Accuracy of an automatic and patient-triggered long-term solid memory ambulatory cardiac event recorder
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This study evaluated the R-Test Evolution, a new type of cardiac event recorder bearing both patient-triggered and automatic capabilities. Its 7-day automatic arrhythmia analysis showed promising clinical advantages, especially when investigating patients with unexplained rare events such as syncope, feeling of weakness or faintness, palpitations, stroke, or in patients inconsistent in their use of patient-triggered recordings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Only few data are available about its efficacy and clinical relevance in unselected groups of ambulatory patients. 8, 9”
In the citing paper
“In the same study, while exclusively using the automatic mode in 35 patients, 6 (17%) of these patients revealed abnormal ECG findings that occurred beyond the first 24-h period.”
In the citing paper
“tion, found that the sensitivity of the R-Test Evolution, compared with a conventional Holter ECG, was 100% in detecting pauses, bradycardia, atrial fibrillation, and episodes of ventricular bigeminus; 70 to 82% in detecting supraventricular tachycardias; and 86% in detecting ventricular tachycardias. 9”
Citations
Cites
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Evaluation and Management of the Patient With Syncope
Kapoor, W. N. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490180085031 · Cited by 229
Brown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
Kennedy, H. L., Chandra, V., Sayther, K. L., & Caralis, D. G. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90677-x · Cited by 84
Utility of Patient-Activated Cardiac Event Recorders in General Clinical Practice
Zimetbaum, P., Kim, K. Y., Ho, K. K. L., Zebede, J., Josephson, M. E., & Goldberger, A. L. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00766-7 · Cited by 77
Reiffel, J. A., Schulhof, E., Joseph, B., Severance, E., Wyndus, P., & McNamara, A. (1991) · Journal of Electrocardiology · doi:10.1016/0022-0736(91)90007-9 · Cited by 36
Ambulatory (Holter) Electrocardiography Technology
Kennedy, H. L. (1992) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30218-2 · Cited by 35
Recurrent syncope of unknown origin diagnosed by ambulatory continuous loop ECG recording
Linzer, M., Prystowsky, E. N., Brunetti, L. L., Varia, I., & German, L. D. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90757-0 · Cited by 20
Research works printed but not linked: 1
- Prystowsky, 1991, Diagnostic evaluation and treatment strategies for patients at risk for serious cardiac arrhythmias. Part 1: Syncope of unknown origin, Mod Concepts Cardiovasc Dis, 60, 49
Cited by
Jabaudon, D., Sztajzel, J., Sievert, K., Landis, T., & Sztajzel, R. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Da Costa, A., Thévenin, J., Roche, F., Romeyer-Bouchard, C., Abdellaoui, L., Messier, M., Denis, L., Faure, E., Gonthier, R., Kruszynski, G., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.638395 · Cited by 140
Self-citationBarthélémy, J., Féasson‐Gérard, S., Garnier, P., Gaspoz, J., Costa, A. D., Michel, D., & Roche, F. (2003) · Annals of Noninvasive Electrocardiology · doi:10.1046/j.1542-474x.2003.08305.x · Cited by 105
Self-citationROCHE, F., GASPOZ, J., DA COSTA, A., ISAAZ, K., DUVERNEY, D., PICHOT, V., COSTES, F., LACOUR, J., & BARTHÉLÉMY, J. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01587.x · Cited by 101
Self-citationDa Costa, A., Defaye, P., Romeyer-Bouchard, C., Roche, F., Dauphinot, V., Deharo, J.-C., Jacon, P., Lamaison, D., Bathélemy, J.-C., Isaaz, K., et al. (2013) · Archives of Cardiovascular Diseases · doi:10.1016/j.acvd.2012.12.002 · Cited by 63
Self-citationSCHUCHERT, A., MAAS, R., KRETZSCHMAR, C., BEHRENS, G., KRATZMANN, I., & MEINERTZ, T. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00277.x · Cited by 62
A Review of Atrial Fibrillation Detection Methods as a Service
Faust, O., Ciaccio, E. J., & Acharya, U. R. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17093093 · Cited by 62
“The consistency with which the device is used varies from patient to patient, dependent on their mental capability [175].”
BackgroundBalmelli, N., Naegeli, B., & Bertel, O. (2003) · Clinical Cardiology · doi:10.1002/clc.4960260405 · Cited by 35
Safety and efficacy of the nMARQ catheter for paroxysmal and persistent atrial fibrillation
Vurma, M., Dang, L., Rocca, H. B., Sütsch, G., Jost, C. H. A., Duru, F., & Scharf, C. (2016) · EP Europace · doi:10.1093/europace/euw048 · Cited by 34
“An external loop recorder was also allowed, because the automated AF detection algorithm reliably detects AF.(7) In patients presenting with persistent AF, documentation on a 12-lead ECG was accepted.”
InfluentialTivig, C., Dang, L., Rocca, H. B., Özcan, S., Duru, F., & Scharf, C. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.12.010 · Cited by 30
“loop recorder has been shown to reliably detect AF episodes by an automatic detection algorithm (N25% variation of RR Intervals) [10].”
MethodTargeting autonomic nervous system as a biomarker of well-ageing in the prevention of stroke
Barthélemy, J., Pichot, V., Hupin, D., Berger, M., Celle, S., Mouhli, L., Bäck, M., Lacour, J.-R., & Roche, F. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.969352 · Cited by 27
Self-citationCosta, A. D., Gulian, J.-L., Romeyer-Bouchard, C., Messier, M., Zarqane, N., Samuel, B., Khiel, A., & Isaaz, K. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.05.025 · Cited by 25
“Diagnostic evaluation with extended monitoring was not performed and these devices may be helpful in patients whose initial test yielded false negative results after a first syncopal episode [29].”
BackgroundSelf-citationKo, J. K., Ryu, S. J., Ban, J., Kim, Y. H., & Park, I. S. (2004) · Japanese Heart Journal · doi:10.1536/jhj.45.63 · Cited by 18
Antiarrhythmic drug initiation in patients with atrial fibrillation
Pinski, S. L., & Helguera, M. E. (1999) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(99)70010-1 · Cited by 14
Relevance of Monitoring Atrial Fibrillation in Clinical Practice
Lewalter, T., & Boriani, G. (2012) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2012.1.54 · Cited by 14
Barrionuevo, J. D. D. A., Barón‐Esquivias, G., Martínez, Á. M., Cornejo, J. B., Rodríguez, A. N., Carrasco, A. P., Cabezas, J. J. S., Cayuela, A., & Fernández, J. M. C. (2002) · Revista Española de Cardiología · doi:10.1016/s0300-8932(02)76569-x · Cited by 11
Assessment of an ECG event recorder in healthy dogs in a hospital environment
Eastwood, J. M., & Elwood, C. M. (2003) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2003.tb00138.x · Cited by 10
Schuchert, A., Behrens, G., & Meinertz, T. (2002) · Zeitschrift für Kardiologie · doi:10.1007/s392-002-8373-4 · Cited by 12
“ventrikulären Tachyarrhythmien dokumentiert, wobei diese Patienten auch mit Synkopen untersucht haben (4, 8).”
BackgroundDiagnosis effectiveness of arrhythmia with R-test electrocardiogram in old fallers
Midttun, M. (2011) · European Geriatric Medicine · doi:10.1016/j.eurger.2011.07.005 · Cited by 3
Initial Results of Linear Duty‐Cycled Radiofrequency for Atypical Flutter and Atrial Tachycardia
Naegeli, B., Dang, L., Boll, S., Tivig, C., & Scharf, C. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03118.x · Cited by 1
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 3
“Patienten keine effiziente Diagnostik erfolgen konnte [30, 41, 42].”
Use of an event recorder in the decision for pacemaker implantation in a child with syncope
Verhaaren, H. A., Vanakker, O. M., Coster, R. N. V., Wolf, D. D., François, K., & Matthys, D. (2002) · European Journal of Pediatrics · doi:10.1007/s00431-002-0928-6 · Cited by 2
“Newer devices, such as the R-Test Evolution (Novacor), feature both automatic and patient-triggered recordings and allow up to 7 days of monitoring and can be used in children [9].”
BackgroundMethodInfluentialNichtinvasive Untersuchungsmethoden bei Vorhofflimmern/Vorhofflattern
Andresen, D., Brüggemann, T., Ehlers, C., & Wiedemann, M. (2007) · Steinkopff eBooks · doi:10.1007/978-3-7985-1748-6_6
Harańczyk, M., Konieczyńska, M., & Płazak, W. (2017) · Current research. Cardiology · doi:10.4172/2368-0512.1000097
“In the case of loss of consciousness, when the time of regaining consciousness exceeds the programmed loop-time, it is highly unlikely to record arrhythmia (14,15).”
BackgroundNichtinvasive Untersuchungsmethoden bei Vorhofflimmern/Vorhofflattern
Andresen, D., Brüggemann, T., Ehlers, C., & Wiedemann, M. (2000) · Steinkopff eBooks · doi:10.1007/978-3-662-13383-5_4
Utility of an automatic and patient-triggered cardiac event recorder: experience in children
Elkıran, Ö., & Öncül, M. (2026) · BMC Pediatrics · doi:10.1186/s12887-026-07447-5
“With the development of recent event recorders which can also detect arrhythmia automatically, this problem has been overcome [15, 16].”
Metadata
- Authors
- Roche, F., Gaspoz, J.-M., Pichot, V., Costes, F., Isaaz, K., Ferron, C., Roche, C., Geyssant, A., Lacour, J.-R., & Barthélémy, J.-C.
- Affiliations
- Lyon 1 Université (FR)
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1997-10
- Volume
- 80
- Issue
- 8
- Pages
- 1095-1098
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W1978247623
- Semantic Scholar
- 0a258ae371b5a93ea91245980d7ddd69ce1361f7
- Cited by
- 26
- References
- 13
- Citations by year
- 2026: 1 · 2022: 1 · 2020: 1 · 2017: 1 · 2016: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- automatic arrhythmia detection, diagnostic accuracy, syncope, palpitations, stroke
- MeSH terms
- Arrhythmias, Cardiac, Evaluation Studies as Topic, Humans, Sensitivity and Specificity, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.