Blood flow and the degree of shunting through the ductus venosus in the human fetus
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circulatory Changes during Growth in the Fetal Lamb
RUDOLPH, A. M., & HEYMANN, M. A. (1970) · Circulation Research · doi:10.1161/01.res.26.3.289 · Cited by 487
How to construct ‘normal ranges’ for fetal variables
Royston, P., & Wright, E. M. (1998) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1998.11010030.x · Cited by 475
Hecher, K., Campbell, S., Doyle, P., Harrington, K., & Nicolaides, K. (1995) · Circulation · doi:10.1161/01.cir.91.1.129 · Cited by 444
Charts of fetal size: 1. Methodology
Altman, D. G., & Chitty, L. S. (1994) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13006.x · Cited by 369
Distribution of the circulation in the normal and asphyxiated fetal primate
Behrman, R. E., Lees, M. H., Peterson, E. N., de Lannoy, C. W., & Seeds, A. E. (1970) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(70)90341-8 · Cited by 357
Rasanen, J., Wood, D. C., Weiner, S., Ludomirski, A., & Huhta, J. C. (1996) · Circulation · doi:10.1161/01.cir.94.5.1068 · Cited by 347
Ultrasonographic velocimetry of the fetal ductus venosus
Kiserud, T., Eik-Nes, S. H., Blaas, H.-G. K., & Hellevik, L. R. (1991) · The Lancet · doi:10.1016/0140-6736(91)92720-m · Cited by 304
Self-citationDuctus venosus blood velocity and the umbilical circulation in the seriously growth‐retarded fetus
Kiserud, T., Eik‐Nes, S. H., Blaas, H. ‐., Hellevik, L. R., & Simensen, B. (1994) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1994.04020109.x · Cited by 235
Self-citationPreferential streaming of ductus venosus blood to the brain and heart in fetal lambs
Edelstone, D. I., & Rudolph, A. M. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.6.h724 · Cited by 189
Chitty, L., & Altman, D. (1994) · BMUS Bulletin · doi:10.1177/1742271x9400200404 · Cited by 175
Cited by
The pregnant sheep as a model for human pregnancy
Barry, J. S., & Anthony, R. V. (2008) · Theriogenology · doi:10.1016/j.theriogenology.2007.09.021 · Cited by 315
Fetal cardiac output, distribution to the placenta and impact of placental compromise
Kiserud, T., Ebbing, C., Kessler, J., & Rasmussen, S. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2832 · Cited by 276
Self-citationFrias, A. E., Morgan, T. K., Evans, A. E., Rasanen, J., Oh, K. Y., Thornburg, K. L., & Grove, K. L. (2011) · Endocrinology · doi:10.1210/en.2010-1332 · Cited by 268
“Thequantitative estimationofblood flowon the fetal side of the placenta, the placental volume blood flow (cQUV) is reduced in pregnancies complicated by intrauterine growth restriction (19, 20).”
BackgroundKiserud, T., & Acharya, G. (2004) · Prenatal Diagnosis · doi:10.1002/pd.1062 · Cited by 257
Self-citationPhysiology of the fetal circulation
Kiserud, T. (2005) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2005.08.007 · Cited by 253
Self-citationZika virus infection in pregnant rhesus macaques causes placental dysfunction and immunopathology
Hirsch, A. J., Roberts, V. H. J., Grigsby, P. L., Haese, N., Schabel, M. C., Wang, X., Lo, J. O., Liu, Z., Kroenke, C. D., Smith, J. L., et al. (2018) · Nature Communications · doi:10.1038/s41467-017-02499-9 · Cited by 203
Yagel, S., Kivilevitch, Z., Cohen, S. M., Valsky, D. V., Messing, B., Shen, O., & Achiron, R. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7622 · Cited by 129
Caradeux, J., Martinez-Portilla, R. J., Basuki, T. R., Kiserud, T., & Figueras, F. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.11.566 · Cited by 115
Self-citationPregnancy-related maternal physiological adaptations and fetal chemical exposure
Vinnars, M.-T., Bixo, M., & Damdimopoulou, P. (2023) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2023.112064 · Cited by 32
Role of ultrasound in the management of diabetes in pregnancy
Ahmed, B., Abushama, M., Khraisheh, M., & Dudenhausen, J. (2015) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2014.971745 · Cited by 24
“Liver is the 4th preferential organ besides brain, heart and the adrenals to be spared in hypovolemic/hypoxemic conditions [81].”
BackgroundCardiac output and blood flow volume redistribution during acute maternal hypoxia in fetal sheep
Tchirikov, M., Strohner, M., & Scholz, A. (2010) · Journal of Perinatal Medicine · doi:10.1515/jpm.2010.053 · Cited by 14
Metadata
- Authors
- Kiserud, T., Rasmussen, S., & Skulstad, S.
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 2000-01
- Volume
- 182
- Issue
- 1
- Pages
- 147-153
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W2154402005
- Cited by
- 307
- References
- 17
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.