The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
In vivo quantitation of rare circulating tumor cells by multiphoton intravital flow cytometry
Open accessAbstract
Quantitation of circulating tumor cells (CTCs) constitutes an emerging tool for the diagnosis and staging of cancer, assessment of response to therapy, and evaluation of residual disease after surgery. Unfortunately, no existing technology has the sensitivity to measure the low numbers of tumor cells (<1 CTC per ml of whole blood) that characterize minimal levels of disease. We present a method, intravital flow cytometry, that noninvasively counts rare CTCs in vivo as they flow through the peripheral vasculature. The method involves i.v. injection of a tumor-specific fluorescent ligand followed by multiphoton fluorescence imaging of superficial blood vessels to quantitate the flowing CTCs. Studies in mice with metastatic tumors demonstrate that CTCs can be quantitated weeks before metastatic disease is detected by other means. Analysis of whole blood samples from cancer patients further establishes that human CTCs can be selectively labeled and quantitated when present at ≈2 CTCs per ml, opening opportunities for earlier assessment of metastatic disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Parker, N., Turk, M. J., Westrick, E., Lewis, J. D., Low, P. S., & Leamon, C. P. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2004.12.026 · Cited by 1,197
Self-citationCirculating Tumor Cells: A Novel Prognostic Factor for Newly Diagnosed Metastatic Breast Cancer
Cristofanilli, M., Hayes, D. F., Budd, G. T., Ellis, M. J., Stopeck, A., Reuben, J. M., Doyle, G. V., Matera, J., Allard, W. J., Miller, M. C., et al. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.08.140 · Cited by 1,135
The Effect of Folic Acid Fortification on Plasma Folate and Total Homocysteine Concentrations
Jacques, P. F., Selhub, J., Bostom, A. G., Wilson, P. W. F., & Rosenberg, I. H. (1999) · New England Journal of Medicine · doi:10.1056/nejm199905133401901 · Cited by 1,117
Two-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Distribution of the folate receptor GP38 in normal and malignant cell lines and tissues.
Weitman, S. D., Lark, R. H., Coney, L. R., Fort, D. W., Frasca, V., Zurawski, V. R., & Kamen, B. A. (1992) · PubMed · Cited by 1,011
Ross, J. F., Chaudhuri, P. K., & Ratnam, M. (1994) · Cancer · doi:10.1002/1097-0142(19940501)73:9<2432::aid-cncr2820730929>3.0.co;2-s · Cited by 891
Morris, M. S., Jacques, P. F., Rosenberg, I. H., & Selhub, J. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.1.193 · Cited by 608
Cited by
Imaging in the era of molecular oncology
Weissleder, R., & Pittet, M. J. (2008) · Nature · doi:10.1038/nature06917 · Cited by 2,364
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Detection, clinical relevance and specific biological properties of disseminating tumour cells
Pantel, K., Brakenhoff, R. H., & Brandt, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2375 · Cited by 1,118
Anisotropic Gold Nanoparticles: Synthesis, Properties, Applications, and Toxicity
Li, N., Zhao, P., & Astruc, D. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201300441 · Cited by 962
Golden carbon nanotubes as multimodal photoacoustic and photothermal high-contrast molecular agents
Kim, J.-W., Galanzha, E. I., Shashkov, E. V., Moon, H.-M., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.231 · Cited by 710
Metadata
- Authors
- He, W., Wang, H., Hartmann, L. C., Cheng, J.-X., & Low, P. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-07-10
- Volume
- 104
- Issue
- 28
- Pages
- 11760-11765
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2017495608
- Cited by
- 292
- References
- 27
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo quantitation of rare circulating tumor cells by multiphoton intravital flow cytometry. https://app.cochat.ai/papers/10.1073/pnas.0703875104
- The paper
- He, W., Wang, H., Hartmann, L. C., Cheng, J.-X., & Low, P. S. (2007). In vivo quantitation of rare circulating tumor cells by multiphoton intravital flow cytometry. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0703875104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.