CoChat

Photoacoustic flow cytometry

Open access
Galanzha, Ekaterina I., Zharov, Vladimir P. · 2012 · Methods
Cited by 159

The DOI matches its Crossref record.

Abstract

Conventional flow cytometry using scattering and fluorescent detection methods has been a fundamental tool of biological discoveries for many years. Invasive extraction of cells from a living organism, however, may lead to changes in cell properties and prevents the long-term study of cells in their native environment. Here, we summarize recent advances of new generation flow cytometry for in vivo noninvasive label-free or targeted detection of cells in blood, lymph, bone, cerebral and plant vasculatures using photoacoustic (PA) detection techniques, multispectral high-pulse-repetition-rate lasers, tunable ultrasharp (up to 0.8 nm) rainbow plasmonic nanoprobes, positive and negative PA contrasts, in vivo magnetic enrichment, time-of-flight cell velocity measurement, PA spectral analysis, and integration of PA, photothermal (PT), fluorescent, and Raman methods. Unique applications of this tool are reviewed with a focus on ultrasensitive detection of normal blood cells at different functional states (e.g., apoptotic and necrotic) and rare abnormal cells including circulating tumor cells (CTCs), cancer stem cells, pathogens, clots, sickle cells as well as pharmokinetics of nanoparticles, dyes, microbubbles and drug nanocarriers. Using this tool we discovered that palpation, biopsy, or surgery can enhance CTC release from primary tumors, increasing the risk of metastasis. The novel fluctuation flow cytometry provided the opportunity for the dynamic study of blood rheology including red blood cell aggregation and clot formation in different medical conditions (e.g., blood disorders, cancer, or surgery). Theranostics, as a combination of PA diagnosis and PT nanobubble-amplified multiplex therapy, was used for eradication of CTCs, purging of infected blood, and thrombolysis of clots using PA guidance to control therapy efficiency. In vivo flow cytometry using a portable fiber-based devices can provide a breakthrough platform for early diagnosis of cancer, infection and cardiovascular disorders with a potential to inhibit, if not prevent, metastasis, sepsis, and strokes or heart attack by well-timed personalized therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ymeth.2012.06.009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 65

  1. H.M. Shapiro, Practical Flow Cytometry, fourth ed., Wiley-Liss, New York, 2003. · DOI · Paper page
  2. Tuchin, 2011, Cytometry A, 79A, 737, 10.1002/cyto.a.21143 · doi:10.1002/cyto.a.21143
  3. Zharov, 2004, Proc. SPIE, 5320, 256
  4. Galanzha, 2004, Proc. SPIE, 5474, 204, 10.1117/12.578915 · doi:10.1117/12.578915
  5. Galanzha, 2005, Lymphology, 38, 181
  6. Galanzha, 2005, J. Biomed. Opt., 10, 54018, 10.1117/1.2060567 · doi:10.1117/1.2060567
  7. Zharov, 2005, Opt. Lett., 30, 628, 10.1364/OL.30.000628 · doi:10.1364/ol.30.000628
  8. Zharov, 2005, J. Biomed. Opt., 10, 51502, 10.1117/1.2070167 · doi:10.1117/1.2070167
  9. Zharov, 2006, J. Cell. Biochem., 97, 916, 10.1002/jcb.20766 · doi:10.1002/jcb.20766
  10. Zharov, 2006, Opt. Lett., 31, 3623, 10.1364/OL.31.003623 · DOI · Paper page
  11. Zharov, 2006, J. Biomed. Opt., 11, 054034, 10.1117/1.2355666 · doi:10.1117/1.2355666
  12. Zharov, 2006, Proc. SPIE, 6085, 10
  13. Zharov, 2007, Cytometry A, 71A, 191, 10.1002/cyto.a.20384 · doi:10.1002/cyto.a.20384
  14. Zharov, 2007, J. Biomed. Opt., 12, 0551503, 10.1117/1.2793746 · DOI · Paper page
  15. Galanzha, 2007, Lymphat. Res. Biol., 5, 1127, 10.1089/lrb.2007.5103 · doi:10.1089/lrb.2007.5103
  16. Galanzha, 2007, World J. Gastroenterol., 13, 192218, 10.3748/wjg.v13.i2.192 · doi:10.3748/wjg.v13.i2.192
  17. V. Kalchenko, A. Harmelin, I. Fine, V. Zharov, et al., Proc. SPIE 6436 (2007) 64360. · doi:10.1117/12.716636
  18. Kalchenko, 2007, J. Biomed. Opt., 12, 052002-1-4, 10.1117/1.2778695 · doi:10.1117/1.2778695
  19. Galanzha, 2008, Cytometry A, 73A, 884, 10.1002/cyto.a.20587 · DOI
  20. Olszewski, 2008, Cytometry A, 73A, 1111, 10.1002/cyto.a.20654 · doi:10.1002/cyto.a.20654
  21. Galanzha, 2009, J. Biophotonics, 2, 528, 10.1002/jbio.200910046 · DOI
  22. Tanev, 2009, J. Biophotonics, 2, 505520, 10.1002/jbio.200910039 · doi:10.1002/jbio.200910039
  23. Kim, 2009, Nat. Nanotechnol., 4, 688, 10.1038/nnano.2009.231 · DOI · Paper page
  24. Galanzha, 2009, Nat. Nanotechnol., 4, 855, 10.1038/nnano.2009.333 · DOI · Paper page
  25. Biris, 2009, J. Biomed. Opt., 14, 021006, 10.1117/1.3119145 · DOI
  26. Galanzha, 2009, Cancer Res., 69, 7926, 10.1158/0008-5472.CAN-08-4900 · DOI · Paper page
  27. Galanzha, 2009, J. Biophotonics, 2, 725, 10.1002/jbio.200910078 · DOI · Paper page
  28. Shashkov, 2010, Opt. Exp., 18, 6929, 10.1364/OE.18.006929 · DOI
  29. Nedosekin, 2010, Opt. Exp., 18, 8605, 10.1364/OE.18.008605 · DOI
  30. Nedosekin, 2011, Cytometry A., 79A, 55
  31. Galanzha, 2011, Cytometry A., 79A, 746, 10.1002/cyto.a.21133 · doi:10.1002/cyto.a.21133
  32. Galanzha, 2011, Cytometry A., 79A, 814, 10.1002/cyto.a.21106 · DOI
  33. Nedosekin, 2011, Cytometry A., 79A, 825, 10.1002/cyto.a.21102 · DOI
  34. Proskurnin, 2011, Cytometry A., 79A, 834, 10.1002/cyto.a.21127 · doi:10.1002/cyto.a.21127
  35. De la Zerda, 2011, Contrast Media Mol. Imaging, 6, 346, 10.1002/cmmi.455 · DOI
  36. Sarimollaoglu, 2011, Opt. Lett., 36, 4086, 10.1364/OL.36.004086 · DOI
  37. Zharov, 2011, Nat. Photonics, 5, 110, 10.1038/nphoton.2010.280 · DOI · Paper page
  38. D.A. Nedosekin, M. Sarimollaogl, E.I. Galanzha, R. Sawant, et al., J. Biophotonics, in press.
  39. Bell, 1880, Am. J. Sci., 20, 305, 10.2475/ajs.s3-20.118.305 · DOI · Paper page
  40. Wang, 2009, Nat. Photon, 3, 503, 10.1038/nphoton.2009.157 · DOI · Paper page
  41. Rasansky, 2009, Nat. Photon., 3, 412, 10.1038/nphoton.2009.98 · DOI · Paper page
  42. Emelianov, 2009, Phys. Today, 2, 34, 10.1063/1.3141939 · doi:10.1063/1.3141939
  43. Beard, 2011, Interface Focus, 1, 602, 10.1098/rsfs.2011.0028 · DOI · Paper page
  44. Novak, 2004, Opt. Lett., 29, 7779, 10.1364/OL.29.000077 · DOI · Paper page
  45. He, 2007, Proc. Natl. Acad. Sci. USA, 104, 1176011765, 10.1073/pnas.0703875104 · DOI · Paper page
  46. Tkaczyk, 2008, Opt. Commun., 281, 888894, 10.1016/j.optcom.2007.10.106 · DOI
  47. Tkaczyk, 2011, Cytometry A, 79, 775, 10.1002/cyto.a.21110 · DOI
  48. Zharov, 2005, J. Sel. Topics Quant. Electron., 11, 733, 10.1109/JSTQE.2005.857382 · DOI
  49. Nedosekin, 2012, Biophys. J., 102, 672, 10.1016/j.bpj.2011.12.035 · DOI
  50. Zharov, 2006, J. Biomed. Opt., 11, 064034, 10.1117/1.2405349 · doi:10.1117/1.2405349
  51. Yu, 2011, J. Cell Biol., 192, 373, 10.1083/jcb.201010021 · DOI · Paper page
  52. Zharov, 2005, J. Nanomed., 1, 326, 10.1016/j.nano.2005.10.006 · DOI · Paper page
  53. Pamme, 2006, Lab Chip, 6, 24, 10.1039/B513005K · DOI · Paper page
  54. Nakshatri, 2009, Curr. Stem Cell Res. Ther., 4, 50, 10.2174/157488809787169110 · DOI
  55. Galanzha, 2011, J. Blood Lymph, 1, 1, 10.4172/2165-7831.1000e104 · doi:10.4172/2165-7831.1000e104
  56. C.L. Weston, M. J Glantz, J. R Connor, Fluids Barriers CNS 8(1) (2011) 14. · DOI
  57. Patel, 2011, Oncotarget, 10, 752, 10.18632/oncotarget.336 · DOI
  58. Zharov, 2006, Biophys. J., 90, 619, 10.1529/biophysj.105.061895 · DOI · Paper page
  59. Kim, 2007, Laser Surg. Med., 39, 622, 10.1002/lsm.20534 · DOI
  60. Jurasz, 2004, Br. J. Pharmacol., 143, 819, 10.1038/sj.bjp.0706013 · DOI · Paper page
  61. Agnelli, 2004, Circulation, 110, IV4
  62. Khodakovskaya, 2011, Proc. Natl. Acad. Sci. USA, 108, 1028, 10.1073/pnas.1008856108 · DOI · Paper page
  63. Brusnichkin, 2009, Moscow Univ. Chem. Bull., 64, 45, 10.3103/S002713140901009X · doi:10.3103/s002713140901009x
  64. Zharov, 2006, SPIE Newsroom
  65. E. Galanzha, E.I. Shashkov, M. Sarimollaoglu, K.E. Beenken, A. Basnakian, J.-W. Kim, M. Shirtliff, M.S. Smeltzer, V.P. Zharov, In vivo magnetic enrichment, photoacoustic diagnosis and photothermal purging of infected blood using multifunctional gold and magnetic nanoparticles. PloS ONE, in press.

Cited by

Metadata

Authors
Galanzha, E. I., & Zharov, V. P.
Venue
Methods
Publisher
Elsevier BV
Published
2012-07
Volume
57
Issue
3
Pages
280-296
ISSN
1046-2023 (ISSN-L)
OpenAlex
W2007499047
Cited by
159
References
0
FWCI
7.85
Type
journal article
Language
en
Open access
green
Funders
  • National Science Foundation (DBI-0852737, W81XWH-11-1-0123, W81XWH-11-1-0129, W88XWH-10-2-0130, R01CA131164, R01EB000873, R01EB009230, R21CA139373)
  • National Institutes of Health (DBI-0852737, W81XWH-11-1-0123, W81XWH-11-1-0129, W88XWH-10-2-0130, R01CA131164, R01EB000873, R01EB009230, R21CA139373)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.