A compact field guide to the study of microsaccades: Challenges and functions
Open accessThe DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Abstract
Following a period of quiescence at the end of last century, the study of microsaccades has now regained strong impetus and broad attention within the vision research community. This new wave of interest, partly fueled by the advent of a new generation of high-resolution eyetrackers, has attracted new researchers and led to new ideas. Old hypothesis have been revisited and new ones formulated. This article is designed to serve as a practical guide for researchers in the field. Because of the history of the field and the difficulty of measuring very small eye movements, the study of microsaccades presents peculiar challenges. Here, we summarize some of the main challenges and describe methods for assessing and improving the quality of the recordings. Furthermore, we examine how these experimental challenges have influenced analysis of the visual functions of microsaccades and critically review current evidence on three long-debated proposals: the maintenance of fixation, the prevention of visual fading, and the exploration of fine spatial detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IARBUS, A. L. (1967) · Medical Entomology and Zoology · Cited by 3,319
Yarbus, A. L. (1967) · doi:10.1007/978-1-4899-5379-7 · Cited by 3,304 · cited 1×
“In the middle of last century, it became possible for the first time to immobilize stimuli on the retina, a laboratory condition known as retinal stabilization (Ditchburn & Ginsborg, 1952; Riggs & Ratliff, 1952; Yarbus, 1967).”
BackgroundHuman photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167 · cited 6×
“Because there is a clear distinction at the functional and anatomical level between the foveola and the rest of the retina (Curcio et al., 1990), a reasonable approach is to separate the small saccades that maintain the object of interest within this region—i.e., those that cause a large overlap in…”
BackgroundInfluentialEye Tracking: A comprehensive guide to methods and measures
Holmqvist, K., Nyström, M., Andersson, R., Dewhurst, R. J., Jarodzka, H. M., & van de Weijer, J. (2015) · Lund University Publications (Lund University) · Cited by 2,919
Saccade target selection and object recognition: Evidence for a common attentional mechanism
Deubel, H., & Schneider, W. X. (1996) · Vision Research · doi:10.1016/0042-6989(95)00294-4 · Cited by 1,979 · cited 1×
“In the literature , gaze localization errors have been reported to be less than 0.1° for the DPI eyetracker (Deubel & Schneider, 1996) and in the range 0.3–1° for the most common video eyetrackers (Blignaut & Wium, 2014; Holmqvist et al., 2011).”
BackgroundInfluentialA Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field
(1963) · IEEE Transactions on Bio-medical Electronics · doi:10.1109/tbmel.1963.4322822 · Cited by 1,838 · cited 2×
“Head movements are problematic also for the DPI and coil eyetrackers (Crane & Steele, 1985; Robinson, 1963)—but not for the Revolving Field Monitor (Epelboim et al.”
BackgroundA method of measuring eye movements using a scleral search coil in a magnetic field
Robinson, D. A. (1963) · Medical Entomology and Zoology · Cited by 1,709
Transient induced gamma-band response in EEG as a manifestation of miniature saccades
Yuval-Greenberg, S., Tomer, O., Keren, A. S., Nelken, I., & Deouell, L. Y. (2008) · Neuron · doi:10.1016/j.neuron.2008.03.027 · Cited by 776 · cited 1×
“For example Yuval-Greenberg et al. (2008) showed that a certain class of gamma-band EEG responses, traditionally associated with higher cognitive functions, is time-locked with the onset of microsaccades , possibly reflecting a saccadic spike potential rather than higher-order processes.”
BackgroundPrecise recording of human eye movements
Collewijn, H., van der Mark, F., & Jansen, T. C. (1975) · Vision Research · doi:10.1016/0042-6989(75)90098-x · Cited by 718
Steinman, R. M., Haddad, G. M., Skavenski, A. A., & Wyman, D. (1973) · Science · doi:10.1126/science.181.4102.810 · Cited by 528 · cited 4×
“All these results support the notion that—although not strictly necessary (Steinman et al., 1967, 1973),—fixational saccades normally help maintaining accurate fixation on point.”
BackgroundResultInfluential
Cited by
King, A. J., Bol, N., Cummins, R. G., & John, K. K. (2019) · Communication Methods and Measures · doi:10.1080/19312458.2018.1558194 · Cited by 196
“Saccade-based metrics are used relatively infrequently in communication research as an operational measure (see Bol, Boerman et al., 2016), and there are many challenges in measuring saccades (see Poletti & Rucci, 2016).”
BackgroundAttentional bias towards negative stimuli in healthy individuals and the effects of trait anxiety
Veerapa, E., Grandgenevre, P., El Fayoumi, M., Vinnac, B., Haelewyn, O., Szaffarczyk, S., Vaiva, G., & D’Hondt, F. (2020) · Scientific Reports · doi:10.1038/s41598-020-68490-5 · Cited by 73
Metadata
- Authors
- Poletti, M., & Rucci, M.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2016-01
- Volume
- 118
- Pages
- 83-97
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2057526499
- Cited by
- 164
- References
- 77
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A compact field guide to the study of microsaccades: Challenges and functions. https://app.cochat.ai/papers/10.1016/j.visres.2015.01.018
- The paper
- Poletti, M., & Rucci, M. (2016). A compact field guide to the study of microsaccades: Challenges and functions. Vision Research. https://doi.org/10.1016/j.visres.2015.01.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.