SHF) and disulfide bonds (SS) groups indicated spatial conformation of CGM was altered following sonication (sonochemical) treatment. Fourier Transform Infrared Spectrum (FITR) analysis showed a reduction in α-helix and β-turn content; and an increase in β-sheet and random coil content of CGM. Alterations in the particle size, particle size distribution, microstructure and surface roughness (Ra, Rq) indicated generation of smaller and more uniform protein fragments of CGM by sonochemical pretreatment. The proposed mechanism of sonicated CGM was elaborated. Our findings suggest that using DFSU in pretreating CGM may be an efficacious approach to enhance proteolysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemat, F., Rombaut, N., Sicaire, A.-G., Meullemiestre, A., Fabiano-Tixier, A.-S., & Abert-Vian, M. (2017) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2016.06.035 · Cited by 3,278
Advances in ultrasound assisted extraction of bioactive compounds from cash crops–A review
Wen, C., Zhang, J., Zhang, H., Dzah, C. S., Zandile, M., Duan, Y., Ma, H., & Luo, X. (2018) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2018.07.018 · Cited by 721
Self-citationYang, X., Li, Y., Li, S., Oladejo, A. O., Wang, Y., Huang, S., Zhou, C., Wang, Y., Mao, L., Zhang, Y., et al. (2017) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2017.03.001 · Cited by 121
Self-citationYang, X., Li, Y., Li, S., Oladejo, A. O., Wang, Y., Huang, S., Zhou, C., Ye, X., Ma, H., & Duan, Y. (2018) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2017.08.028 · Cited by 100
Self-citationMa, H., Huang, L., Peng, L., Wang, Z., & Yang, Q. (2015) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2014.10.020 · Cited by 40
Self-citation
Cited by
Xu, B., Azam, S. M. R., Feng, M., Wu, B., Yan, W., Zhou, C., & Ma, H. (2021) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2021.105855 · Cited by 108
Self-citationUltrasound-assisted enzymatic digestion for efficient extraction of proteins from quinoa
Yang, C., Liu, W., Zhu, X., Zhang, X., Wei, Y., Huang, J., Yang, F., & Yang, F. (2024) · LWT · doi:10.1016/j.lwt.2024.115784 · Cited by 72
Xu, B., Feng, M., Tiliwa, E. S., Yan, W., Wei, B., Zhou, C., Ma, H., Wang, B., & Chang, L. (2022) · LWT · doi:10.1016/j.lwt.2021.113037 · Cited by 66
Self-citation
Metadata
- Authors
- Wang, Y., Zhang, Z., He, R., Liu, D., Kumah Mintah, B., Dabbour, M., & Ma, H.
- Venue
- Ultrasonics Sonochemistry
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 64
- Pages
- 105038
- ISSN
- 1350-4177 (ISSN-L)
- OpenAlex
- W3006625003
- Cited by
- 45
- References
- 5
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.