Photoacoustic flow cytometry
Open accessThe DOI matches its Crossref record.
Abstract
Conventional flow cytometry using scattering and fluorescent detection methods has been a fundamental tool of biological discoveries for many years. Invasive extraction of cells from a living organism, however, may lead to changes in cell properties and prevents the long-term study of cells in their native environment. Here, we summarize recent advances of new generation flow cytometry for in vivo noninvasive label-free or targeted detection of cells in blood, lymph, bone, cerebral and plant vasculatures using photoacoustic (PA) detection techniques, multispectral high-pulse-repetition-rate lasers, tunable ultrasharp (up to 0.8 nm) rainbow plasmonic nanoprobes, positive and negative PA contrasts, in vivo magnetic enrichment, time-of-flight cell velocity measurement, PA spectral analysis, and integration of PA, photothermal (PT), fluorescent, and Raman methods. Unique applications of this tool are reviewed with a focus on ultrasensitive detection of normal blood cells at different functional states (e.g., apoptotic and necrotic) and rare abnormal cells including circulating tumor cells (CTCs), cancer stem cells, pathogens, clots, sickle cells as well as pharmokinetics of nanoparticles, dyes, microbubbles and drug nanocarriers. Using this tool we discovered that palpation, biopsy, or surgery can enhance CTC release from primary tumors, increasing the risk of metastasis. The novel fluctuation flow cytometry provided the opportunity for the dynamic study of blood rheology including red blood cell aggregation and clot formation in different medical conditions (e.g., blood disorders, cancer, or surgery). Theranostics, as a combination of PA diagnosis and PT nanobubble-amplified multiplex therapy, was used for eradication of CTCs, purging of infected blood, and thrombolysis of clots using PA guidance to control therapy efficiency. In vivo flow cytometry using a portable fiber-based devices can provide a breakthrough platform for early diagnosis of cancer, infection and cardiovascular disorders with a potential to inhibit, if not prevent, metastasis, sepsis, and strokes or heart attack by well-timed personalized therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 65
- H.M. Shapiro, Practical Flow Cytometry, fourth ed., Wiley-Liss, New York, 2003. · DOI · Paper page
- Tuchin, 2011, Cytometry A, 79A, 737, 10.1002/cyto.a.21143 · doi:10.1002/cyto.a.21143
- Zharov, 2004, Proc. SPIE, 5320, 256
- Galanzha, 2004, Proc. SPIE, 5474, 204, 10.1117/12.578915 · doi:10.1117/12.578915
- Galanzha, 2005, Lymphology, 38, 181
- Galanzha, 2005, J. Biomed. Opt., 10, 54018, 10.1117/1.2060567 · doi:10.1117/1.2060567
- Zharov, 2005, Opt. Lett., 30, 628, 10.1364/OL.30.000628 · doi:10.1364/ol.30.000628
- Zharov, 2005, J. Biomed. Opt., 10, 51502, 10.1117/1.2070167 · doi:10.1117/1.2070167
- Zharov, 2006, J. Cell. Biochem., 97, 916, 10.1002/jcb.20766 · doi:10.1002/jcb.20766
- Zharov, 2006, Opt. Lett., 31, 3623, 10.1364/OL.31.003623 · DOI · Paper page
- Zharov, 2006, J. Biomed. Opt., 11, 054034, 10.1117/1.2355666 · doi:10.1117/1.2355666
- Zharov, 2006, Proc. SPIE, 6085, 10
- Zharov, 2007, Cytometry A, 71A, 191, 10.1002/cyto.a.20384 · doi:10.1002/cyto.a.20384
- Zharov, 2007, J. Biomed. Opt., 12, 0551503, 10.1117/1.2793746 · DOI · Paper page
- Galanzha, 2007, Lymphat. Res. Biol., 5, 1127, 10.1089/lrb.2007.5103 · doi:10.1089/lrb.2007.5103
- Galanzha, 2007, World J. Gastroenterol., 13, 192218, 10.3748/wjg.v13.i2.192 · doi:10.3748/wjg.v13.i2.192
- V. Kalchenko, A. Harmelin, I. Fine, V. Zharov, et al., Proc. SPIE 6436 (2007) 64360. · doi:10.1117/12.716636
- Kalchenko, 2007, J. Biomed. Opt., 12, 052002-1-4, 10.1117/1.2778695 · doi:10.1117/1.2778695
- Galanzha, 2008, Cytometry A, 73A, 884, 10.1002/cyto.a.20587 · DOI
- Olszewski, 2008, Cytometry A, 73A, 1111, 10.1002/cyto.a.20654 · doi:10.1002/cyto.a.20654
- Galanzha, 2009, J. Biophotonics, 2, 528, 10.1002/jbio.200910046 · DOI
- Tanev, 2009, J. Biophotonics, 2, 505520, 10.1002/jbio.200910039 · doi:10.1002/jbio.200910039
- Kim, 2009, Nat. Nanotechnol., 4, 688, 10.1038/nnano.2009.231 · DOI · Paper page
- Galanzha, 2009, Nat. Nanotechnol., 4, 855, 10.1038/nnano.2009.333 · DOI · Paper page
- Biris, 2009, J. Biomed. Opt., 14, 021006, 10.1117/1.3119145 · DOI
- Galanzha, 2009, Cancer Res., 69, 7926, 10.1158/0008-5472.CAN-08-4900 · DOI · Paper page
- Galanzha, 2009, J. Biophotonics, 2, 725, 10.1002/jbio.200910078 · DOI · Paper page
- Shashkov, 2010, Opt. Exp., 18, 6929, 10.1364/OE.18.006929 · DOI
- Nedosekin, 2010, Opt. Exp., 18, 8605, 10.1364/OE.18.008605 · DOI
- Nedosekin, 2011, Cytometry A., 79A, 55
- Galanzha, 2011, Cytometry A., 79A, 746, 10.1002/cyto.a.21133 · doi:10.1002/cyto.a.21133
- Galanzha, 2011, Cytometry A., 79A, 814, 10.1002/cyto.a.21106 · DOI
- Nedosekin, 2011, Cytometry A., 79A, 825, 10.1002/cyto.a.21102 · DOI
- Proskurnin, 2011, Cytometry A., 79A, 834, 10.1002/cyto.a.21127 · doi:10.1002/cyto.a.21127
- De la Zerda, 2011, Contrast Media Mol. Imaging, 6, 346, 10.1002/cmmi.455 · DOI
- Sarimollaoglu, 2011, Opt. Lett., 36, 4086, 10.1364/OL.36.004086 · DOI
- Zharov, 2011, Nat. Photonics, 5, 110, 10.1038/nphoton.2010.280 · DOI · Paper page
- D.A. Nedosekin, M. Sarimollaogl, E.I. Galanzha, R. Sawant, et al., J. Biophotonics, in press.
- Bell, 1880, Am. J. Sci., 20, 305, 10.2475/ajs.s3-20.118.305 · DOI · Paper page
- Wang, 2009, Nat. Photon, 3, 503, 10.1038/nphoton.2009.157 · DOI · Paper page
- Rasansky, 2009, Nat. Photon., 3, 412, 10.1038/nphoton.2009.98 · DOI · Paper page
- Emelianov, 2009, Phys. Today, 2, 34, 10.1063/1.3141939 · doi:10.1063/1.3141939
- Beard, 2011, Interface Focus, 1, 602, 10.1098/rsfs.2011.0028 · DOI · Paper page
- Novak, 2004, Opt. Lett., 29, 7779, 10.1364/OL.29.000077 · DOI · Paper page
- He, 2007, Proc. Natl. Acad. Sci. USA, 104, 1176011765, 10.1073/pnas.0703875104 · DOI · Paper page
- Tkaczyk, 2008, Opt. Commun., 281, 888894, 10.1016/j.optcom.2007.10.106 · DOI
- Tkaczyk, 2011, Cytometry A, 79, 775, 10.1002/cyto.a.21110 · DOI
- Zharov, 2005, J. Sel. Topics Quant. Electron., 11, 733, 10.1109/JSTQE.2005.857382 · DOI
- Nedosekin, 2012, Biophys. J., 102, 672, 10.1016/j.bpj.2011.12.035 · DOI
- Zharov, 2006, J. Biomed. Opt., 11, 064034, 10.1117/1.2405349 · doi:10.1117/1.2405349
- Yu, 2011, J. Cell Biol., 192, 373, 10.1083/jcb.201010021 · DOI · Paper page
- Zharov, 2005, J. Nanomed., 1, 326, 10.1016/j.nano.2005.10.006 · DOI · Paper page
- Pamme, 2006, Lab Chip, 6, 24, 10.1039/B513005K · DOI · Paper page
- Nakshatri, 2009, Curr. Stem Cell Res. Ther., 4, 50, 10.2174/157488809787169110 · DOI
- Galanzha, 2011, J. Blood Lymph, 1, 1, 10.4172/2165-7831.1000e104 · doi:10.4172/2165-7831.1000e104
- C.L. Weston, M. J Glantz, J. R Connor, Fluids Barriers CNS 8(1) (2011) 14. · DOI
- Patel, 2011, Oncotarget, 10, 752, 10.18632/oncotarget.336 · DOI
- Zharov, 2006, Biophys. J., 90, 619, 10.1529/biophysj.105.061895 · DOI · Paper page
- Kim, 2007, Laser Surg. Med., 39, 622, 10.1002/lsm.20534 · DOI
- Jurasz, 2004, Br. J. Pharmacol., 143, 819, 10.1038/sj.bjp.0706013 · DOI · Paper page
- Agnelli, 2004, Circulation, 110, IV4
- Khodakovskaya, 2011, Proc. Natl. Acad. Sci. USA, 108, 1028, 10.1073/pnas.1008856108 · DOI · Paper page
- Brusnichkin, 2009, Moscow Univ. Chem. Bull., 64, 45, 10.3103/S002713140901009X · doi:10.3103/s002713140901009x
- Zharov, 2006, SPIE Newsroom
- E. Galanzha, E.I. Shashkov, M. Sarimollaoglu, K.E. Beenken, A. Basnakian, J.-W. Kim, M. Shirtliff, M.S. Smeltzer, V.P. Zharov, In vivo magnetic enrichment, photoacoustic diagnosis and photothermal purging of infected blood using multifunctional gold and magnetic nanoparticles. PloS ONE, in press.
Cited by
Multiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells
Farooq, T., Wu, X., Yan, S., & Fang, H. (2024) · Biosensors · doi:10.3390/bios14080397 · Cited by 1
“Photoacoustics has been implemented in many versatile applications, such as the characterization of photoacoustic and fluorescence properties of living cells [3], environmental monitoring [4], and flow cytometry [5–9].”
Method
Metadata
- Authors
- Galanzha, E. I., & Zharov, V. P.
- Venue
- Methods
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 57
- Issue
- 3
- Pages
- 280-296
- ISSN
- 1046-2023 (ISSN-L)
- OpenAlex
- W2007499047
- Cited by
- 159
- References
- 0
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Funders
- National Science Foundation (DBI-0852737, W81XWH-11-1-0123, W81XWH-11-1-0129, W88XWH-10-2-0130, R01CA131164, R01EB000873, R01EB009230, R21CA139373)
- National Institutes of Health (DBI-0852737, W81XWH-11-1-0123, W81XWH-11-1-0129, W88XWH-10-2-0130, R01CA131164, R01EB000873, R01EB009230, R21CA139373)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.