Living, autologous pulmonary artery conduits tissue engineered from human umbilical cord cells

Open access
Hoerstrup, Simon P, Kadner, Alexander, Breymann, Christian, Maurus, Christine F, Guenter, Christina I, Sodian, Ralf, Visjager, Jeroen F, Zund, Gregor, Turina, Marko I · 2002 · The Annals of Thoracic Surgery
Cited by 164

The DOI matches its Crossref record.

Abstract

BACKGROUND: Tissue engineering represents a promising approach to in vitro creation of living, autologous replacements with the potential to grow, repair, and remodel. Particularly in a congenital operation, there is a substantial need for such implantation materials. We previously demonstrated fabrication of completely autologous, functional heart valves on the basis of peripheral vascular cells. Presently the feasibility of creating pulmonary artery conduits from human umbilical cord cells was investigated. METHODS: Human umbilical cord cells were harvested and expanded in culture. Pulmonary conduits fabricated from rapidly bioabsorbable polymers were seeded with human umbilical cord cells and grown in vitro in a pulse duplicator bioreactor. Morphologic characterization of the generated neo-tissues included histology, transmission, and scanning electron microscopy. Characterization of extracellular matrix was comprised of immunohistochemistry. Extracellular matrix protein content and cell proliferation were quantified by biochemical assays. Biomechanical testing was performed using stress-strain and burst-stress tests. RESULTS: Histology of the conduits revealed viable, layered tissue and extracellular matrix formation with glycosaminoglycans and collagens I and III. Cells stained positive for vimentin and alpha-smooth muscle actin. Scanning electron microscopy showed confluent, homogenous tissue surfaces. Transmission electron microscopy demonstrated elements typical of viable myofibroblasts, such as collagen, fibrils, and elastin. Extracellular matrix proteins were significantly lower compared with native tissue; the cell content was increased. The mechanical strength of the pulsed constructs was comparable with native tissue; the static controls were significantly weaker. CONCLUSIONS: In vitro fabrication of tissue-engineered human pulmonary conduits was feasible utilizing human umbilical cord cells and a biomimetic culture environment. Morphologic and mechanical features approximated human pulmonary artery. Human umbilical cord cells demonstrated excellent growth properties representing a new, readily available cell source for tissue engineering without necessitating the sacrifice of intact vascular donor structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0003-4975(02)03649-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hoerstrup, S. P., Kadner, A., Breymann, C., Maurus, C. F., Guenter, C. I., Sodian, R., Visjager, J. F., Zund, G., & Turina, M. I.
Venue
The Annals of Thoracic Surgery
Publisher
Elsevier BV
Published
2002-07
Volume
74
Issue
1
Pages
46-52
ISSN
0003-4975 (ISSN-L)
OpenAlex
W1988066887
Cited by
164
References
0
FWCI
9.68
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.